Chapter 4: BIOS

93

Bits Per second

Use this feature to set the transmission speed for a serial port used in Console Redirection. 
Make sure that the same speed is used in the host computer and the client computer. A 
lower transmission speed may be required for long and busy lines. The options are 9600, 
19200, 38400, 57600 and 

115200 

(bits per second). 

Data Bits

Use this feature to set the data transmission size for Console Redirection. The options are 
7 (Bits) and 

8 (Bits)

Parity

A parity bit can be sent along with regular data bits to detect data transmission errors. 
Select Even if the parity bit is set to 0, and the number of 1's in data bits is even. Select 
Odd if the parity bit is set to 0, and the number of 1's in data bits is odd. Select None if you 
do not want to send a parity bit with your data bits in transmission. Select Mark to add a 
mark as a parity bit to be sent along with the data bits. Select Space to add a Space as a 
parity bit to be sent with your data bits. The options are 

None

, Even, Odd, Mark and Space.

Stop Bits

A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard serial 
data communication. Select 2 Stop Bits if slower devices are used. The options are 

1

 and 2.

Flow Control

Use this feature to set the flow control for Console Redirection to prevent data loss caused 
by buffer overflow. Send a "Stop" signal to stop sending data when the receiving buffer 
is full. Send a "Start" signal to start data-sending when the receiving buffer is empty. The 

options are 

None

 and Hardware RTS/CTS.

VT-UTF8 Combo Key Support

Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100 terminals. 
The options are 

Enabled

 and Disabled

.

Recorder Mode

Select Enabled to capture the data displayed on a terminal and send it as text messages 
to a remote server. The options are 

Disabled

 and Enabled.

Resolution 100x31

Select Enabled for extended-terminal resolution support. The options are Disabled and 

Enabled

Legacy OS Redirection Resolution

Use this feature to select the number of rows and columns used in Console Redirection 
for legacy OS support. The options are 

80x24

 and 80x25.

Содержание SuperServer 2029TP-HC0R

Страница 1: ...USER S MANUAL Revision 1 0b SuperServer 2029TP HTR 2029TP HC1R 2029TP HC0R...

Страница 2: ...n a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful...

Страница 3: ...le below SuperServer 2029TP HTR HC1R HC0R Model Variations Server Model Node Backplane 2029TP HTR BPN ADP 6SATA3P 2029TP HC1R BPN ADP S3108L H6IRP 2029TP HC0R BPN ADP S3008L L6IP Please refer to the 2...

Страница 4: ...y be encountered when performing a procedure Warning Indicates important information given to prevent equipment property damage or personal injury Warnings Special attention should be given to the fol...

Страница 5: ...lation 2 1 Overview 17 2 2 Preparing for Setup 17 Choosing a Setup Location 17 Rack Precautions 17 Server Precautions 18 Rack Mounting Considerations 18 Ambient Operating Temperature 18 Airflow 18 Mec...

Страница 6: ...Form the Processor Heatsink Module PHM 31 Preparing the CPU Socket for Installation 32 Removing the Dust Cover from the CPU Socket 32 Installing the Processor Heatsink Module PHM 33 Removing the Proce...

Страница 7: ...for a RAID System 66 Installing Windows to a Non RAID System 66 5 2 Driver Installation 67 5 3 SuperDoctor 5 68 5 4 IPMI 69 Chapter 6 BIOS 6 1 Introduction 70 Starting the Setup Utility 70 6 2 Main Se...

Страница 8: ...Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermicro nl...

Страница 9: ...4 2U Twin Square Backplane supports 24 SAS3 SATA3 2 5 HDD BPN SAS3 217HQ2 1 Backplane adapter card with six 6 HDD ports BPN ADP 6SATA3P HTR BPN ADP S3108L H6IRP HC1R BPN ADP S3008L L6IP HC0R 4 Hot sw...

Страница 10: ...nds on the processors used in the system Note 2 For the latest CPU memory updates please refer to our website at http www supermicro com products motherboard Chipset Intel C621 chipset Expansion Slots...

Страница 11: ...twork activity on either LAN1 or LAN2 when flashing 3 Information LED See the following table for the status shown by this LED 4 UID Button When used with a UID compatible motherboard the UID button i...

Страница 12: ...ni 2U chassis See the illustration below for the features included on the front of the chassis Information LED Status Description Continuously on and red An overheat condition has occurred This may be...

Страница 13: ...2 Bay for Power Supply 3 Rear I O Ports 4 See Chapter 4 for details on the rear I O ports 4 SIOM Module 4 Installed SIOM module see chapter 3 for details on the SIOM module Figure 1 3 Chassis Rear Vi...

Страница 14: ...DIMME1 P2 DIMMF1 P4 JHS1 JPME1 JBT1 FAN3 SXB4 SXB1 UID_LED1 JUIDB1 JSIOM1 SXB3_1 SXB2 SXB3_2 I SATA5 JCPLD1 JRK1 BT1 JTPM1 JSDCARD1 PHY I SATA4 HDD_LED I SATA0 3 S SATA0 5 IPMI_LAN CPU1 PCI E 3 0 X16...

Страница 15: ...devices JSDCARD1 BMC_SD card header JSIOM1 Super I O Module used as CPU1 PCI E 3 0 x16 slot JTPM1 Trusted Platform Module Port 80 connector JUIDB1 UID Unit Identifier switch SXB1 for S SATA 0 5 PCI E...

Страница 16: ...00 BMC 5 RMII NCSI COM1 VGA CONN BMC Boot Flash DDR4 P1 P0 P0 UPI PCI E X16 DMI3 SXB1 RAID ADP PCI E X8 PCI E X16 2 MI D 2 I M D SIOM PCI E X8 PCI E X16 PCI E X16 1C 2 3 1 3A 6 7 8 9 UPI 2 SFI UPLINK...

Страница 17: ...e situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated Leave enough clearance in front of the rack so that you ca...

Страница 18: ...ntain proper cooling Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi unit rack assembly the ambient operating temperature of the rack environment may be gr...

Страница 19: ...t the bottom of the rack If the rack is provided with stabilizing devices install the stabilizers before mounting or servicing the unit in the rack 2 3 Installing the Rails There are a variety of rack...

Страница 20: ...ull the system from a rack only Slide rail mounted equipment is not to be used as a shelf or a work space Inner Rail Rail Assembly Shown with Rails Retracted This Side Faces Outward Locking Tab Middle...

Страница 21: ...d out for servicing Releasing the Inner Rail Use the procedure below to release the inner rails from the outer rails Releasing Inner Rail from the Outer Rails Figure 2 2 1 Identify the left and right...

Страница 22: ...rail firmly against the side of the chassis aligning the hooks on the side of the chassis with the holes in the inner rail 3 Slide the inner rail forward toward the front of the chassis until the rai...

Страница 23: ...il 2 Push the middle rail back into the outer rail 3 Hang the hooks of the front of the outer rail onto the slots on the front of the rack If necessary use screws to secure the outer rails to the rack...

Страница 24: ...sition of the middle rail 4 Align the chassis inner rails with the front of the middle rails 5 Slide the inner rails on the chassis into the middle rails keeping the pressure even on both sides until...

Страница 25: ...t the AC power cord s from the power strip or outlet If your system has more than one power supply remove the AC power cords from all power supply modules 3 Disconnect the power cord s from the power...

Страница 26: ...adding removing or changing any hardware components Please note that the processor and heatsink should be assembled together first to form the Processor Heatsink Module PHM and then install the entire...

Страница 27: ...l 27 The Skylake Series Processor Note All graphics drawings and pictures shown in this manual are for illustration only The components that came with your machine may or may not look exactly the same...

Страница 28: ...ontains 1 the Intel SKX processor 2 the narrow processor clip 3 the dust cover and 4 the CPU socket 3 Dust Cover 4 CPU Socket 1 SKX Processor Note Be sure to cover the CPU socket with the dust cover w...

Страница 29: ...29 Overview of the Processor Heatsink Module PHM The Processor Heatsink Module PHM contains 1 a heatsink 2 a narrow processor clip and 3 the SKX processor 1 Heatsink 2 Narrow processor clip 3 SKX Proc...

Страница 30: ...processor clip by sliding notch B of the CPU into notch B of the processor clip and sliding notch C of the CPU into notch C of the processor clip 4 Examine all corners of the CPU to ensure that it is...

Страница 31: ...graphic Note a larger hole and plastic mounting clicks located next to the hollow triangle Also locate another set of mounting clicks and a larger hole at the diagonal corner of the same reverse side...

Страница 32: ...ate These components are pre installed on the motherboard before shipping CPU Socket w Dust Cover On Dusk Cover SKX CPU Socket Removing the Dust Cover from the CPU Socket Remove the dust cover from th...

Страница 33: ...PHM right side up and you will see a triangle marked on the processor clip at the same corner of hollow triangle 3 Carefully align pin 1 the triangle on the the PHM against pin 1 the triangle on the...

Страница 34: ...e removing the processor heatsink module PHM unplug power cord from the power outlet 1 Using a T30 Torx bit screwdriver turn the screws on the PHM counterclockwise to loosen them from the socket start...

Страница 35: ...e the first DIMM module on the blue memory slot which is the first memory slot of a memory channel and then populate the second DIMM in the black slot if 2DPC memory configuration is used 3 Using unba...

Страница 36: ...DIMM in another channel reduces performance It is not recommended for Supermicro systems In dual CPU configurations memory must be installed in the slots associated with the installed CPUs Guidelines...

Страница 37: ...DIMMA1 P1 DIMMA2 P1 DIMMD1 P1 DIMME1 P1 DIMMF1 1 CPU 8 DIMMs Unbalanced not recommended CPU1 P1 DIMMC1 P1 DIMMB1 P1 DIMMA1 P1 DIMMA2 P1 DIMMD2 P1 DIMMD1 P1 DIMME1 P1 DIMMF1 When 2 CPUs are used Memory...

Страница 38: ...3 Maintenance and Component Installation CPU1 P2 DIMMA1 P2 DIMMA2 P2 DIMMD2 P2 DIMMD1 P2 DIMME1 P2 DIMMF1 P2 DIMMB1 P2 DIMMC1 P1 DIMMD2 CPU2 P1 DIMMD1 P1 DIMME1 P1 DIMMF1 P1 DIMMA2 P1 DIMMA1 P1 DIMMB1...

Страница 39: ...ower from the system as described in Section 3 1 Follow the memory population sequence in the table above 1 Push the release tabs outwards on both ends of the DIMM slot to unlock it Notches Release Ta...

Страница 40: ...must be replaced only with the same or an equivalent type recommended by the manufacturer CR2032 OR Figure 3 2 Installing the Onboard Battery Motherboard Battery The motherboard uses non volatile memo...

Страница 41: ...e node drawers Each motherboard node controls a set of six hard drives Note that if a motherboard node drawer is pulled out of the chassis the hard drives associated with that node will power down as...

Страница 42: ...the chassis Both procedures may be done without removing power from the system Removing a Hot Swap Drive Carrier 1 Push the release button on the carrier 2 Swing the handle fully out 1 2 Cauton Except...

Страница 43: ...with the screws provided then push the carrier completely into the drive bay You should hear a click when the drive is fully inserted This indicates that the carrier has been fully seated and connect...

Страница 44: ...Activity LED Blue Solid On SAS NVMe drive installed Blue Blinking I O activity Status LED Red Solid On Failed drive for SAS SATA NVMe with RSTe support Red Blinking at 1 Hz Rebuild drive for SAS SATA...

Страница 45: ...no need to uninstall any other parts inside the system when replacing fans and no tools are required for installation These fans are NOT redundant hot plug and must be replaced when they fail It is v...

Страница 46: ...ith the chassis cover open 2 After determining which fan needs to be replaced power down the associated node 3 Remove the node drawer from the chassis 4 Remove the failed fan s power cable from the ba...

Страница 47: ...Make sure that the motherboard expansion card if applicable and all components are properly installed in each motherboard node 2 If necessary move any cables that interfere with the air shroud placeme...

Страница 48: ...cer plate to the drawer and set them aside for later use 4 Remove the adapter card and spacer plate from the motherboard drawer 5 Set the spacer plate aside for later use Installing the Adapter Card 1...

Страница 49: ...on Card The SC217 chassis supports expansion cards Riser cards are used to mount the expansion cards The SC217HQ model accommodate one low profile card per node for a total of four in the chassis PCI...

Страница 50: ...he chassis 2 Remove the riser card bracket removing the screw on the back of the drawer 3 Align the riser card mounting hole to the bracket standoff and secure the riser card to the bracket using the...

Страница 51: ...stalled push it into the motherboard slot 4 Slide the expansion card into the riser card slot and fit the expansion card shield into the opening in the rear of the node drawer 5 Close the PCI slot cli...

Страница 52: ...SM four SFP 10GbE ports supported by an Intel XL710 BM1 controller AOC MTG i2TM two RJ45 10GbE ports supported by an Intel X550 controller AOC MTG i2TM two RJ45 10GbE ports supported by an Intel X550...

Страница 53: ...29TP HTR HC1R HC0R User s Manual 53 2 Remove the two screws from the Pulling Ear and one screw from the side of the SIOM mounting bracket Figure 3 13 Removing the Screws from the Pulling Ear and Side...

Страница 54: ...nance and Component Installation 3 Flip the chassis and take out the two screws securing the sled back 4 Flip back the chassis upward and take out the SIOM bracket Figure 3 14 Removing the Screws Secu...

Страница 55: ...SuperServer 2029TP HTR HC1R HC0R User s Manual 55 5 Remove the two screws holding the SIOM module and carefully remove the module out of the chassis Figure 3 15 Removing the SIOM Bracket...

Страница 56: ...ounds of torgue and a slow speed if using a power tool or manually using a screwdriver 7 Flip the chassis and secure the sled back using its two screws from step 3 8 Put the Pulling Ear back in place...

Страница 57: ...the chassis to the rack then grasp the two handles on either side and pull the system straight out until it locks you will hear a click 2 Next remove the top chassis cover as described in Section 3 2...

Страница 58: ...58 Chapter 3 Maintenance and Component Installation Figure 3 16 Removing Replacing a Power Supply Release Tab...

Страница 59: ...iate power cable here to provide adequate power to your system 4 2 Headers and Connectors Onboard Fan Header An onboard fan header FAN3 is located next to COM port COM1 on the motherboard This is a 4...

Страница 60: ...definitions I SATA 3 0 and S SATA 3 0 Ports The X11DPT PS has six I SATA 3 0 ports I SATA0 3 I SATA4 I SATA5 and six S SATA S SATA0 5 on the motherboard These SATA ports are supported by the Intel C62...

Страница 61: ...D_LED1 JUIDB1 JSIOM1 SXB3_1 SXB2 SXB3_2 I SATA5 JCPLD1 JRK1 BT1 JTPM1 JSDCARD1 PHY I SATA4 HDD_LED I SATA0 3 S SATA0 5 IPMI_LAN CPU1 PCI E 3 0 X16 CPU2 PCI E 3 0 X8 CPU1 PCI E 3 0 X8 CPU2 PCI E 3 0 X1...

Страница 62: ...in Definition 1 DCD 6 DSR 2 RXD 7 RTS 3 TXD 8 CTS 4 DTR 9 RI 5 Ground 10 N A Back Panel USB 3 0 Pin Definitions Pin Definition Pin Definition 1 VBUS 10 Power 2 D 11 USB 2 0 Differential Pair 3 D 12 4...

Страница 63: ...f service Note UID can also be triggered via IPMI on the motherboard For more information on IPMI please refer to the IPMI User s Guide posted on our website at http www supermicro com UID Switch Pin...

Страница 64: ...moved Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally c...

Страница 65: ...activity while the other Link LED may be green amber or off to indicate the speed of the connection Refer to the tables below for more information Dedicated IPMI LAN LEDs In addition to LAN1 and LAN2...

Страница 66: ...a USB port on the system Note for older legacy OS s please use a method to slipstream the drivers 3 Select the partition on the drive in which to install Windows 4 Browse the USB folder for the proper...

Страница 67: ...er option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard here where you may download individual drivers and utilities to your hard dr...

Страница 68: ...rk Management Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Se...

Страница 69: ...orm Management Interface IPMI IPMI is used to provide remote access monitoring and management There are several BIOS settings that are related to IPMI For general documentation and information on IPMI...

Страница 70: ...used such as F1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out option...

Страница 71: ...ystem Time Use this feature to change the system date and time Highlight System Date or System Time using the arrow keys on the keyboard Press the Tab key or the arrow keys to move between fields The...

Страница 72: ...n of the CPLD Complex Programmable Logical Device used in the system Memory Information Total Memory This item displays the total size of memory available in the system Memory Speed This item displays...

Страница 73: ...to wait until the F1 key is pressed if an error occurs The options are Disabled and Enabled INT19 Trap Response Interrupt 19 is the software interrupt that handles the boot disk function When this ite...

Страница 74: ...Power On for the system power to be turned on after a power loss Select Last State to allow the system to resume its last power state before a power loss The options are Power On Stay Off and Last Sta...

Страница 75: ...enable Execute Disable Bit support which will allow the processor to designate areas in the system memory where an application code can execute and where it cannot thus preventing a worm or a virus fr...

Страница 76: ...is set to Enable the DCU Data Cache Unit streamer prefetcher will prefetch data streams from the cache memory to the DCU Data Cache Unit to speed up data accessing and processing for CPU performance...

Страница 77: ...aster than the frequency specified by the manufacturer The options are Disable and Enable Hardware PM Power Management State Control Hardware P States If this feature is set to Disable hardware will c...

Страница 78: ...No Limit and Auto CPU T State Control Software Controlled T States If this feature is set to Enable CPU throttling settings will be supported by the software of the system The options are Disable and...

Страница 79: ...The options are Disable Auto Enable for Remote InvItoM Hybrid Push InvItoM AllocFlow Enable for Remote InvItoM Hybrid AllocNonAlloc and Enable for Remote InvItoM and Remote WViLF Isoc Mode Select Enab...

Страница 80: ...2 DIMMA2 to P2 DIMMF1 P2 DIMMF2 Memory RAS Reliability_Availability_Serviceability Configuration Use this submenu to configure the following Memory RAS settings Static Virtual Lockstep Mode Select Ena...

Страница 81: ...ctions to the requestor the original source When this item is set to Enable the IO hub will read and write back one cache line every 16K cycles if there is no delay caused by internal processing By us...

Страница 82: ...gures the PCI E Bifuraction setting for a PCI E port specified by the user The options are x16 and Auto CPU1 PCI E Br0D00F0 Port 0 DMI Available for CPU 1 Configuration only Link Speed This feature co...

Страница 83: ...completed prior to other transactions that have already been enqueued The options are Disable and Enable Intel VT for Directed I O VT d Intel VT for Directed I O VT d Select Enable to use Intel Virtua...

Страница 84: ...s to disable the PCI E Completion Time out settings The options are Yes No and Per Port South Bridge The following South Bridge information will display USB Module Version USB Devices Legacy USB Suppo...

Страница 85: ...ct AHCI to configure a SATA drive specified by the user as an AHCI drive Select RAID to configure a SATA drive specified by the user as a RAID drive The options are AHCI and RAID Note This item is hid...

Страница 86: ...nected to a Solid State drive or a Hard Disk Drive The options are Hard Disk Drive and Solid State Drive PCH sSATA Configuration When this submenu is selected AMI BIOS automatically detects the presen...

Страница 87: ...lot without shutting down the system The options are Disable and Enabled Spin Up Device On an edge detect from 0 to 1 set this item to allow the sSATA device installed on the sSATA port specified by t...

Страница 88: ...re Auto 128 Bytes 256 Bytes 512 Bytes 1024 Bytes 2048 Bytes and 4096 Bytes MMCFG Base This feature determines the lowest MMCFG Memory Mapped Configuration base assigned to PCI devices The options are...

Страница 89: ...nd Disabled Ipv6 PXE Support Select Enabled to enable Ipv6 PXE boot support If this feature is disabled it will not create the Ipv6 PXE boot option The options are Disabled and Enabled Ipv6 HTTP Suppo...

Страница 90: ...led Device Settings This feature displays the base I O port address and the Interrupt Request address of a serial port specified by the user Note This item is hidden when Serial Port 1 is set to Disab...

Страница 91: ...bit can be sent along with regular data bits to detect data transmission errors Select Even if the parity bit is set to 0 and the number of 1 s in data bits is even Select Odd if the parity bit is set...

Страница 92: ...ected legacy Console Redirection is disabled before booting the OS When the option Always Enable is selected legacy Console Redirection remains enabled upon OS bootup The options are Always Enable and...

Страница 93: ...our data bits The options are None Even Odd Mark and Space Stop Bits A stop bit indicates the end of a serial data packet Select 1 Stop Bit for standard serial data communication Select 2 Stop Bits if...

Страница 94: ...ergency Management Services EMS The submenu allows the user to configure Console Redirection settings to support Out of Band Serial Port management Console Redirection for EMS Select Enabled to use a...

Страница 95: ...CPI power management settings for your system NUMA Support Available when the OS supports this feature Select Enabled to enable Non Uniform Memory Access support to enhance system performance The opti...

Страница 96: ...system data integrity Your system will reboot to carry out a pending TPM operation The options are None and TPM Clear Note Your system will reboot to carry out a pending TPM operation Platform Hierar...

Страница 97: ...above Select Enabled for Platform Hierarchy Randomization support which is used only during the platform developmental stage This feature cannot be enabled in the production platforms The options are...

Страница 98: ...029TP HTR HC1R HC0R User s Manual 98 Intel Virtual RAID on CPU When this submenu is selected and the RAID devices are detected the BIOS screen displays the following items Intel VROC with VMD Technolo...

Страница 99: ...vent Log Select Enabled to enable SMBIOS System Management BIOS Event Logging during system boot The options are Enabled and Disabled Erasing Settings Erase Event Log Select Enabled to erase all error...

Страница 100: ...n minutes the multiple event counter should wait before generating a new event log Enter a number between 0 to 99 The default setting is 60 Note Please reboot the system for the changes to take effect...

Страница 101: ...on will display BMC Firmware Revision This feature indicates the IPMI firmware revision used in your system Status of BMC This feature indicates the status of the BMC Baseboard Management Controller i...

Страница 102: ...ress code Note After making changes on a setting be sure to reboot the system for the changes to take effect BMC Network Configuration The following items will be displayed IPMI LAN Selection This fea...

Страница 103: ...ture to select the IP address source for this computer If Static is selected you will need to know the IP address of this computer and enter it to the system manually in the field If DHCP is selected...

Страница 104: ...assword should be from 3 characters to 20 characters long User Password Use this feature to set the user password which is required to enter the BIOS setup utility The length of the password should be...

Страница 105: ...om CMS Support Select Enbabled for CMS support to enhance system performance The options are Enabled and Disabled Key Management Provision Factory Default Keys Select Enabled to install all manufactur...

Страница 106: ...thorized Signatures for the system These values also indicate the size the keys numbers and the key source of the Authorized Signatures The options are Set New and Append Secure Boot Variable Size Key...

Страница 107: ...elect Use this feature to select the type of devices to be used for system boot The options are Legacy UEFI Unified Extensible Firmware Interface and Dual Legacy to EFI Support Select Enabled for the...

Страница 108: ...s set to UEFI the following items will be display for configuration Boot Option 1 Boot Option 8 Add New Boot Option This feature allows the user to add a new boot option to the boot priority features...

Страница 109: ...e path of the driver that the new boot option is added to Create After the driver option name and the file path are set press Enter to enter to submenu and click OK to create the new boot option drive...

Страница 110: ...e computer Select Discard Changes and Exit from the Exit menu and press Enter Save Changes and Reset When you have completed the system configuration changes select this option to leave the BIOS setup...

Страница 111: ...faults To set this feature select Save as User Defaults from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this...

Страница 112: ...rror occurs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list on t...

Страница 113: ...m support manuals AMI BIOS POST Codes User s Guide When BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot process a diagnostic...

Страница 114: ...ment for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassi...

Страница 115: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...

Страница 116: ...werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers...

Страница 117: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...

Страница 118: ...rientes del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l...

Страница 119: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...

Страница 120: ...oomkabels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipmen...

Страница 121: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...

Страница 122: ...ceso a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L a...

Страница 123: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...

Страница 124: ...kant aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection A...

Страница 125: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...

Страница 126: ...ng Advertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriqu...

Страница 127: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...

Страница 128: ...tionale elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled ac...

Страница 129: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...

Страница 130: ...os destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soie...

Страница 131: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSE Supermicro Supermicro UL CSA UL CSA Supermicro U...

Страница 132: ...u sur le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el produc...

Страница 133: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...

Страница 134: ...xpress 3 0 x16 slot supported by CPU2 for use of I SATA 0 3 devices SXB2 One 1 PCI Express 3 0 x16 slot supported by CPU1 SXB3_1 One 1 PCI Express 3 0 x8 slot supported by CPU2 SXB3_2 One 1 PCI E 3 0...

Страница 135: ...1 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe Other VCCI CISPR 32 and AS NZS CISPR 32 Environmental Directive 2011 65 EU and Directive 2012 19 EU Perchlora...

Страница 136: ...ck a main BIOS image The boot block contains critical BIOS codes including memory detection and recovery codes for the user to flash a new BIOS image if the original main BIOS image is corrupted When...

Страница 137: ...e volumes of folders and files stored in the device To perform UEFI BIOS recovery using a USB attached device follow the instructions below 1 Using a different machine copy the Super ROM binary image...

Страница 138: ...the screen or a similar screen below otherwise it will trigger a system reboot 4 After locating the new BIOS binary image the system will enter the BIOS Recovery menu as shown below Note At this poin...

Страница 139: ...erent system extract the BIOS package into a USB flash drive Proceed with flash update and press the Enter key You will see the BIOS recovery progress as shown in the screen below Note Do not interrup...

Страница 140: ...o to the directory that contains the BIOS package you extracted earlier from Step 7 Enter flash nsh BIOSname at the prompt to start the BIOS update process Note Do not interrupt this process until the...

Отзывы: