background image

Chapter 6: BIOS

101

*If any storage media is detected, the following items will become available for 
configuration:

Add New Boot Option

This feature allows the user to add a new boot option to the boot priority features for your 
system.

Add Boot Option

Use this item to specify the name for the new boot option.

Path for Boot Option

Use this item to enter the path for the new boot option in the format fsx:\path\filename.efi. 

Boot Option File Path

Use this item to specify the file path for the new boot option. 

Create

Use this item to set the name and the file path of the new boot option.

UEFI USB Key Drive BBS Priorities

This feature sets the system boot order of detected devices.

• 

Boot Option #1

USB Key Drive BBS Priorities

This feature sets the system boot order of detected devices. 

• 

Boot Option #1

Содержание SUPERSERVER 5019P-M

Страница 1: ...USER S MANUAL Revision 1 0 SuperServer 5019P M 5019P MR...

Страница 2: ...s operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may c...

Страница 3: ...essary drivers utilities and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities ftp ftp supermicro com Product safety in...

Страница 4: ...Location 17 Rack Precautions 17 Server Precautions 18 Rack Mounting Considerations 18 Ambient Operating Temperature 18 Airflow 18 Mechanical Loading 18 Circuit Overloading 19 Reliable Ground 19 2 3 I...

Страница 5: ...k Module PHM 30 Removing the Processor Heatsink Module PHM from the Motherboard 31 Memory Support and Installation 32 Memory Support 32 DIMM Module Population Sequence 33 DIMM Installation 33 DIMM Rem...

Страница 6: ...on RAID System 57 5 2 Driver Installation 58 5 3 SuperDoctor 5 59 5 4 IPMI 60 Chapter 6 BIOS 6 1 Introduction 61 6 2 Main Setup 62 6 3 Advanced Setup Configurations 64 6 4 Event Logs 90 6 5 IPMI 92 6...

Страница 7: ...V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermic...

Страница 8: ...power outlet nearby Be sure to read the precautions and considerations noted in Appendix B Main Parts List Description Part Number Quantity Air Shroud MCP 310 81305 0B 1 Hard Drive Backplane BPN SAS3...

Страница 9: ...er TDP of up to 165W and 28 cores Socket Type Socket P0 LGA3647 Memory Up to 192GB of RDIMM 384GB of LRDIMM and 768GB of 3DS LRDIMM DDR4 ECC memory with speeds of up to 2666 MHz in six memory slots No...

Страница 10: ...y be illuminated when the system is operating 6 Reset Button The reset button is used to reboot the system 7 Power Button The main power button is used to apply or remove power from the power supply t...

Страница 11: ...Feature Description 1 SATA HDD Hot swap 3 5 SATA hard disk drive 2 DVD Drive Front access DVD drive bay drive is optional 3 Front USB 3 0 and COM Port A front control panel for two USB 3 0 ports and a...

Страница 12: ...P M single 350W Platinum Level power supply 5019P MR dual 400W Platinum Level power supplies 2 I O Backpanel Rear I O ports see Section 4 3 for full details 3 Expansion Card Slot Slot for one expansio...

Страница 13: ...WR NIC2 OH FF RST ON PWR CPU1 SLOT7 PCI E 3 0 X8 CPU1 SLOT6 PCI E 3 0 X16 CPU USB8 9 3 0 USB10 3 0 I SATA4 7 I SATA0 3 USB4 5 USB2 3 CPU1 SLOT4 PCI E 3 0 X16 LAN1 2 F TPF DIMMC1 DIMMB1 DIMMA1 DIMMF1 D...

Страница 14: ...1 FAN6 FANA FANB CPU System Fan Headers IPMI_LAN Dedicated IPMI LAN Port I SATA0 7 S SATA0 3 Intel PCH SATA 3 0 Ports with RAID 0 1 5 10 J18 External RTC Battery Header JD1 4 pin Speaker Header JF1 Fr...

Страница 15: ...CPU PCI E 3 0 x8 Slot SRW3 SRW4 M 2 Mounting Holes S SGPIO1 Serial Link General Purpose I O Header USB0 1 Back Panel Universal Serial Bus USB 2 0 Ports USB2 3 USB4 5 Front Accessible USB 2 0 Headers...

Страница 16: ...VR13 DIMMD1 PCI E X16 DMI3 JPCIE6 PCI E X8 PCI E X16 DMI3 DIMME1 DIMMF1 JPCIE4 NCSI master SPI LAN3 RGRMII PCI E X1 USB 2 0 PCH USB 2 0 x 6 USB 1 0 I SATA RTL8211F RJ45 ESPI Temp Sensor NCT7718W USB...

Страница 17: ...ion Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated Leave eno...

Страница 18: ...in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always keep the front door of the rack and all covers panels on the servers closed...

Страница 19: ...ention should be given to power supply connections other than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit...

Страница 20: ...r stability reasons 1 Position the chassis rail guides at the desired location in the rack keeping the sliding rail guide facing the inside of the rack 2 Screw the assembly securely to the rack using...

Страница 21: ...on both sides you may have to press the locking tabs when inserting See Figure 2 2 3 When the server has been pushed completely into the rack you should hear the locking tabs click Figure 2 1 Installi...

Страница 22: ...ssis four total 1 First determine how far the server will extend out from the front of the rack The chassis should be positioned so that the weight is balanced between front and back 2 Attach the two...

Страница 23: ...the power strip or outlet If your system has more than one power supply remove the AC power cords from all power supply modules 3 Disconnect the power cord s from the power supply modules 3 2 Accessi...

Страница 24: ...se note that the processor and heatsink should be assembled together first to form the Processor Heatsink Module PHM and then install the entire PHM into the CPU socket When you receive a motherboard...

Страница 25: ...essor package carrier used for the CPU Overview of the Processor Socket Assembly The processor socket assembly contains 1 the Intel processor 2 the processor clip 3 the dust cover and 4 the CPU socket...

Страница 26: ...mponent Installation 1 Heatsink 2 Processor Clip 3 Processor Overview of the Processor Heatsink Module PHM The Processor Heatsink Module PHM contains 1 a heatsink 2 a processor clip and 3 the processo...

Страница 27: ...by sliding notch B of the CPU into notch B of the processor clip and sliding notch C of the CPU into notch C of the processor clip 4 Examine all corners of the CPU to ensure that it is properly seated...

Страница 28: ...graphic Note a larger hole and plastic mounting clicks located next to the hollow triangle Also locate another set of mounting clicks and a larger hole at the diagonal corner of the same reverse side...

Страница 29: ...P0 socket and 4 a back plate These components are pre installed on the motherboard before shipping Dusk Cover Socket Pins Remove the dust cover from the CPU socket Do not touch the socket pins Removin...

Страница 30: ...right side up and you will see a triangle marked on the processor clip at the same corner of hollow triangle 3 Carefully align pin 1 the triangle on the the PHM against pin 1 the triangle on the CPU...

Страница 31: ...ng the processor heatsink module PHM unplug power cord from the power outlet 1 Using a T30 Torx bit screwdriver turn the screws on the PHM counterclockwise to loosen them from the socket starting with...

Страница 32: ...GB of 3DS LRDIMM ECC DDR4 2666 memory in six memory slots Refer to the table below for additional memory information Type RDIMM RDIMM RDIMM RDIMM RDIMM 3DS LRDIMM 3DS LRDIMM Ranks Per DIMM and Data Wi...

Страница 33: ...release tabs to the lock positions to secure the DIMM module into the slot DIMM Removal Press both release tabs on the ends of the DIMM module to unlock it Once the DIMM module is loosened remove it f...

Страница 34: ...battery must be replaced only with the same or an equivalent type recommended by the manufacturer CR2032 OR Figure 3 2 Installing the Onboard Battery Motherboard Battery The motherboard uses non vola...

Страница 35: ...es are mounted in drive carriers to simplify their installation and removal from the chassis Both procedures may be done without removing power from the system Removing a Hot Swap Drive Carrier 1 Push...

Страница 36: ...ons the status indicator lights to indicate the status of the drive In non RAID configurations the status indicator remains off See the table below for details Figure 3 4 Removing a Drive Carrier Note...

Страница 37: ...system fan may be added for optimal cooling It is very important that the chassis top cover is installed for the cooling air to circulate properly through the chassis and cool the components Replacin...

Страница 38: ...38 Chapter 3 Maintenance and Component Installation Figure 3 5 Replacing a System Fan Note the figure above is intended to show fan location only The serverboard may differ from that in the 5019P M MR...

Страница 39: ...detach automatically when the module is pulled from the chassis Installing a New Power Supply 1 Replace the failed power module with another power supply module p n PWS 350 1H 2 Simply push the new po...

Страница 40: ...Contact Information in the Preface 1 First unplug the power cord from the failed power supply module 2 To remove the failed power module push the release tab on the back of the power supply to the sid...

Страница 41: ...with the power supply 24 pin Primary ATX Power JPW1 8 pin Processor Power JPV1 4 pin GPU Power JPH1 Main ATX Power Connector The 24 pin power supply connector JPW1 meets the ATX SSI EPS 12V specifica...

Страница 42: ...Definition 1 4 Ground 5 8 12V Required Connection Processor Power Connector JPV1 is an 8 pin 12V DC power input for the CPU that must be connected to the power supply Refer to the table below for pin...

Страница 43: ...TPM http www supermicro com manuals other TPM pdf SGPIO Headers There is one Serial Link General Purpose Input Output S SGPIO1 header located on the motherboard SGPIO headers are used to communicate...

Страница 44: ...ral cards Connect the I2 C cable to this connector Power SMB I2 C Header The Power System Management Bus I2 C header at JPI2 C1 monitors the power supply fan and system temperatures Refer to the table...

Страница 45: ...or A Unit Identifier UID switch and an LED Indicator are located on the motherboard The UID switch is located at JUIDB1 which is next to the VGA port on the back panel The UID LED UID_LE1 is located n...

Страница 46: ...erformance capability in a PCI Express 3 0 x4 interface for native PCI E SSD support SATA Ports The X11SPM F has twelve SATA 3 0 ports supported by the Intel C621 and C622 chipset The AHCI controller...

Страница 47: ...ontrol panel buttons and LED indicators Reset Button Pin Definitions JF1 Pins Definition 3 Reset 4 Ground Power Button Pin Definitions JF1 Pins Definition 1 Signal 2 Ground Power Button The Power Butt...

Страница 48: ...JF1 Refer to the table below for pin definitions Power Fail LED Pin Definitions JF1 Pin Definition 5 3 3V 6 PWR Supply Fail NIC1 NIC2 LAN1 LAN2 The NIC Network Interface Controller LED connection for...

Страница 49: ...er to the table below for pin definitions Power LED Pin Definitions JF1 Pins Definition 15 3 3V 16 PWR LED NMI Button The non maskable interrupt NMI button header is located on pins 19 and 20 of JF1 R...

Страница 50: ...GA display Serial Ports There is one COM port COM1 on the I O back panel and one COM header COM2 on the motherboard LAN Ports Two LAN ports LAN1 LAN2 are located on the I O back panel There is also a...

Страница 51: ...luded Back Panel USB 0 1 2 0 Pin Definitions Pin Definition Pin Definition 1 5V 5 5V 2 USB_N 6 USB_N 3 USB_P 7 USB_P 4 Ground 8 Ground Front Panel USB 8 9 3 0 Pin Definitions Pin Definition Pin Defini...

Страница 52: ...ID switch the UID LED will be turned on Press the UID switch again to turn off the LED indicator The UID Indicator provides easy identification of a system unit that may be in need of service Note UID...

Страница 53: ...Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearin...

Страница 54: ...skable interrupt signal for the application that hangs Watch Dog must also be enabled in BIOS The default setting is Reset Note When Watch Dog is enabled the user needs to write a separate application...

Страница 55: ...per settings The default setting is Normal Manufacturing Mode Jumper Settings Jumper Setting Definition Pins 1 2 Normal Pins 2 3 Manufacturing Mode Power Source Select For USB Port 0 1 6 7 Jumper JPUS...

Страница 56: ...e information IPMI LAN Activity LED Link LED LAN 1 LAN 2 IPMI LAN X8ST3 F IPMI LAN LEDs Color State Definition Link left Green Solid Amber Solid 100 Mb s 1Gbps Activity right Amber Blinking Active Onb...

Страница 57: ...the system Note for older legacy OS s please use a method to slipstream the drivers 3 Select the partition on the drive in which to install Windows 4 Browse the USB folder for the proper driver files...

Страница 58: ...ear Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard here where you may download individual drivers and utilities to you...

Страница 59: ...Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server you can r...

Страница 60: ...nt Platform Management Interface IPMI IPMI is used to provide remote access monitoring and management There are several BIOS settings that are related to IPMI For general documentation and information...

Страница 61: ...h main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be configured The...

Страница 62: ...nd time Highlight System Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY...

Страница 63: ...Chapter 6 BIOS 63 CPLD Version This item displays the Complex Programmable Logic Device version Memory Information Total Memory This item displays the total size of memory available in the system...

Страница 64: ...his feature to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the norma...

Страница 65: ...Boot Install Windows 7 USB Support Enable this feature to use the USB keyboard and mouse during the Windows 7 installation since the native XHCI driver support is unavailable Use a SATA optical drive...

Страница 66: ...econds Override Throttle on Power Fail Use this feature to decrease system power by throttling CPU frequency when one power supply has failed The options are Disabled and Enabled CPU Configuration The...

Страница 67: ...L2 cache to improve CPU performance The options are Disable and Enable Adjacent Cache Prefetch Available when supported by the CPU The CPU prefetches the cache line for 64 bytes if this feature is se...

Страница 68: ...the P state request up to date on all Logical Processors In SW_ALL mode the OS Power Manager is responsible for coordinating the P state and must initiate the transition on all Logical Processors In...

Страница 69: ...ill significantly reduce the CPU s power consumption by reducing it s clock cycle and voltage during a Halt state The options are Disable and Enable Package C State Control Package C State This featur...

Страница 70: ...Enable for the QPI to enter the L0p state for power saving The options are Dis able Enable and Auto Link L1 Enable Select Enable for the QPI to enter the L1 state for power saving The options are Dis...

Страница 71: ...e Auto Disable and Enable tCCD_L Relaxation Select Enable to get TCDD settings from SPD Serial Presence Detect and implement into memory RC code to improve system reliability Select Disable for TCCD t...

Страница 72: ...ition is corrected on all cases The x8 condition is corrected only if the system is in Lockstep Mode The options are Disable and Enable ADDDC Sparing Adaptive Double Device Data Correction ADDDC Spari...

Страница 73: ...igures the PCI E port Bifuraction setting for a PCI E port specified by the user The options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 and Auto CPU1 SLOT4 PCI E 3 0 X16 CPU1 SLOT6 PCI E 3 0 X16 CPU1 SLOT7 P...

Страница 74: ...chnology for Direct I O VT d support by reporting the I O device assignments to the VMM Virtual Machine Monitor through the DMAR ACPI tables This feature offers fully protected I O resource sharing ac...

Страница 75: ...ll be dislayed CPU SLOT4 PCI E 3 0 X16 VMD Available when the device is detected by the system Select Enable to use the Intel Volume Management Device Technology for this spe cific root port The optio...

Страница 76: ...ug Capable Available when the device is detected by the system Use this feature to enable hot plug support for PCIe root ports 3A 3D The options are Disable and Enable PCI E Completion Timeout Disable...

Страница 77: ...and Enable Configure SATA as Select AHCI to configure a SATA drive specified by the user as an AHCI drive Select RAID to configure a SATA drive specified by the user as a RAID drive The options are A...

Страница 78: ...nd Enable Port 0 Port 7 Spin Up Device On an edge detect from 0 to 1 set this item to allow the PCH to initialize the device The options are Disable and Enable Port 0 Port 7 SATA Device Type Use this...

Страница 79: ...sSATA RAID Option ROM UEFI Driver Select UEFI to load the EFI driver for system boot Select Legacy to load a legacy driver for system boot The options are Disable EFI and Legacy sSATA Port 0 Port 3 Th...

Страница 80: ...ptions are 1G 4G 16G 64G 256G and 1024B PCI PERR SERR Support Select Enabled to allow a PCI device to generate a PERR SERR number for a PCI Bus Signal Error Event The options are Disabled and Enabled...

Страница 81: ...ed Legacy and EFI M 2 PCI E 3 0 X4 OPROM Use this feature to select which firmware type to be loaded for the add on card in this slot The options are Disabled Legacy and EFI Onboard LAN Device Select...

Страница 82: ...edia will be checked Press or on your keyboard to change the value The default setting is 1 Super IO Configuration The following Super IO information will display Super IO Chip AST2500 Serial Port 1 C...

Страница 83: ...t 2 only Select SOL to use COM Port 2 as a Serial Over LAN SOL port for console redirection The options are SOL and COM Serial Port Console Redirection COM1 Console Redirection Select Enabled to enabl...

Страница 84: ...sent along with the data bits Select Space to add a Space as a parity bit to be sent with your data bits The options are None Even Odd Mark and Space COM1 Stop Bits A stop bit indicates the end of a...

Страница 85: ...to Enabled the following items will become available for configuration SOL COM2 Console Redirection Settings Use this feature to specify how the host computer will exchange data with the client compu...

Страница 86: ...ole Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full Send a Start signal to start sending data when the receiving bu...

Страница 87: ...ature allows the user to specify how the host computer will exchange data with the client computer which is the remote computer used by the user Out of Band Mgmt Port The feature selects a serial port...

Страница 88: ...itoring The options are Disabled and Enabled High Precision Event Timer Select Enabled to activate the High Precision Event Timer HPET that produces periodic interrupts at a much higher frequency than...

Страница 89: ...t Once the name of the iSCSI Initiator is entered into the system configure the proper settings for the following items Add an Attempt Delete Attempts Change Attempt Order Intel R Virtual RAID on CPU...

Страница 90: ...led Erasing Settings Erase Event Log If No is selected data stored in the event log will not be erased Select Yes Next Reset data in the event log will be erased upon next system reboot Select Yes Eve...

Страница 91: ...incremented This is a numeric value The default value is 1 METW The Multiple Event Time Window METW defines the number of minutes that must pass between duplicate log events before MECI is incremente...

Страница 92: ...e IPMI firmware installed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Enabled and Disabled Erasing S...

Страница 93: ...t the next system boot The options are No and Yes If the item above is set to Yes the following item will become available for configuration Configuration Address Source This feature allows the user t...

Страница 94: ...rt Use this feature to enable IPV6 support The options are Enabled and Disabled Configuration Address Source This feature allows the user to select the source of the IP address for this computer If St...

Страница 95: ...or change an existing User password Password Check Select Setup for the system to check for a password at Setup Select Always for the system to check for a password at bootup or upon entering the BIO...

Страница 96: ...cure Boot keys set by the manufacturer The op tions are Disabled and Enabled Enroll All Factory Default Keys Select Yes to install all default secure keys set by the manufacturer The options are Yes a...

Страница 97: ...the manufacturer s defaults to the existing DB Select No to load the DB from a file The options are Yes and No Forbidden Signatures Set New Select Yes to load the DBX from the manufacturer s defaults...

Страница 98: ...48 bin d EFI SERT SHA256 bin 2 EFI Time Based Authenticated Variable When prompted select Yes to load Factory Defaults or No to load from a file Set New Select Yes to load the DBR from the manufacture...

Страница 99: ...order has failed The options are Disabled and Enabled Fixed Boot Order Priorities This option prioritizes the order of bootable devices that the system boots from Press Enter on each entry from top to...

Страница 100: ...15 Dual Boot Option 16 Dual Boot Option 17 Delete Boot Option This feature allows the user to select a boot device to delete from the boot priority list Delete Boot Option Use this item to remove an...

Страница 101: ...ot option Path for Boot Option Use this item to enter the path for the new boot option in the format fsx path filename efi Boot Option File Path Use this item to specify the file path for the new boot...

Страница 102: ...and press Enter Save Changes and Reset After completing the system configuration changes select this option to save the changes you have made This will not reset reboot the system Save Changes When yo...

Страница 103: ...User Defaults from the Save Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults...

Страница 104: ...nue the boot up procedure If a fatal error occurs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps Th...

Страница 105: ...m support manuals AMI BIOS POST Codes User s Guide When BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot process a diagnostic...

Страница 106: ...for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis The...

Страница 107: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...

Страница 108: ...en dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan h...

Страница 109: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...

Страница 110: ...es del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l insta...

Страница 111: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...

Страница 112: ...bels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment War...

Страница 113: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...

Страница 114: ...a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s...

Страница 115: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...

Страница 116: ...aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All co...

Страница 117: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...

Страница 118: ...vertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques ci...

Страница 119: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...

Страница 120: ...le elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accordi...

Страница 121: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...

Страница 122: ...stornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient to...

Страница 123: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSE Supermicro Supermicro UL CSA UL CSA Supermicro U...

Страница 124: ...le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto ut...

Страница 125: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...

Страница 126: ...er Drive Bays Supports up to four 4 hot swap 3 5 SATA hard drives PCI Expansion Slots One PCI E 3 0 x16 slot Motherboard X11SPM F Micro ATX form factor L x W 9 6 x 9 6 244 mm x 244 mm Chassis SC813MFT...

Страница 127: ...N 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe Perchlorate Warning California Best Management Practices Re...

Страница 128: ...main BIOS image The boot block contains critical BIOS codes including memory detection and recovery codes for the user to flash a new BIOS image if the original main BIOS image is corrupted When the s...

Страница 129: ...ry using a USB attached device follow the instructions below 1 Using a different machine copy the Super ROM binary image file into the disc Root directory of a USB device or a writable CD DVD Note If...

Страница 130: ...f you want to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 5 When the screen as shown above displays use the arrow keys to select the item Proceed wi...

Страница 131: ...r the BIOS setup utility From the top of the tool bar click on Boot and press Enter to enter the submenu From the submenu list select Boot Option 1 as shown below Then boot Option 1 to UEFI AP UEFI Bu...

Страница 132: ...terrupt this process until the BIOS flashing is complete 10 The screen above indicates that the BIOS update process is completed When you see the screen above unplug the AC power cable from the power...

Отзывы: