Chapter 6: Advanced Chassis Setup
6-3
6-3
System Fans
Two 10-cm blower fans provide all the cooling needed for the SuperServer 6013P-
8. It is very important that the chassis top cover is properly installed and making
a good seal in order for the cooling air to circulate properly through the chassis
and cool the components. See Figure 6-2.
System Fan Failure
The fans run at 4200 rpm. If a fan fails, the ambient air temperature in the chassis
will rise and activate the overheat LED on the control panel. Replace any failed
fan immediately with the same type and model. You must power down the
system before replacing a cooling fan (removing the power cord is also recom-
mended as a safety precaution).
Replacing System Cooling Fans
1.
Removing a fan:
Remove the chassis cover. Detach the fan wires from their connection
to the serverboard. Remove the screws that secure the fan to the
chassis and lift the blower fan out.
2.
Installing a new fan:
Replace the failed fan with an identical 10-cm, 12 volt fan (available from
Supermicro: p/n FAN-0066). Install the new fan in its proper place in the
chassis by positioning it on the two mounting posts. Secure the fan to
the chassis with the screws you removed previously, then attach the fan
wires to the connector on the serverboard. Finish by replacing the
chassis cover and power cord and restoring power to the system.
Содержание SuperServer 6013P-8
Страница 1: ...SUPERSERVER 6013P 8 USER SMANUAL 1 1b SUPER...
Страница 5: ...v Preface Notes...
Страница 10: ...SUPERSERVER 6013P 8 User s Manual x Notes...
Страница 18: ...SUPERSERVER 6013P 8 Manual 1 8 Notes...
Страница 64: ...5 28 SUPERSERVER 6013P 8 User s Manual Notes...
Страница 73: ...Chapter 6 Advanced Chassis Setup 6 9 Figure 6 5 Removing Replacing the Power Supply...
Страница 74: ...6 10 SUPERSERVER 6013P 8 Manual Notes...
Страница 102: ...A 6 SUPERSERVER 6013P 8 Manual Notes...
Страница 108: ...B 6 SUPERSERVER 6013P 8 Manual Notes...