USER’S MANUAL
Revision 1.0
d
SuperServer
®
2029U-TN24R4T
Страница 1: ...USER S MANUAL Revision 1 0d SuperServer 2029U TN24R4T...
Страница 2: ...commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful int...
Страница 3: ...and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities https www supermicro com wftp Product safety info http www super...
Страница 4: ...for Service 17 Chapter 2 Server Installation 2 1 Overview 18 2 2 Preparing for Setup 18 Choosing a Setup Location 18 Rack Precautions 18 Server Precautions 19 Rack Mounting Considerations 19 Ambient...
Страница 5: ...essor Heatsink Module 34 Memory 35 Memory Support 35 Memory Population Guidelines 36 Memory Population Sequence 36 DCPMM Population Table 24 Slots based on the 82xx 62xx 52xx 42xx 39 Installing Memory...
Страница 6: ...age Ports 72 Chapter 5 Software 5 1 Microsoft Windows OS Installation 73 5 2 Driver Installation 75 5 3 SuperDoctor 5 76 5 4 IPMI 77 Chapter 6 BIOS 6 1 Introduction 78 Starting BIOS Setup Utility 78 6...
Страница 7: ...permicro com Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information s...
Страница 8: ...UR6N4 i4XT P 1 Riser cards RSC U2N4 6 RSC_UMR 8 1 each Fans FAN 0158L4 4 Air Shrouds MCP 310 82921 0N MCP 310 82922 0N 1 each Heatsinks SNK P0068PS 2 Rack mount rails MCP 290 00053 0N 01 1 set 1 2 Unp...
Страница 9: ...Load Reduced DIMM LRDIMM with speeds of up to 2933 MHz support for Non Volatile DIMM NVDIMM and Intel Optane DC Persistent Memory DCPMM Chipset Intel C621 Expansion Slots Two full height 10 5 length...
Страница 10: ...r but maintains standby power 2 Reset button Reboots the system 3 Power LED Indicates power is being supplied to the system power supply units This LED is illuminated when the system is operating norm...
Страница 11: ...server in a rack environment Blinking blue UID has been activated using IPMI to locate the server in a rack environment Chassis Front The illustration below shows the features included on the front o...
Страница 12: ...eatures Item Features Description 1 Power Supply Two redundant power supply modules 2 LAN Four 10G Base T RJ45 LAN ports 3 USB Two USB 3 0 ports 4 IPMI LAN Dedicated LAN port for IPMI 5 COM Serial por...
Страница 13: ...I2C2 T SGPIO3 BP PWR2 BP PWR4 BP PWR3 BP PWR1 PSU1 PSU2 P1_NVMe1 P1_NVMe0 JNVI2C1 GPU PWR1 SXB3A SXB3B SXB3C SP1 BT1 JBT1 JRK1 JWD1 JVRM1 SXB1C SXB1B SXB1A SXB2 GPU PWR2 GPU PWR4 GPU PWR3 JSD1 JSD2 US...
Страница 14: ...NVMe devices JSD1 JSD2 SATA DOM power connectors 1 2 JSDCARD1 Micro SD card slot reserved for manufacturer use JTPM1 Trusted Platform Module Port 80 connector JUIDB2 UID Unit Identifier switch JVGA2...
Страница 15: ...Error LED_P1_E1 LED_P1_E2 Memory Fault LEDs for Memory Module P1_ E1 Memory Module P1_E2 Solid Red Memory Error LED_P1_F1 LED_P1_F2 Memory Fault LEDs for Memory Module P1_ F1 Memory Module P1_F2 Soli...
Страница 16: ...x4 x4 x4 x4 P1_NVMe2 P2_NVMe2 P2_NVMe1 3bit 5bit LAN DDR4 VGA PHY RTL8211F IPMI LAN RJ45 BMC AST2500 HWM SPI COM1 32MB BMC SPI FLASH PE LPC eSPI SPI USB 32MB BIOS SPI FLASH MUX TPM Header SPI USB2 0...
Страница 17: ...be prominently displayed on the outside of the shipping carton and mailed prepaid or hand carried Shipping and handling charges will be applied for all orders that must be mailed when service is compl...
Страница 18: ...ck Please read this section in its entirety before you begin the installation Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas wher...
Страница 19: ...from power surges and voltage spikes and to keep your system operating in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always keep...
Страница 20: ...ply connections other than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit in a rack you must take special pr...
Страница 21: ...installation instructions that came with the specific rack you are using Identifying the Rails The chassis package includes two rail assemblies Each assembly consists of three sections An inner rail t...
Страница 22: ...ompletely out of the rack when when the chassis is pulled out for servicing To mount the rail onto the chassis first release the inner rail from the outer rails 1 Pull the inner rail out of the outer...
Страница 23: ...are labeled 2 Place the inner rail firmly against the side of the chassis aligning the hooks on the side of the chassis with the holes in the inner rail 3 Slide the inner rail forward toward the front...
Страница 24: ...er rail adjusting the length until it just fits within the posts of the rack 5 Hang the hooks of the rear section of the outer rail onto the square holes on the rear of the rack Take care that the pro...
Страница 25: ...Align the inner rails of the chassis with the outer rails on the rack 3 Slide the inner rails into the outer rails keeping the pressure even on both sides When the chassis has been pushed completely...
Страница 26: ...s for a single person to remove it from the rack Have sufficient personnel or use a lift to support the chassis 1 Pull the chassis forward out the front of the rack until it stops 2 Press the release...
Страница 27: ...Please follow the procedures given in each section 3 1 Removing Power Use the following procedure to ensure that power has been removed from the system This step is necessary when removing or installi...
Страница 28: ...hese two screws are optional and will not impact functionality if they are not installed 2 Press the two release buttons and slide the cover toward the rear and lift off Check that all ventilation ope...
Страница 29: ...rocessor avoid touching or placing direct pressure on the LGA lands gold contacts Improper installation or socket misalignment can cause serious damage to the processor or CPU socket which may require...
Страница 30: ...s Manual 30 Overview of the Processor Heatsink Module The Processor Heatsink Module PHM contains a heatsink a processor carrier assembly Heatsink with Thermal Grease Processor Carrier Processor Proces...
Страница 31: ...w 2 Using the triangles as a guide carefully align and place Point A of the processor into Point A of the carrier Then gently flex the other side of the carrier for the processor to fit into Point B 3...
Страница 32: ...carrier assembly so the processor s gold contacts are facing up then align the triangle on the assembly with hole 1 of the heatsink Press the processor carrier assembly down The plastic clips of the...
Страница 33: ...tion This motherboard comes with a plastic protective cover on the CPU socket Remove it carefully to install the Processor Heatsink Module PHM CPU Socket with Plastic Protective Cover Socket Pins Remo...
Страница 34: ...hten screws 1 4 to assure even pressure The order of the screws is shown on the label on top of the heatsink To avoid damaging the processor or socket do not use a force greater than 12 lbf in when ti...
Страница 35: ...32 GB RDIMM 3Ds QRX4 N A 2H 64GB 8RX4 N A 4H 128GB LRDIMM QRx4 32 GB 64 GB LRDIMM 3Ds QRx4 N A 2H 64GB 8Rx4 N A 4H 128 GB DDR4 Memory Support for 82xx 62xx 52xx 42xx 32xx Processors Type Ranks Per DIM...
Страница 36: ...ixed in the same channel Mixing of LRDIMMs and RDIMMs is not allowed in the same channel across different channels and across different sockets Mixing of non 3DS and 3DS LRDIMM is not allowed in the s...
Страница 37: ...1 CPU2 P2 DIMMC1 P2 DIMMB1 P2 DIMMA1 2 CPUs 8 DIMMs CPU1 P1 DIMMB1 P1 DIMMA1 P1 DIMMD1 P1 DIMME1 CPU2 P2 DIMMB1 P2 DIMMA1 P2 DIMMD1 P2 DIMME1 2 CPUs 10 DIMMs CPU1 P1 DIMMC1 P1 DIMMB1 P1 DIMMA1 P1 DIMM...
Страница 38: ...IMMA2 P1 DIMMD2 P1 DIMME2 P1 DIMMD1 P1 DIMME1 P1 DIMMF2 P1 DIMMF1 P1 DIMMB1 P1 DIMMC1 P1 DIMMB2 P1 DIMMC2 CPU2 P2 DIMMA1 P2 DIMMA2 P2 DIMMD2 P2 DIMME2 P2 DIMMD1 P2 DIMME1 P2 DIMMF2 P2 DIMMF1 P2 DIMMB1...
Страница 39: ...1 M1 DCP 1 1 1 MM DCP M1 M1 M1 M1 DCP 1 1 1 AD MM DCP M3 M3 M3 M3 DCP 1 1 1 4 DCP 16 DIMM AD DCP M1 M1 M1 M1 M1 M1 M1 M1 DCP 2 2 1 AD App Direct MM Memory Mode M1 M2 M3 DRAM see Legend below Asymmetri...
Страница 40: ...g population is compliant with the PDG rules for the 82xx 62xx 52xx 42xx platform For each individual population use the same DDR4 DIMM in all slots For each individual population sockets are normally...
Страница 41: ...power from the system as described in Section 3 1 Follow the memory population sequence in the table above 1 Push the release tabs outwards on both ends of the DIMM slot to unlock it Notches Release T...
Страница 42: ...acing the Battery Begin by removing power from the system as described in section 3 1 1 Push aside the small clamp that covers the edge of the battery When the battery is released lift it out of the h...
Страница 43: ...y their removal from the chassis These carriers also help promote proper airflow Even carriers without drives must remain in the chassis for proper airflow Drive Carrier Indicators Each drive carrier...
Страница 44: ...age Drives Removing a Hot Swap Drive Carrier from the Chassis 1 Press the release button on the drive carrier which will extend the drive carrier handle 2 Use the drive carrier handle to pull the driv...
Страница 45: ...the carrier Align the drive in the carrier so that the screw holes line up Note that there are holes in the carrier marked SATA to aid in correct installation 3 Secure the drive to the carrier with f...
Страница 46: ...portant to connect the proper ports Otherwise some NVMe drives will not be detected Figure 3 5 NVMe Connections RSC U2N4 6 0 1 2 3 4 5 6 7 0 1 2 3 AOC 2UR6N4 I4XT BPN NVME3 216A S4 1x BPN NVME3 216EB...
Страница 47: ...and Slot and click Eject After ejecting the drive Status LED indicator turns green 3 Remove the drive Note that Device and Group are categorized by the CPLD design architecture The 2029U TN24R4T serv...
Страница 48: ...of an NVMe Drive There are two ways to check using IPMI Checking a Drive IPMI Server Health NVMe SSD Shows the temperatures of all NVMe drives as in Figure 3 4 IPMI Server Health Sensor Reading NVME_...
Страница 49: ...One M 2 socket supports PCIe and one supports SATA Several SSD lengths are supported 42mm 60mm 80mm or 110mm For each length there is an hole in the storage adapter card for a plastic standoff The fol...
Страница 50: ...install two M 2 SSDs you must remove the storage adapter card to move or add the standoff Removing the Storage Adapter Card to Mount M 2 SSDs 1 Remove the left WIO riser card as described in Figure 3...
Страница 51: ...h the IPMI Changing a System Fan 1 Determine which fan has failed using IPMI or if necessary open the chassis while the system is running Never run the server for long without the chassis cover 2 Push...
Страница 52: ...w through the chassis Pull all excess cabling out of the airflow path or use shorter cables The control panel LEDs display system heat status See Control Panel in Chapter 1 for details Overheating The...
Страница 53: ...uds Air shrouds concentrate airflow to maximize fan efficiency They do not require screws to install If you use an M 2 SSD a specialized shroud is installed instead of the standard shrouds Some GPUs r...
Страница 54: ...24R4T User s Manual 54 Figure 3 12 Installing the M 2 Air Shroud Installing a Specialized Air Shroud for M 2 Position the air shroud as illustrated in the figure below sliding the front notch over the...
Страница 55: ...module an LED displays the status Solid Green When illuminated indicates that the power supply is on Blinking Green When blinking indicates that the power supply is plugged in and turned off by the sy...
Страница 56: ...029U TN24R4T User s Manual 56 4 Push the new power supply module into the power bay until it clicks Replace with the same model 5 Plug the AC power cord back into the module Figure 3 14 Replacing the...
Страница 57: ...Double width full height full length x16 CPU1 2 Double width full height full length x16 CPU2 3 Low profile half length x8 CPU2 Full height 4 2 Low profile 2 5 Full length 10 5 Half length 6 6 This s...
Страница 58: ...flip switch with an arrow on it Flip open the appropriate switch to release the bracket then pull the bracket out of the chassis 3 Insert the expansion card s into the riser card slot s while aligning...
Страница 59: ...y remove the full height expansion card to access the low profile riser card slot pictured above 3 Insert the expansion card into the riser card slot while aligning the rear PCI shield into the chassi...
Страница 60: ...d at PSU1 and PSU2 Connect appropriate power supply units to these two headers to provide adequate power to your system Important To provide adequate power to the motherboard connect the both main pow...
Страница 61: ...Black 2 12V Red 3 Tachometer 4 PWM Control T SGPIO3 Header A Serial General Purpose Input Output header T SGPIO3 is located next to the TPM Port 80 on the motherboard This header is used to communicat...
Страница 62: ...ive is not installed in the system Internal Speaker Buzzer The Internal Speaker Buzzer SP1 is used to provide audible indications for various beep codes Internal Buzzer Pin Definitions Pin Definition...
Страница 63: ...ard into the expansion slot at JSDCARD1 for additional memory or OS image RAID Key Header Pin Definitions Pin Definition 1 Ground 2 RAID_KEY_PU 3 Ground 4 PCH_RAID_KEY NVMe SMBus Headers NVMe SMBus I2...
Страница 64: ...round Key Power On LED Control signal HDD LED Activity signal NIC1 LED Ground NIC2 LED Ground OH Fan Fail LED Ground Power Fail LED Ground Ground Ground 2 1 20 19 Power Button Pin Definitions JF1 Pin...
Страница 65: ...LED 8 OH Fan Fail LED LAN1 LAN2 LED Pin Definitions JF1 Pin Definition 9 NIC2 Activity LED 10 NIC2 Link LED 11 NIC1 Activity LED 12 NIC1 Link LED NIC1 NIC2 LAN1 LAN2 The NIC Network Interface Control...
Страница 66: ...connection is located on pins 15 and 16 of JF1 Power LED Pin Definitions JF1 Pin Definition 15 3 3V 16 Power LED NMI Button The non maskable interrupt button header is located on pins 19 and 20 of JF1...
Страница 67: ...e chassis rear provided by the Ultra add on card There is also a dedicated IPMI LAN port on the I O back panel For more information on IPMI refer to the IPMI User s Guide posted on our website at http...
Страница 68: ...ed Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clea...
Страница 69: ...og to reset the system if an application hangs Jumping pins 2 3 will generate a non maskable interrupt signal for the application that hangs Watch Dog must also be enabled in BIOS The default setting...
Страница 70: ...nk on and off Be sure to turn off the system and unplug the power cord s before removing or installing components Onboard Power LED Indicator LED Color Definition Off System Off power cable not connec...
Страница 71: ...ion Status LED_P1_A1 A2 Memory Fault LEDs for Memory Module P1_A1 A2 Red on memory errors LED_P1_B1 B2 Memory Fault LEDs for Memory Module P1_B1 B2 Red on memory errors LED_P1_C1 C2 Memory Fault LEDs...
Страница 72: ...power cables Supermicro SuperDOMs are backward compatible with regular SATA HDDs or SATA DOMs that need external power cables NVM Express Connections Four NVM Express ports are located on the motherbo...
Страница 73: ...upermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a USB flash drive o...
Страница 74: ...load the driver browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID c...
Страница 75: ...nother option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash drive or...
Страница 76: ...anagement Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server...
Страница 77: ...rm Management Interface IPMI IPMI is used to provide remote access monitoring and management There are several BIOS settings that are related to IPMI For general documentation and information on IPMI...
Страница 78: ...tion is selected it is highlighted in white Settings printed in Bold are the default values In the left frame a indicates a submenu Highlighting such an item and pressing the Enter key opens the list...
Страница 79: ...b key or the arrow keys to move between fields The date must be entered in MM DD YYYY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears...
Страница 80: ...this feature to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the norm...
Страница 81: ...cal drive as a USB drive USB CD DVD drives are not supported Disable this feature after the XHCI driver has been installed in Windows The options are Disabled and Enabled Port 61h Bit 4 Emulation Sele...
Страница 82: ...cessor Max Ration Processor Min Ration Microcode Revision L1 Cache RAM L2 Cache RAM L3 Cache RAM Processor 0 Version Processor 1 Version Hyper Threading All Available when supported by the CPU Select...
Страница 83: ...rformance The options are Enable and Disable Adjacent Cache Prefetch Available when supported by the CPU The CPU prefetches the cache line for 64 bytes if this feature is set to Disable The CPU prefet...
Страница 84: ...in the system The options are HW_ALL SW_ALL and SW_ANY Turbo Mode Available when Intel EIST Technology is enabled Select Enable to use the Turbo Mode to boost system performance The options are Disabl...
Страница 85: ...Bridge This feature allows the user to configure the following North Bridge settings UPI Configuration UPI Configuration The following information will be displayed Number of CPU Number of IIO Curren...
Страница 86: ...tion Integrated Memory Controller iMC Enforce POR Select Enable to enforce POR restrictions on DDR4 frequency and voltage programming The options are POR and Disable Memory Frequency Use this feature...
Страница 87: ...tions are Disable and Enable Memory Rank Sparing Select Enable to enable memory sparing support for memory ranks to improve memory performance The options are Disable and Enable If the item above Memo...
Страница 88: ...Configuration EV DFX Features When this feature is set to Enable the EV_DFX Lock Bits that are located on a proces sor will always remain clear during electric tuning The options are Disable and Enabl...
Страница 89: ...PCI E Port Max Payload Size Select Auto for the system BIOS to automatically set the maximum payload value for a PCI E device to enhance system performance The options are 128B 256B and Auto CPU2 Con...
Страница 90: ...U2N4 6 NVME1 Link Speed This feature allows the user to select PCI E support for the device installed in the system The options are Auto Gen 1 2 5 GT s Gen 2 5 GT s and Gen 3 8 GT s PCI E Port Link St...
Страница 91: ...e already been enqueued The options are Disable and Enable Intel VT for Directed I O VT d Intel VT for Directed I O VT d Select Enable to use Intel Virtualization Technology support for Direct I O VT...
Страница 92: ...e the hot plug support for PCIe root ports 1A 1D The options are Disable and Enable Intel VMD for Volume Management Device for PStack1 Select Enable to use the Intel Volume Management Device Technolog...
Страница 93: ...Enable to use the Intel Volume Management Device Technology for this stack The options are Disable and Enable If this feature is set to Enable the following features are available RSC U2N4 6 NVME1 VMD...
Страница 94: ...e options are Enabled Disabled and Auto XHCI Hand off This is a work around solution for operating systems that do not support XHCI Extensible Host Controller Interface hand off The XHCI ownership cha...
Страница 95: ...ill return to normal when the I O becomes active The options are Disable and Enable If the item above Configure SATA as is set to AHCI the following items will be displayed SATA Port 0 Port 7 This ite...
Страница 96: ...e installed SATA drive on the particular SATA port Model number of drive and capacity Software Preserve Support Hot Plug SATA Port 0 Port 7 Select Enabled to enable a SATA port specified by the user T...
Страница 97: ...pecified by the user The options are Disable and Enable Spin Up Device sSATA Port 0 Port 5 On an edge detect from 0 to 1 set this item to allow the PCH to initialize the device The options are Disable...
Страница 98: ...ion PCI Devices Common Settings Above 4G Decoding Available if the system supports 64 bit PCI decoding Select Enabled to decode a PCI device that supports 64 bit in the space above 4G Address The opti...
Страница 99: ...for system boot The options are Onboard and Offboard AOC 2UR6N4 i4XT SLOT1 PCI E 3 0 X16 OPROM For the three settings above select Disabled to deactivate the selected slot Legacy to acti vate the slot...
Страница 100: ...etwork Stack Select Enabled to enable UEFI Unified Extensible Firmware Interface for network stack support The options are Disabled and Enabled If this feature is set to Enable the following features...
Страница 101: ...he options are Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 and IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Serial Port 2 Configuration Se...
Страница 102: ...Character set Select VT100 to add color and function key support Select ANSI to use the Extended ASCII Character Set Select VT UTF8 to use UTF8 encoding to map Unicode characters into one or more byte...
Страница 103: ...a terminal and send it as text messages to a remote server The options are Disabled and Enabled Resolution 100x31 Select Enabled for extended terminal resolution support The options are Disabled and...
Страница 104: ...are 9600 19200 38400 57600 and 115200 bits per second Data Bits Use this feature to set the data transmission size for Console Redirection The options are 7 and 8 Parity A parity bit can be sent along...
Страница 105: ...ESCN and VT400 Redirection After BIOS POST Use this feature to enable or disable legacy console redirection after BIOS POST When this feature is set to BootLoader legacy console redirection is disabl...
Страница 106: ...Make sure that the same speed is used in both host computer and the client computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 57600 and 115200 bits...
Страница 107: ...etting to take effect The options are Disable and Enable If the item above is set to Enable the following items will become available for user s configuration The following Platform Configuration Regi...
Страница 108: ...or your system Http Boot One Time If this feature is set to Enabled the system will automatically boot into the HttpBoot setting that has been previously configured when it is powered up the first tim...
Страница 109: ...is feature allows the user to enter the unique name of the iSCSI Initiator in IQN format Once the name of the iSCSI Initiator is entered into the system configure the proper settings for the following...
Страница 110: ...ngs or select an action below The values below are examples yours may vary DIMM UID 8089 A2 1837 0000115D DIMM handle 0x0001 DIMM physical ID 0x0019 Manageability state Manageable Health state Healthy...
Страница 111: ...te 18 37 Manufacturing location 0xA2 Memory type Logical Non Volatile Device Memory bank label P0_Node0_Channel0_Dimm1 Data width label b 64 Total width b 72 Speed MHz 2666 Channel ID 0x0000 Channel p...
Страница 112: ...nd Received DDRT Power Fail Command Received PMIC 12V DDRT 1 2V Power Loss PLI Controller s FW State Flush Complete Write Data Flush Complete PM Idle Received Unlatched last shutdown status Unknown Se...
Страница 113: ...and 0 Sensor Type Media temperature Value 39 C Non critical threshold 82 Critical lower threshold 83 Critical upper threshold 83 Fatal threshold 85 State Normal Alarm enabled state Use this setting t...
Страница 114: ...g 50 Apply changes Press Enter to apply changes Update firmware Specify the firmware image to load on the DIMMs on the next system restart and select Update Current firmware version 01 00 00 5127 Sele...
Страница 115: ...e data policy settings on ALL the DIMMs First fast refresh state Disabled or Enabled Depending on the settings of the following feature Enable Disable first fast refresh Disabled or Enabled will be di...
Страница 116: ...goal config for Use this feature to select target to create goal configuration The options are Platform and Socket Reserved Enter a value 0 100 to reserve a percentage of the requested DIMM capacity t...
Страница 117: ...is feature to display details for or modify selected namespace View details for or modify selected namespace UUID 66B9E696 0E38 47B3 81 5E 99FFAFC26A23 ID 0x00000101 Name Press Enter to type in a name...
Страница 118: ...Remaining to use the maxi mum available capacity Set this feature to Manual to enter the capacity manually Units Use this feature to change the units of the input namespace capacity The options are B...
Страница 119: ...d Config diagnostics Select Enabled to enable the platform configuration diagnostics test The options are Disabled and Enabled FW diagnostics Select Enabled to enable the firmware diagnostics test The...
Страница 120: ...re Auto Auto_10 B MB MiB GB GiB TB and TiB App Direct settings This feature is to view or modify the interleaving settings for creating App Direct capacity The default setting is 4KB_4KB Recommended A...
Страница 121: ...98 Child 0 Healthy Intel R 10GbE Driver 7 0 19 x64 Healthy Controller 63f38f18 Child 0 Healthy Intel R Ethernet Controller 10 Gigabit X540 AT2 Healthy Controller 63f37398 Child 0 Healthy Intel R Ether...
Страница 122: ...abled and Enabled Erasing Settings Erase Event Log If No is selected data stored in the event log will not be erased Select Yes Next Reset data in the event log will be erased upon next system reboot...
Страница 123: ...plicate event must happen before the MECI counter is incremented This is a numeric value The default value is 1 METW The Multiple Event Time Window METW defines number of minutes must pass between dup...
Страница 124: ...the IPMI firmware installed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Disabled and Enabled Erasin...
Страница 125: ...llowing items will become available for user s configuration Configuration Address Source This feature allows the user to select the source of the IP address for this computer If Static is selected yo...
Страница 126: ...ng is Enabled If the item above is set to Enabled the following items will become available for user s configuration Configuration Address Source This feature allows the user to select the source of t...
Страница 127: ...nter to set the user password which is required to enter the BIOS setup utility The length of the password should be from 3 characters to 20 characters long Password Check Select Setup for the system...
Страница 128: ...lts Select Enabled to install the default Secure Boot keys set by the manufacturer The options are Disabled and Enabled Enroll all Factory Default Keys Select Yes to install all default secure keys se...
Страница 129: ...res Forbidden Signature Database DBX contains forbidden certificates and digital signa tures Select Set New to load the DBX from the manufacturer s defaults Select Append to add the DBX from the manuf...
Страница 130: ...se this item to enable the EFI boot support The options are Disabled and Enabled FIXED BOOT ORDER Priorities This option prioritizes the order of bootable devices that the system to boot from Press En...
Страница 131: ...eature to remove a pre defined boot device from which the system will boot during startup The options are Select one to Delete and UEFI Built in EFI Shell UEFI Application Boot Priorities This feature...
Страница 132: ...ard Changes and Exit from the Exit menu and press Enter Save Changes and Reset After completing the system configuration changes select this option to save the changes you have made This will reset re...
Страница 133: ...but not for maximum performance Save As User Defaults To set this feature select Save as User Defaults from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup fo...
Страница 134: ...their corresponding beep codes encountered by users BIOS Error Beep POST Codes Beep Code Error Message Description 1 short Refresh Circuits have been reset Ready to power up 5 short 1 long Memory erro...
Страница 135: ...for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis The...
Страница 136: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...
Страница 137: ...rken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan...
Страница 138: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...
Страница 139: ...ntes del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l ins...
Страница 140: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...
Страница 141: ...kabels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment W...
Страница 142: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...
Страница 143: ...o a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc...
Страница 144: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...
Страница 145: ...aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All c...
Страница 146: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...
Страница 147: ...Advertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques...
Страница 148: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...
Страница 149: ...nale elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accor...
Страница 150: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...
Страница 151: ...destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient...
Страница 152: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSE Supermicro Supermicro UL CSA UL CSA Supermicro U...
Страница 153: ...r le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto u...
Страница 154: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...
Страница 155: ...swap 2 5 SATA M 2 1 M 2 NVMe 2242 2260 2280 22110 1 M 2 SATA 2242 2260 2280 22110 via optional SATA cable PCI Expansion Slots Two full height x16 PCI E slots One low profile x8 PCI E 3 0 slot Motherbo...
Страница 156: ...SPR 32 and AS NZS CISPR 32 Environmental Directive 2011 65 EU and DELEGATED DIRECTIVE EU 2015 863 and Directive 2012 19 EU Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Mar...
Страница 157: ...he recovery block contains critical BIOS codes including memory detection and recovery codes for the user to flash a healthy BIOS image if the original main BIOS image is corrupted When the system pow...
Страница 158: ...a different machine copy the Super ROM binary image file into the Root directory of a USB device or a writable CD DVD Note 1 If you cannot locate the Super ROM file in your drive disk visit our websi...
Страница 159: ...you want to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 4 When the screen as shown above displays use the arrow keys to select the item Proceed with...
Страница 160: ...oot to enter the BIOS Setup utility From the top of the tool bar select Boot to enter the submenu From the submenu list select Boot Option 1 as shown below Then set Boot Option 1 to UEFI AP UEFI Built...
Страница 161: ...rupt this process until the BIOS flashing is complete 9 The screen above indicates that the BIOS update process is complete When you see the screen above unplug the AC power cable from the power suppl...
Страница 162: ...staff You can download a crash dump of status information using IPMI The IPMI manual is available at https www supermicro com solutions IPMI cfm Check IPMI Error Log 1 Access the IPMI web interface 2...
Страница 163: ...mains in a failed state Do not check this box until after the dump file has been sent to Support Downloading the Crash Dump File 1 In the IPMI interface click the Miscellaneous tab then the Trouble Sh...
Страница 164: ...dels 2 Double width full height full length x16 CPU1 x8 CPU1 Depends on model 5 6 Full height full length x8 CPU2 All models 7 8 Full height full length x8 CPU2 All models Only supported in special ci...
Страница 165: ...o release the bracket then pull the bracket out of the chassis For the Ultra riser center bracket there is a thumbscrew to a standoff in the chassis center 3 Insert the GPU into the riser card slot wh...
Страница 166: ...Left side GPUs into the Riser Card Bracket Figure F 4 Inserting the Middle and Right side GPUs into the Riser Card Bracket Rear L Bracket for Left side GPU Rear L Bracket for Middle GPU Rear L Bracke...
Страница 167: ...eft side GPU a middle GPU or a right side GPU the front bracket is pre installed on the riser card bracket Figure F 6 Attaching the Front Bracket for Middle and Right side GPUs Bracket for Middle GPU...
Страница 168: ...ront end of the GPU into the throat of the air shroud Then align and insert the riser card into the motherboard slot while aligning the bracket into the chassis 8 Secure the bracket into the chassis A...
Страница 169: ...the Upper Left side Position 5 6 Break off the necessary portions of the shroud to allow for cables In particular remove some tabs on the top as indicated Position the shroud as shown in Figure F 3 T...
Страница 170: ...standoff in the center of the chassis The left wall of the shroud fits next to CPU2 Routing the GPU power cables You will likely have to route the cables to the motherboard connector before fully sea...
Страница 171: ...w for cables Position the shroud as shown The right side wall of the shroud should not cover the right most DIMM P1 DIMMC1 The hole near the center of the shroud fits over the standoff in the center o...
Страница 172: ...apid Storage Technology enterprise Intel RSTe Driver for Linux Windows https downloadcenter intel com download 28108 Intel Virtual RAID on CPU Intel VROC and Intel Rapid Storage Technology enterprise...
Страница 173: ...RK1 The key options are Intel VROC Keys VROC Package Description Part Number Intel MM Number Standard RAID 0 1 10 Supports 3rd party SSDs AOC VROCSTNMOD 951605 Premium RAID 0 1 5 10 Supports 3rd party...
Страница 174: ...CPU2 1029U T VMD Config for PStack0 not needed 6019U TN4 2029U T 2029U E1C 2029UZ T 6029U T 6029U E1C 6029UZ T VMD Config for PStack0 VMD Config for PStack1 1029U TN10 VMD Config for PStack1 VMD Confi...
Страница 175: ...BIOS VMD Setting Examples for Ultra Servers For 2029U TN24R4T populated with 24 U 2 NVMe drives CPU1 Configuration CPU2 Configuration CPU2 Configuration CPU1 Configuration For 2029U TR or 2029U E1CR...
Страница 176: ...RAID on CPU All Intel VMD Controllers Create RAID Volume 9 Set Name 10 Set RAID Level 11 If cross controller RAID is required select Enable RAID spanned over VMD Controller as shown in Figure G 4 12...
Страница 177: ...e device Hot plug Physically install the device ESXi will automatically discover NVMe SSDs but a manual scan may be required in some cases Related Information Links 1 https kb vmware com s article 215...