5.4 IPMI

The X11SCW-F supports the Intelligent Platform Management Interface (IPMI). IPMI is used 
to provide remote access, monitoring and management. There are several BIOS settings 
that are related to IPMI.
For general documentation and information on IPMI, please visit our website at: 

http://www.supermicro.com/products/nfo/IPMI.cfm.

Содержание SuperServer 5019C-WR

Страница 1: ...USER S MANUAL Revision 1 0 SuperServer 5019C WR...

Страница 2: ...commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful in...

Страница 3: ...ivers utilities and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities https www supermicro com wftp driver Product safe...

Страница 4: ...k Precautions 17 Server Precautions 18 Rack Mounting Considerations 18 Ambient Operating Temperature 18 Airflow 18 Mechanical Loading 18 Circuit Overloading 19 Reliable Ground 19 2 3 Installing the Ra...

Страница 5: ...Drive Carrier Indicators 34 DVD ROM Drive Installation 36 System Cooling 36 Installing Fans 36 Power Supply 38 Power Supply Failure 38 Chapter 4 Motherboard Connections 4 1 Power Connections 40 4 2 H...

Страница 6: ...2 Main Setup 61 6 3 Advanced Setup Configurations 63 6 4 Event Logs 86 6 5 IPMI 88 6 6 Security 91 6 7 Boot 95 6 8 Save Exit 99 Appendix A BIOS Error Codes Appendix B Standardized Warning Statements f...

Страница 7: ...r Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical S...

Страница 8: ...le a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the server It should be situated in a clean dust free area that is well ventilated Av...

Страница 9: ...of unbuffered UDIMM DDR4 288 pin ECC memory with speeds up to 2666MHz in four memory slots Chipset Intel C246 chipset Expansion Slots One Proprietary WIO L slot JSXB1A JSXB1B JSXB1C with use of RSC W...

Страница 10: ...on The reset button is used to reboot the system 8 Power Button The main power button is used to apply or remove power from the power supply to the server Turning off system power with this button rem...

Страница 11: ...nt Chassis Features Item Feature Description 1 Hard Drive Carrier Carrier for hot swap hard drive 2 Slim FDD Bay USB COM Port Tray Slim Fixed Disk Drive USB COM port tray Optional 3 Slim DVD ROM Drive...

Страница 12: ...PWS 504P 1R 2 I O Back Panel Rear I O ports see Section 4 3 3 Expansion Card Slot Slot for three expansion cards requires pre installed riser cards 4 Rack Ear Brackets Secures server chassis to the r...

Страница 13: ...SATA4 I SATA5 LEDM1 LEDEC2 LEDEC1 LE1 LEDPWR JPME2 JPG1 JPL2 JWD1 JPL1 VGA Intel i210 CPU 22110 2280 2260 22110 2280 2260 M 2 P_2 M 2 H_1 USB4 5 USB9 10 3 1 DIMMB2 DIMMB1 DIMMA2 DIMMA1 X PWR NMI LED...

Страница 14: ...en BMC Normal LEDPWR Onboard Power LED Solid Green Power On Connector Description BT1 Onboard Battery COM1 COM2 COM Port COM Header FAN1 FAN6 CPU System Fan Headers IPMI_LAN Dedicated IPMI LAN Port I...

Страница 15: ...mory JSXB1A JSXB1B JSXB1C SMC Proprietary WIO_L Left Add On Card Slot JSXB2 SMC Proprietary WIO_R Right Add On Card Slot SP1 Onboard Buzzer SRW1 4 SRW8 SRW9 M 2 Mounting Holes JUIDB1 Unit Identifier U...

Страница 16: ...2 USB2 0 1 2 3 4 PCH H 6 0 Gb S USB 2 0 eSPI SATA USB2 RTL8211FD CG RJ45 SPI Temp Sensor TPM HEADER BIOS SPI AST2500 BMC 9 10 11 12 6 COM1 Connector COM2 Header VGA Header BMC Boot Flash DDR4 6 PHASE...

Страница 17: ...ease read this section in its entirety before you begin the installation Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where hea...

Страница 18: ...r from power surges and voltage spikes and to keep your system operating in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always kee...

Страница 19: ...ion should be given to power supply connections other than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit in...

Страница 20: ...o rack rail assemblies in the rack mounting kit Each assembly consists of two sections an inner fixed chassis rail that secures directly to the server chassis and an outer fixed rack rail that secures...

Страница 21: ...place when installed and pushed fully into the rack which is its normal position Secondly these tabs also lock the server in place when fully extended from the rack This prevents the server from comin...

Страница 22: ...to both the chassis and the rack The next step is to install the server into the rack 1 Line up the rear of the chassis rails with the front of the rack rails 2 Slide the chassis rails into the rack r...

Страница 23: ...r total 1 First determine how far the server will extend out from the front of the rack The chassis should be positioned so that the weight is balanced between front and back 2 Attach the two front br...

Страница 24: ...ds from the power strip or outlet If your system has more than one power supply remove the AC power cords from all power supply modules 3 Disconnect the power cord s from the power supply modules 3 2...

Страница 25: ...nk only When receiving a motherboard without a processor pre installed make sure that the plastic CPU socket cap is in place and none of the socket pins are bent otherwise contact your retailer immedi...

Страница 26: ...he Processor Installation 4 Once aligned carefully place the processor into the socket Do not drop the processor on the socket move or rub the processor against the socket or against any socket pins w...

Страница 27: ...required amount has already been applied 1 Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the heatsink retention mechanism 2 Screw in two diagonal screw...

Страница 28: ...ons below to prevent damage to the CPU or the CPU socket 1 Unscrew and remove the heatsink screws from the motherboard in the sequence as show in the figure above 2 Hold and gently pivot the heatsink...

Страница 29: ...uence 1 DIMMB2 2 DIMMB2 DIMMA2 3 Unbalanced Not Recommended DIMMB2 DIMMA2 DIMMB1 4 DIMMB2 DIMMA2 DIMMB1 DIMMA1 DIMM Type Ranks Per DIMM and Data Width DIMM Capacity GB Speed MT s Voltage V Slot Per Ch...

Страница 30: ...3 0 DIMMA2 DIMMB1 DIMMA1 DIMMB2 Release Tabs Notches Press both ends straight down into the memory slot DIMM Installation 1 Insert the desired number of DIMMs into the memory slots based on the recom...

Страница 31: ...releasing the locking tab 3 Insert the expansion add on card into the riser card 4 Secure the card with the locking tab RSC W 68 Jumper Settings J3 Jumper Setting Definition Pins 1 2 Configures riser...

Страница 32: ...ing the Battery Begin by removing power from the system as described in section 3 1 1 Push aside the small clamp that covers the edge of the battery When the battery is released lift it out of the hol...

Страница 33: ...ng It is recommended that you keep a maintenance log to list filter cleaning replacement dates since its condition affects the airflow throughout the whole system Hard Drives Your server may or may no...

Страница 34: ...o s web site for additional information http www supermicro com support manuals Hard Drive Carrier Indicators Each hard drive carrier has two LED indicators an activity indicator and a status indicato...

Страница 35: ...ion Note Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers For information on recommended HDDs visit the Supermicro website Figure 3 10 Removing a Drive Carri...

Страница 36: ...g action generates exceptional airflow and is effective in dampening vibration levels The chassis provides two additional open fan housings where an additional system fan may be added for optimal cool...

Страница 37: ...the 5019C WR 5 Place the new fan into the vacant space in the housing while making sure the arrows on the top of the fan indicating air direction point in the same direction as the arrows on the othe...

Страница 38: ...cludes a redundant power supply which allows the server to continue running when one power supply has been removed Replacement units can be ordered directly from Supermicro Replacing the Power Supply...

Страница 39: ...Component Installation Figure 3 12 Removing Replacing a Power Supply Release Tab Note The figures above is intended to show the power supply locations only The chassis and serverboard may differ from...

Страница 40: ...ring is included with the power supply 24 pin Primary ATX Power JPWR1 8 pin Processor Power JPWR2 Main ATX Power Connector The primary power connector JPWR1 meets the ATX SSI EPS 12V pin specification...

Страница 41: ...monitors the power supply fan and system temperatures Connect the appropriate cable here to utilize SMB on your system Power SMB Header Pin Definitions Pin Definition 1 Clock 2 Data 3 PMBUS_Alert 4 G...

Страница 42: ...link for more information on the TPM http www supermicro com manuals other TPM pdf Standby Power The Standby Power header is located at JSTBY1 on the motherboard You must have a card with a Standby P...

Страница 43: ...3 0 Ports 2 3 I SGPIO2 I SATA 3 0 Ports 4 7 4 pin BMC External I2 C Header A System Management Bus header for IPMI 2 0 is located at JIPMB1 Connect the appropriate cable here to use the IPMB I2 C con...

Страница 44: ...ault pins 6 7 are closed with a cap to enable the onboard buzzer at SP1 To use an extra speaker instead connect the speaker connector to pins 4 7 Refer to the tables below for pin definitions PWR LED...

Страница 45: ...efficiency The hybrid M 2 H_1 slot supports PCI E 3 0 x4 32 Gb s SSD cards in a 2260 2280 2210 form factor or SATA 3 0 while the M 2 P_1 slot only supports PCI E 3 0 x4 Unit Identifier Switch UID LED...

Страница 46: ...connectors are designed specifically for use with Supermicro chassis See the figure below for the descriptions of the front control panel buttons and LED indicators Power Button Pin Definitions JF1 P...

Страница 47: ...ins 5 and 6 of JF1 Refer to the table below for pin definitions Power Fail LED Pin Definitions JF1 Pin Definition 5 3 3V 6 PWR Supply Fail Ovearheat Fan Fail and UID LED Connect an LED cable to pins 7...

Страница 48: ...on is located on pins 13 and 14 of JF1 Attach a cable to pin 14 to show hard drive activity status Attach a cable to pin 13 to use the UID switch Refer to the table below for pin definitions HDD LED U...

Страница 49: ...ription 1 COM1 Port 6 USB6 USB 3 1 Gen 2 2 Dedicated IPMI LAN 7 LAN1 3 USB1 8 LAN2 4 USB0 9 VGA Port 5 USB7 USB 3 1 Gen 2 10 UID Switch 9 8 7 6 1 5 4 3 2 10 VGA Port The onboard VGA port is located ne...

Страница 50: ...Definitions Pin Definition Pin Definition 1 5V 2 5V 3 USB_N 4 USB_N 5 USB_P 6 USB_P 7 GND 8 GND 9 Key 10 NC Type A USB 8 USB 3 1 Gen 1 Pin Definitions Pin Definition Pin Definition 1 VBUS 5 SSRX 2 USB...

Страница 51: ...D information LAN Ports Pin Definition Pin Definition Pin Definition 1 TRCT2 11 TD4 2 TD2 12 TRCT4 3 TD2 13 Act LED Green 4 TD3 14 P3V3 5 TD3 15 Link 1000 LED Amber 6 TRCT3 16 P3V3 7 TRCT1 17 Link 100...

Страница 52: ...Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearin...

Страница 53: ...security and force the system to operate in manufacturing mode which will allow the user to flash the system firmware from a host server for system setting modifications Refer to the table below for...

Страница 54: ...ff to indicate the speed of the connection Refer to the tables below for more information LAN Activity LED Right LED State Color Status Definition Green Flashing Active LAN Link LED Left LED State LED...

Страница 55: ...n the system is on Be sure to turn off the system and unplug the power cord before removing or installing components Refer to the table below for more information Onboard Power LED Indicator LED Color...

Страница 56: ...USB port on the system Note for older legacy OS s please use a method to slipstream the drivers 3 Select the partition on the drive in which to install Windows 4 Browse the USB folder for the proper d...

Страница 57: ...1 should appear Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard here where you may download individual drivers and uti...

Страница 58: ...agement Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server y...

Страница 59: ...orm Management Interface IPMI IPMI is used to provide remote access monitoring and management There are several BIOS settings that are related to IPMI For general documentation and information on IPMI...

Страница 60: ...2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be config...

Страница 61: ...Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY format The time is enter...

Страница 62: ...62 SuperServer 5019C WR User s Manual EC Version This item displays the Embedded Controller version Memory Information Total Memory This item displays the total size of memory available in the system...

Страница 63: ...eature to reduce the time the computer takes to boot up The computer will boot with a minimal set of required devices This feature does not have an effect on BBS boot options in the Boot tab The optio...

Страница 64: ...is feature to set the power state after a power outage Select Stay Off for the system power to remain off after a power loss Select Power On for the system power to be turned on after a power loss Sel...

Страница 65: ...ide is enabled this feature sets the value for the CPU Flex Ratio This value must be between the maximum efficiency ratio and maximum non turbo ratio The default value is dependent on the CPU Hardware...

Страница 66: ...Test BIST at system reset or reboot The options are Disabled and Enabled AES Select Enabled to use the Intel Advanced Encryption Standard AES to ensure data security The options are Disabled and Enab...

Страница 67: ...feature for the CPU C1E drops the frequency and voltage of the CPU to reduce power usage when the system is idle The options are Disabled and Enabled C State Auto Demotion Use this feature to prevent...

Страница 68: ...ard memory modules The options are Auto 1067 1333 1400 1600 1800 1867 2000 2133 2200 2400 2600 and 2667 ECC Support Use this feature to enable Error Checking Correction ECC support for onboard memory...

Страница 69: ...l Use this feature to enable or disable the DMI extended synchronization The options are Enabled and Disabled DMI De Emphasis Control Use this feature to configure the De emphasis control on DMI The o...

Страница 70: ...Disabled the PCI E ASPM will be programmed before OPROM The options are Disabled and Enabled VT d Select Enable to use Intel Virtualization Technology for Direct I O VT d support by reporting the I O...

Страница 71: ...ntrols the Active State Power Management ASPM setting The op tions are Disabled L0s L1 L0sL1 and Auto M 2 H L1 Substates Use this feature to configure the PCI Express L1 Substates The options are Dis...

Страница 72: ...llow the BIOS to automatically assign the base I O and IRQ address The options for Serial Port 1 are Auto IO 3F8h IRQ 4 IO 2F8h IRQ 4 IO 3E8h IRQ 4 and IO 2E8h IRQ 4 Serial Port 2 Configuration This s...

Страница 73: ...coding to map Unicode characters into one or more bytes The options are VT100 VT100 VT UTF8 and ANSI COM1 Bits Per Second Use this feature to set the transmission speed for a serial port used in Conso...

Страница 74: ...ution 100x31 Select Enabled for extended terminal resolution support The options are Disabled and Enabled COM1 Legacy OS Redirection Resolution Use this feature to select the number of rows and column...

Страница 75: ...d 8 Bits COM2 SOL Parity A parity bit can be sent along with regular data bits to detect data transmission errors Select Even if the parity bit is set to 0 and the number of 1 s in data bits is even S...

Страница 76: ...legacy console redirection after BIOS POST When set to BootLoader legacy console redirection is disabled before booting the OS When set to Always Enable legacy console redirection remains enabled whe...

Страница 77: ...get terminal emulation type for Console Redirection Select VT100 to use the ASCII character set Select VT100 to add color and function key support Select ANSI to use the extended ASCII character set S...

Страница 78: ...s set to Enabled the SATA AHCI controller manages the power usage of the SATA link The controller will put the link in a low power mode during extended periods of I O inactivity and will return the li...

Страница 79: ...dows OS environment to reduce system crashes and to enhance system recovery and health monitoring The options are Disabled and Enabled High Precision Event Timer Select Enabled to activate the High Pr...

Страница 80: ...ating systems that do not support eXtensible Host Controller Interface XHCI hand off When this feature is enabled XHCI ownership change will be claimed by the XHCI driver The settings are Enabled and...

Страница 81: ...AMI Native Support is offered by the BIOS with a generic method PCIe PCI PnP Configuration RSC W 68 SLOT1 PCI E 3 0 x16 OPROM RSC W 68 SLOT2 PCI E 3 0 x8 OPROM Use this feature to select which firmwar...

Страница 82: ...enable IPv6 PXE boot support The options are Disabled and Enabled Ipv6 HTTP Support Select Enabled to enable IPv6 HTTP boot support The options are Disabled and Enabled IPSEC Certificate Internet Prot...

Страница 83: ...e SHA256 Platform Configuration Register PCR bank for the installed TPM device The options are Disabled and Enabled Pending Operation Use this feature to schedule a TPM related operation to be perform...

Страница 84: ...to enable the Supermicro TPM Provision support The options are Disabled and Enabled TXT Support Intel Trusted Execution Technology TXT helps protect against software based attacks and ensures protecti...

Страница 85: ...d an Attempt Delete Attempts Change Attempt Order TLS Authentication Configuration This submenu allows the user to configure Transport Layer Security TLS settings Server CA Configuration Enroll Certif...

Страница 86: ...led Erasing Settings Erase Event Log If No is selected data stored in the event log will not be erased Select Yes Next reset data in the event log will be erased upon next system reboot Select Yes Eve...

Страница 87: ...incremented This is a numeric value The default value is 1 METW The Multiple Event Time Window METW defines the number of minutes that must pass between duplicate log events before MECI is incremente...

Страница 88: ...IPMI firmware installed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Disabled and Enabled Erasing Se...

Страница 89: ...ting The default setting is Failover IPMI Network Link Status This feature displays the IPMI Network Link status The default setting is Shared LAN Configuration Address Source This feature allows the...

Страница 90: ...his feature displays the IPV6 Address status The default setting is Disabled IPV6 Support Use this feature to enable IPV6 support The options are Enabled and Disabled If the feature above is set to En...

Страница 91: ...Setup utility The options are Setup and Always Administrator Password Press Enter to create a new or change an existing Administrator password Secure Boot This section displays the contents of the fo...

Страница 92: ...tions are Yes and No Export Secure Boot variables Use this feature to copy the NVRAM contents of the secure boot variables to a file Enroll EFI Image This feature allows the image to run in Secure Boo...

Страница 93: ...the manufacturer s defaults to the existing DB Select No to load the DB from a file The options are Yes and No Forbidden Signatures Update Select Yes to load the DBX from the manufacturer s defaults S...

Страница 94: ...48 bin d EFI SERT SHA256 bin 2 EFI Time Based Authenticated Variable When prompted select Yes to load Factory Defaults or No to load from a file Update Select Yes to load the DBR from the manufacturer...

Страница 95: ...Select Use this feature to select the type of device that the system is going to boot from The options are Legacy UEFI and Dual Fixed Boot Order Priorities This feature prioritizes the order of boota...

Страница 96: ...s the user to select an EFI boot option to delete from the boot order Delete Boot Option Use this feature to remove an EFI boot option from the boot priority list Delete Driver Option This feature all...

Страница 97: ...ecify the name for the new driver option Path for Boot Option Use this feature to enter the path for the new driver option in the format fsx path filename efi Driver Option File Path Use this feature...

Страница 98: ...er s Manual UEFI Hard Disk Drive BBS Priorities This feature sets the system boot order of detected devices Boot Option 1 Hard Disk Drive BBS Priorities This feature sets the system boot order of dete...

Страница 99: ...ter Save Changes and Reset After completing the system configuration changes select this option to save the changes you have made This will not reset reboot the system Save Changes When you have compl...

Страница 100: ...ve as User Defaults from the Save Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Def...

Страница 101: ...sponding error beep codes that may be encountered by users BIOS Beep POST Codes Beep Code Error Message Description 1 beep Refresh Circuits have been reset Ready to power up 5 short 1 long Memory erro...

Страница 102: ...or assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis Thes...

Страница 103: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...

Страница 104: ...n dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan he...

Страница 105: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...

Страница 106: ...s del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l instal...

Страница 107: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...

Страница 108: ...els aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Warn...

Страница 109: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...

Страница 110: ...una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s u...

Страница 111: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...

Страница 112: ...anbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All con...

Страница 113: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...

Страница 114: ...ertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques cir...

Страница 115: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...

Страница 116: ...e elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accordin...

Страница 117: ...Swap Fan Warning Warning The fans might still be turning when you remove the fan assembly from the chassis Keep fingers screwdrivers and other objects away from the openings in the fan assembly s hous...

Страница 118: ...s los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez le bloc ventilateur d...

Страница 119: ...tadores de CA La utilizaci n de otros cables y adaptadores podr a ocasionar un mal funcionamiento o un incendio Aparatos El ctricos y la Ley de Seguridad del Material proh be el uso de UL o CSA cables...

Страница 120: ...appareils lectriques que les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA UL CSA Supermicro UL CSA AC Electrical Appliance and Material Safety Law UL CSA UL CSA Waarschuwing Bij het...

Страница 121: ...t using RSC R1UW E8R riser card One Proprietary WIO L slot using RSC W 68 riser card One M 2 slot for PCI E 3 0 x4 supports M Key 2260 2280 22110 FF and Intel Optane memory One M 2 slot for PCI E 3 0...

Страница 122: ...11 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe Other VCCI CISPR 32 and AS NZS CISPR 32 Environmental Directive 2011 65 EU and Directive 2012 19 EU Perchlor...

Отзывы: