USER’S MANUAL
Revision 1.0
S
UpER
ERvER
5019C-L
5019C-FL
Страница 1: ...USER S MANUAL Revision 1 0 SuperServer 5019C L 5019C FL...
Страница 2: ...commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful int...
Страница 3: ...nd the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities https www supermicro com wftp Product safety info http www supermi...
Страница 4: ...nts 16 1 7 Returning Merchandise for Service 16 Chapter 2 Server Installation 2 1 Overview 17 2 2 Preparing for Setup 17 Choosing a Setup Location 17 Rack Precautions 17 Server Precautions 18 Rack Mou...
Страница 5: ...s 33 PCI Expansion Cards 35 System Fans 36 Installing the Air Shroud 38 Checking the Server Air Flow 39 Overheating 39 Power Supply 40 Chapter 4 Motherboard Connections 4 1 Power Connections 41 4 2 He...
Страница 6: ...lity 55 6 2 Main Setup 55 6 3 Advanced Settings Menu 57 6 4 Event Logs 79 6 5 IPMI 81 6 6 Security Settings 84 6 7 Boot Settings 88 6 8 Save Exit 91 Appendix A BIOS Error Codes Appendix B Standardized...
Страница 7: ...ddress Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl...
Страница 8: ...ity Power supply module PWS 203 1H 1 Fans FAN 0154L4 2 default Air Shroud MCP 310 50504 0B 1 Heatsink SNK P0049P 1 Riser Card RSC RR1U E16 1 1 2 Unpacking the System Inspect the box the system was shi...
Страница 9: ...mory slots DIMM size up to 32 GB at 1 2 V Chipset Intel C242 Expansion Slots One PCI Express 3 0 x16 slot Note depends on the number of storage drives installed Storage Drives Up to four internal driv...
Страница 10: ...utton Reboots the system 7 Power Button Applies or removes power from the power supply to the server standby power is maintained Information LED Status Description Continuously on and red An overheat...
Страница 11: ...ttons see preceding page 2 I O Ports Input Output ports see next page and Section 4 3 for details 3 PCI Slot Slot for an expansion card Figure 1 2 5019C L SC504 Chassis Front View Front Features The i...
Страница 12: ...View Chassis Rear Features Item Features Description 1 Power Supply Fixed internal module 2 I O Panel SC504 Rear I O ports see below and Section 4 3 3 PCI Slot SC504 Slot for one expansion card Figur...
Страница 13: ...ED1 JPME2 JWD1 JPL2 JPG1 JSTBY1 USB2 3 CPU SLOT1 PCI E 3 0 X16 B1 JL1 LED4 M 2 H MH5 LED2 JUIDB1 JD1 LED5 SP1 VGA JTPM1 CPU USB6 7 3 0 LAN1 2 USB8 3 0 JBT1 USB4 5 3 0 I SATA0 JSD2 I SATA1 JSD1 USB0 1...
Страница 14: ...Speaker Pins 3 4 Onboard Buzzer JF1 Front Control Panel Header JL1 Chassis Intrusion Header JLED1 3 pin Power LED Header JPW1 24 pin ATX Power Supply Connector JPW2 4 pin Power Connector JSD1 JSD2 SA...
Страница 15: ...GA1151 SVID DDR4 CHA DIMMA1 DDR4 CHB 65W 71 W 80W 95W PCIe x16 SLOT 6 DIMMB1 RJ45 GLAN2 I210 AT RJ45 GLAN1 I210 AT PCIEX4 M 2 M KEY REAR USB USB Header VGA 32MB PCH_SPI PCH CPU BMC RMII NCSI MUX LANUS...
Страница 16: ...should be prominently displayed on the outside of the shipping carton and mailed prepaid or hand carried Shipping and handling charges will be applied for all orders that must be mailed when service i...
Страница 17: ...ation Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated Leave e...
Страница 18: ...ture If installed in a closed or multi unit rack assembly the ambient operating temperature of the rack environment may be greater than the room s ambient temperature Therefore consideration should be...
Страница 19: ...n mounting or servicing this unit in a rack you must take special precautions to ensure that the system remains stable The following guidelines are provided to ensure your safety This unit should be m...
Страница 20: ...Server into a Rack 2 3 Installing the System Into a Rack This section provides information on installing the 5019C L FL system into a rack The chassis has two rack mounting ear brackets which are loca...
Страница 21: ...a Telco Rack Installing the Server into a Telco Rack If you are installing the system into a two post Telco rack follow the directions given on the previous pages for rack installation The only diffe...
Страница 22: ...ire that power first be removed from the system Please follow the procedures given in each section 3 1 Removing Power Use the following procedure to ensure that power has been removed from the system...
Страница 23: ...e screws that hold the chassis cover in place There are two screws on each side of the chassis and one screw on the back 2 Slide the cover toward the rear and lift it off the chassis Check that all ve...
Страница 24: ...acing direct pressure on the LGA lands gold contacts Improper installation or socket misalignment can cause serious damage to the processor or CPU socket which may require manufacturer repairs Refer t...
Страница 25: ...the CPU by the edges with your thumb and index finger align the triangle on the CPU with the triangle on the socket The CPU keys the semi circle cutouts may also be aligned against the socket keys as...
Страница 26: ...operly installed Load lever locked into place Note You can only install the CPU in one direction Make sure it is properly inserted into the socket before closing the load plate If it doesn t close pro...
Страница 27: ...ce the heatsink on top of the CPU so that the four mounting holes are aligned with those on the heatsink retention bracket 2 Screw in two diagonal screws i e the 1 and the 2 screws until they are just...
Страница 28: ...the heatsink back and forth to loosen it from the CPU Do not use excessive force when dislodging the heatsink 3 Once the heatsink is loose remove it from the CPU 4 Clean the surface of the CPU and the...
Страница 29: ...idth DIMM Capacity GB Speed MT s Voltage V Slot Per Channel SPC and DIMM Per Channel DPC 1 Slot Per Channel DRAM Density 1DPC 4GB 8GB 1 2V Unbuffered DDR4 ECC SR 8GB 2x 4GB DIMMs 16GB 2x 8GB DIMMs 266...
Страница 30: ...10 Intel C242 ASpeed AST2500 JPL1 FANA JLED1 JPME2 JWD1 JPL2 JPG1 JSTBY1 USB2 3 CPU SLOT1 PCI E 3 0 X16 B1 JL1 LED4 M 2 H MH5 LED2 JUIDB1 JD1 LED5 SP1 VGA JTPM1 CPU USB6 7 3 0 LAN1 2 USB8 3 0 JBT1 USB...
Страница 31: ...both edges straight down into the memory slot Notches Release Tabs 2 Align the key of the DIMM with the receptive point on the memory slot and with your thumbs on both ends of the module press it str...
Страница 32: ...cing the Battery Begin by removing power from the system as described in section 3 1 1 Push aside the small clamp that covers the edge of the battery When the battery is released lift it out of the ho...
Страница 33: ...the server as described in Section 3 1 and remove the cover 2 Install up to four 2 5 drive s into the drive bracket s and secure them to the bracket with the screws provided 3 Place the drive and bra...
Страница 34: ...e 3 6 Four 2 5 Drives In Two Double Brackets No Expansion Card Figure 3 7 One 3 5 Drives and One Low Profile Expansion Card Figure 3 8 Two 2 5 Drives and One Full Height Half Length Expansion Card Fig...
Страница 35: ...ull height half length card See also the Storage Drive section Installing PCI Expansion Cards Note When installing with 2 5 storage drives install the drives first 1 Remove power as described in secti...
Страница 36: ...top cover must be installed during normal operation to insure proper airflow Replacing System Fans 1 Determine which fan has failed using IPMI or if necessary open the chassis while the system is runn...
Страница 37: ...37 Chapter 3 Maintenance and Component Installation Figure 3 11 SC504 203B Installing Fans showing optional third fan Figure 3 12 SC505 203B Installing Fans showing optional third fan...
Страница 38: ...ir shrouds concentrate airflow to maximize fan efficiency It does not require screws to install Installing the Air Shroud Position the air shroud in the chassis as illustrated below If necessary move...
Страница 39: ...cess cabling out of the airflow path or use shorter cables The control panel LEDs display system heat status See Control Panel in Chapter 1 for details Overheating There are several possible responses...
Страница 40: ...dule 1 Power down the system and unplug the AC cord from the module 2 Remove the power cables to internal components 3 Remove the mounting screws two on the chassis rear and two under the chassis floo...
Страница 41: ...TX SSI EPS 12V specification An 4 pin JPW2 processor power connector must also be connected to your power supply ATX Power 24 pin Connector Pin Definitions Pin Definition Pin Definition 13 3 3V 1 3 3V...
Страница 42: ...eader The JTPM1 header is used to connect a Trusted Platform Module TPM Port 80 which is available from Supermicro TPM Port 80 is a security device which supports encryption and authentication in hard...
Страница 43: ...header is used to communicate with the enclosure management chip on the back panel SGPIO Header Pin Definitions Pin Definition Pin Definition 1 NC 2 NC 3 GND 4 DATA Out 5 Load 6 GND 7 Clock 8 NC NC No...
Страница 44: ...r connector to pins 1 4 Speaker Onboard Buzzer Header Pin Definitions Pin Signal 1 P5V 2 Key 3 R_SPKPIN_N 4 R_SPKPIN SATA Ports The X11SCL iF has four SATA 3 0 ports I SATA0 I SATA3 supported by the I...
Страница 45: ...ked on the motherboard The other end connects to the control panel PCB board Power Button Pin Definitions JF1 Pins Definition 1 Signal 2 Ground Power Button The Power Button connection is located on p...
Страница 46: ...Refer to the table below for pin definitions HDD LED Pin Definitions JF1 Pins Definition 13 3 3V Stdby 14 HDD Active Overheat OH Fan Fail LED Connect an LED cable to pins 7 and 8 of the Front Control...
Страница 47: ...er to the table below for pin definitions Power LED Pin Definitions JF1 Pins Definition 15 3 3V 16 PWR LED NMI Button The non maskable interrupt NMI button header is located on pins 19 and 20 of JF1 R...
Страница 48: ...ID LED indicator illuminates Press the UID switch again to turn off the UID LED The UID indicator provides easy identification of a system unit that might be in need of service Note UID can also be tr...
Страница 49: ...oved Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which also clears any passwords Instead of pins this jumper consists of contact pads to prevent accidentally cleari...
Страница 50: ...ns 1 2 Normal Pins 2 3 Manufacturing Mode Watchdog Timer Watchdog JWD1 is a system monitor that can reboot the system when a software application hangs Close pins 1 2 to reset the system if an applica...
Страница 51: ...is located near the UID switch on the I O panel If activated this LED provides easy identification of a unit that may need service Onboard Power LED The Onboard Power LED is located at LED3 on the mot...
Страница 52: ...cy OS s please use a method to slipstream the drivers 3 Select the partition on the drive in which to install Windows 4 Browse the USB folder for the proper driver files 5 Choose the RAID driver indic...
Страница 53: ...r Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard here where you may download individual drivers and utilities to your...
Страница 54: ...ctor 5 Management Server SSM Server you can remotely control power on off and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI SuperDoctor 5 Management Server monitors HTTP FTP...
Страница 55: ...ected it is highlighted in white Settings printed in Bold are the default values In the left frame a indicates a submenu Highlighting such an item and pressing the Enter key opens the list of settings...
Страница 56: ...Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30...
Страница 57: ...anufacture default setting Boot Feature Fast Boot Enable this feature to reduce the time the computer takes to boot up The computer will boot with a minimal set of required devices This feature does n...
Страница 58: ...are Disabled and Enabled AC Loss Policy Depend On Use this feature to set the power state after a power outage Select Stay Off for the system power to remain off after a power loss Select Power On for...
Страница 59: ...ide is enabled this feature sets the value for the CPU Flex Ratio This value must be between the maximum efficiency ratio and maximum non turbo ratio The default value is dependent on the CPU Hardware...
Страница 60: ...AES Select Enabled to use the Intel Advanced Encryption Standard AES to ensure data security The options are Disabled and Enabled Boot Performance Mode This feature allows the user to select the perf...
Страница 61: ...bled and Enabled C State Auto Demotion Use this feature to prevent unnecessary excursions into C States to improve latency The options are Disabled C1 C3 and C1 and C3 C State Un Demotion This feature...
Страница 62: ...les The options are Disabled and Enabled Max TOLUD This feature sets the maximum TOLUD value which specifies the Top of Low Usable DRAM memory space to be used by internal graphic devices GTT Stolen M...
Страница 63: ...e this feature to enable or disable the PCI Express Graphics PEG device in the port specified by the user The options are Disabled Enabled and Auto Max Link Speed Use this feature to configure the lin...
Страница 64: ...ers fully protected I O resource sharing across Intel platforms providing greater reliability security and availability in networking and data sharing The options are Disabled and Enabled SW Guard Ext...
Страница 65: ...n1 Gen2 and Gen3 Port 61h Bit 4 Emulation Select Enabled to enable the emulation of Port 61h bit 4 toggling in System Management Mode SMM The options are Disabled and Enabled PCIE PLL SSC Use this fea...
Страница 66: ...serial port specified by the user Select Auto to allow the BIOS to automatically assign the base I O and IRQ address The options for SOL are Auto IO 3F8h IRQ 3 IO 2F8h IRQ 3 IO 3E8h IRQ 3 and IO 2E8h...
Страница 67: ...smission Select Mark to add a mark as a parity bit to be sent along with the data bits Select Space to add a Space as a parity bit to be sent with your data bits The options are None Even Odd Mark and...
Страница 68: ...eature above is set to Enabled the following settings will become available for configuration SOL Console Redirection Settings Use this feature to specify how the host computer will exchange data with...
Страница 69: ...data when the receiving buffer is empty The options are None and Hardware RTS CTS VT UTF8 Combo Key Support Select Enabled to enable VT UTF8 Combination Key support for ANSI VT100 terminals The option...
Страница 70: ...EMS Console Redirection Select Enabled to enable console redirection support for a serial port specified by the user The options are Disabled and Enabled If the feature above is set to Enabled the fo...
Страница 71: ...hip and displays the following features SATA Controller s This feature enables or disables the onboard SATA controller supported by the Intel PCH chip The options are Enabled and Disabled If the featu...
Страница 72: ...0 Port 3 SATA Device Type Use this feature to specify if the SATA port specified by the user should be connected to a Solid State drive or a Hard Disk Drive The options are Hard Disk Drive and Solid...
Страница 73: ...ntrol the ASPM The options are Auto Enabled and Disabled USB Configuration The following USB items will be displayed USB Module Version USB Controllers USB Devices Legacy USB Support Available when US...
Страница 74: ...and EFI NVMe Firmware Source Use this feature to select the NVMe firmware to support booting The options are Vendor Defined Firmware and AMI Native Support The default option Vendor Defined Firmware i...
Страница 75: ...support The options are Disabled and Enabled Ipv6 PXE Support Select Enabled to enable IPv6 PXE boot support The options are Disabled and Enabled Ipv6 HTTP Support Select Enabled to enable IPv6 HTTP...
Страница 76: ...R bank for the installed TPM device The options are Disabled and Enabled Pending Operation Use this feature to schedule a TPM related operation to be performed by a security device for system data int...
Страница 77: ...created on the system Use this feature to enable or disable TXT Suppport The options are Disabled and Enabled HTTP Boot Configuration Http Boot One Time After creating and saving a HTTP boot option e...
Страница 78: ...nfiguration Enroll Certification Enroll Certification Using File Use this feature to enroll certification from a file Certification GUID Use this feature to input the certification GUID Commit Changes...
Страница 79: ...ng Settings Erase Event Log If No is selected data stored in the event log will not be erased Select Yes Next reset data in the event log will be erased upon next system reboot Select Yes Every reset...
Страница 80: ...counter is incremented This is a numeric value The default value is 1 METW The Multiple Event Time Window METW defines the number of minutes that must pass between duplicate log events before MECI is...
Страница 81: ...Controller This item indicates the status of the IPMI firmware installed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup...
Страница 82: ...tion Configure IPV4 Support This section displays configuration features for IPV4 support IPMI LAN Selection This feature displays the IPMI LAN setting The default setting is Failover IPMI Network Lin...
Страница 83: ...splays configuration features for IPV6 support IPV6 Address Status This feature displays the IPV6 Address status The default setting is Disabled IPV6 Support Use this feature to enable IPV6 support Th...
Страница 84: ...m to check for a password at bootup or upon entering the BIOS Setup utility The options are Setup and Always Administrator Password Press Enter to create a new or change an existing Administrator pass...
Страница 85: ...No Reset to Setup Mode Select Yes to delete all Secure Boot key databases and force the system to Setup Mode The options are Yes and No Export Secure Boot variables Use this feature to copy the NVRAM...
Страница 86: ...e The options are Yes and No Append Select Yes to add the database from the manufacturer s defaults to the existing DB Select No to load the DB from a file The options are Yes and No Forbidden Signatu...
Страница 87: ...FI SERT SHA256 bin 2 EFI Time Based Authenticated Variable When prompted select Yes to load Factory Defaults or No to load from a file Update Select Yes to load the DBR from the manufacturer s default...
Страница 88: ...g is 1 Boot Mode Select Use this feature to select the type of device that the system is going to boot from The options are Legacy UEFI and Dual Fixed Boot Order Priorities This feature prioritizes th...
Страница 89: ...ove an EFI boot option from the boot priority list Delete Driver Option This feature allows the user to select an EFI driver option to delete from the drive order If any storage media is detected Add...
Страница 90: ...e to specify the file path for the new driver option Create Use this feature to set the name and the file path of the new driver option UEFI Application Boot Priorities This feature allows the user to...
Страница 91: ...and Reset After completing the system configuration changes select this option to save the changes you have made This will not reset reboot the system Save Changes When you have completed the system c...
Страница 92: ...ve as User Defaults from the Save Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Def...
Страница 93: ...orresponding beep codes encountered by users BIOS Error Beep POST Codes Beep Code Error Message Description 1 short Refresh Circuits have been reset Ready to power up 5 short 1 long Memory error No me...
Страница 94: ...r assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis These...
Страница 95: ...o considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar...
Страница 96: ...en dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan h...
Страница 97: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...
Страница 98: ...es del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l insta...
Страница 99: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...
Страница 100: ...bels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment War...
Страница 101: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...
Страница 102: ...a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s...
Страница 103: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...
Страница 104: ...aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All co...
Страница 105: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...
Страница 106: ...vertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques ci...
Страница 107: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...
Страница 108: ...le elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accordi...
Страница 109: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...
Страница 110: ...stornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient to...
Страница 111: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSE Supermicro Supermicro UL CSA UL CSA Supermicro U...
Страница 112: ...le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto ut...
Страница 113: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...
Страница 114: ...PCI Expansion Slots One PCI Express 3 0 x16 slot Note Depends on the number of storage drives Input Output Network Two 1 GbE BASE T ports one dedicated IPMI port USB Two USB 2 0 two USB 3 1 Gen 1 Vide...
Страница 115: ...1 Other VCCI CISPR 32 and AS NZS CISPR 32 Environmental Directive 2011 65 EU and Directive 2012 19 EU Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe Perchlora...
Страница 116: ...e The recovery block contains critical BIOS codes including memory detection and recovery codes for the user to flash a healthy BIOS image if the original main BIOS image is corrupted When the system...
Страница 117: ...ifferent machine copy the Super ROM binary image file into the Root directory of a USB device or a writable CD DVD Note 1 If you cannot locate the Super ROM file in your drive disk visit our website a...
Страница 118: ...if you want to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 4 When the screen as shown above displays use the arrow keys to select the item Proceed w...
Страница 119: ...to enter the BIOS Setup utility From the top of the tool bar select Boot to enter the submenu From the submenu list select Boot Option 1 as shown below Then set Boot Option 1 to UEFI AP UEFI Built in...
Страница 120: ...terrupt this process until the BIOS flashing is complete 9 The screen above indicates that the BIOS update process is complete When you see the screen above unplug the AC power cable from the power su...