Chapter 2: Server Installation
20
2.3 Installing the Rails
There are a variety of rack units on the market, which may require a slightly different assembly
procedure.
The following is a basic guideline for installing the system into a rack with the rack mounting
hardware provided. You should also refer to the installation instructions that came with the
specific rack you are using.
Identifying the Rails
The rack rails and the related hardware should have been included with the system. Refer to
Figure 2-1 to identify the rail sections. Note that these two rails are left/right specific
Installing the Chassis Rails
Begin the rack mounting procedure by installing the inner rails to the server chassis.
1. Position the front and rear chassis rail sections along the side of the server making sure
the screw holes line up. Note that these two rails are left/right specific.
2. Screw the front chassis rail (the long piece) securely to the side of the chassis (see
Figure 2-2). There should be two screws for each side. Repeat this procedure for the
other rail on the opposite side of the chassis.
3. Attach the two rear chassis rails to the chassis in the same manner, again keeping in
mind that the rails are left/right specific. (You will also need to attach the rail brackets
when installng into a telco rack.)
Warning:
do not pick up the server with the front handles. They are designed to pull
the system from a rack only.
Slide rail mounted equipment is not to be used as a shelf or a work space.