5-16
S
UPER
S
ERVER 5016i-URF User's Manual
NIC1/NIC2 (LAN1/LAN2)
The NIC (Network Interface Controller)
LED connection for LAN port 1 is located
on pins 11 and 12 of JF1, and the LED
connection for LAN Port 2 is on Pins 9
and 10. NIC1 LED and NIC2 LED are
2-pin NIC LED headers. Attach NIC LED
cables to NIC1 LED and NIC2 LED to
display network activities for LAN 1 and
LAN2. Refer to the table on the right for
pin defi nitions.
LAN1/LAN2 LED
Pin Defi nitions (JF1)
Pin# Defi nition
9/11
Vcc
10/12
LAN Act
Overheat (OH)/Fan Fail/Front UID
LED
Connect an LED cable to the Front UID
and OH/Fan Fail connections on pins 7
and 8 of JF1 to display UID (Unit ID) sig-
nals or to provide advanced warnings for
chassis overheat/fan failure. Refer to the
table on the right for pin defi nitions.
OH/Fan Fail LED
Pin Defi nitions (JF1)
Pin# Defi nition
7
Vcc/Blue UID LED
8
OH/Fan Fail LED
OH/Fan Fail Indicator
Status
State Defi nition
Off
Normal
On
Overheat
Flash-
ing
Fan Fail
Reset Button
The Reset Button connection is located
on pins 3 and 4 of JF1. Attach it to a the
hardware Reset Button on the computer
case. Refer to the table on the right for
pin defi nitions.
Reset Button
Pin Defi nitions (JF1)
Pin# Defi nition
3
Reset
4
Ground
Power Fail LED
The Power Fail LED connection is located
on pins 5 and 6 of JF1. Attach an LED
cable here to indicate when there has
been a power outage. Refer to the table
on the right for pin defi nitions.
PWR Fail LED
Pin Defi nitions (JF1)
Pin# Defi nition
5
Vcc
6
Ground
Содержание SUPERSERVER 5016i-URF
Страница 1: ...SUPERSERVER 5016i URF SUPER USER S MANUAL 1 0a...
Страница 5: ...v Preface Notes...
Страница 48: ...4 20 SUPERSERVER 5016i URF User s Manual Notes...
Страница 86: ...6 10 SUPERSERVER 5016i URF User s Manual Figure 6 6 Removing Replacing the Power Supply...
Страница 110: ...7 24 SUPERSERVER 5016i URF User s Manual Notes...
Страница 112: ...A 2 SUPERSERVER 5016i URF User s Manual Notes...