background image

USER’S MANUAL 

Revision 1.0

a

SuperServer

®

2029P-C1R

2029P-C1RT

Содержание SuperServer 2029P-C1R

Страница 1: ...USER S MANUAL Revision 1 0a SuperServer 2029P C1R 2029P C1RT...

Страница 2: ...operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cau...

Страница 3: ...ties and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities ftp ftp supermicro com Product safety info http www supermic...

Страница 4: ...iew 17 2 2 Preparing for Setup 17 Choosing a Setup Location 17 Rack Precautions 17 Server Precautions 18 Rack Mounting Considerations 18 Ambient Operating Temperature 18 Airflow 18 Mechanical Loading...

Страница 5: ...paring the CPU Socket for Installation 35 Installing the Processor Heatsink Module PHM 36 Connecting an HFI Carrier Card 37 Removing the Processor Heatsink Module from the Motherboard 38 Memory 39 Mem...

Страница 6: ...lling the Windows OS for a RAID System 67 Installing Windows to a Non RAID System 67 5 2 Driver Installation 68 5 3 SuperDoctor 5 69 5 4 IPMI 70 Chapter 6 BIOS 6 1 Introduction 71 Starting BIOS Setup...

Страница 7: ...Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technic...

Страница 8: ...twork ports The 2029P C1R model supports 1 Gbps The 2029P C1RT model supports 10 Gbps In addition to the motherboard and chassis several included parts are listed below Main Parts List Description Par...

Страница 9: ...SAS3 12Gbps drives and eight SATA3 6Gbps drives can be hot swap if supported by the operating system Optional Up to two fixed internal drives SATA or NVMe Input Output Network Two LAN ports 2029P C1R...

Страница 10: ...hen the system is operating 4 Drive Activity LED Indicates activity on the hard drive when flashing 5 NIC LED Indicates network activity on the LAN when flashing 6 NIC LED Indicates network activity o...

Страница 11: ...0 25Hz Power failure check for a non operational power supply Solid blue Local UID has been activated Use this function to locate the server in a rack mount environment Blinking blue Remote UID is on...

Страница 12: ...n 1 Power Supplies Redundant power modules 2 I O ports Described in this manual Section 4 3 3 PCI Slots Five low profile PCIe slots two others are not usable Figure 1 3 Chassis Rear View Rear Features...

Страница 13: ...JPME1 JD1 M 2 PCH A C JPG1 JNVI2C2 S SATA5 S SATA4 3 0 USB 7 8 3 0 USB 6 USB 2 3 COM2 CPU1 SLOT1 PCI E 3 0 X8 CPU1 SLOT2 PCI E 3 0 X16 CPU1 SLOT3 PCI E 3 0 X8 CPU2 SLOT4 PCI E 3 0 X16 CPU2 SLOT5 PCI E...

Страница 14: ...PMB1 4 pin BMC External I2 C header for an IPMI supported card JL1 Chassis Intrusion header JM2_1 PCIe M 2 slot JNVI2 C1 JNVI2 C2 NVMe I2 C headers used for PCIe hot plug SMBus clock and data connecti...

Страница 15: ...USB4 5 Back panel USB 3 0 Ports USB6 Type A USB 3 0 Header USB7 8 Front Accessible USB 3 0 Header VGA VGA Port LED Description State Status LE1 UID Unit Identifier LED Solid Blue Unit identified LE2 O...

Страница 16: ...PCI E X8 PCI E X16 G3 LANE REVERSE DMI3 PCI E X16 PCI E X8 G3 PCI E X8 G3 2 I M D 3 I M D DDR4 DDR4 PCI E X8 LAN 10G 1G SLOT 4 SLOT 5 PCI E X16 PCI E X16 SLOT 6 PCI E X16 PCI E X16 G3 PCI E X16 G3 PCI...

Страница 17: ...ease read this section in its entirety before you begin the installation Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where hea...

Страница 18: ...ver from power surges and voltage spikes and to keep your system operating in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always k...

Страница 19: ...onnections other than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit in a rack you must take special precaut...

Страница 20: ...the chassis and so marked Each rail consists of two sections a front section which secures to the front post of the rack and a rear section which adjusts in length and secures to the rear post of the...

Страница 21: ...rver from coming completely out of the rack when when the chassis is pulled out for servicing To mount the rail onto the chassis first release the inner rail from the outer rails 1 Pull the inner rail...

Страница 22: ...gning the hooks on the side of the chassis with the holes in the inner rail 3 Slide the inner rail forward toward the front of the chassis and under the hooks until the quick release bracket snaps int...

Страница 23: ...he locking tab at the rear end of the middle rail 2 Push the middle rail back into the outer rail 3 Hang the hooks on the front of the outer rail onto the square holes on the front of the rack If desi...

Страница 24: ...Align the rear of the chassis rails with the middle rails and then push evenly on both sides of the chassis until it clicks into the fully extended position 3 Depress the locking tabs on both sides of...

Страница 25: ...ad the heavy chassis from the rack without assistance Be sure to have sufficient assistance supporting the chassis when removing it from the rack Use a lift 1 Pull the chassis forward out the front of...

Страница 26: ...nt of most components require that power first be removed from the system Please follow the procedures given in each section 3 1 Removing Power Before performing some setup or maintenance tasks use th...

Страница 27: ...r Removing the Chassis Cover 1 Remove the screw on each side of the chassis 2 Depress the release buttons and slide the cover back and off Caution Except for short periods of time do not operate the s...

Страница 28: ...ould be assembled together first to form the Processor Heatsink Module PHM and then install the entire PHM into the CPU socket When receiving a motherboard without a processor pre installed make sure...

Страница 29: ...ssembly contains 1 the Intel SKX F CPU 2 the narrow processor clip 3 the dust cover and 4 the CPU socket 3 Dust Cover 4 CPU Socket 1 SKX F CPU Note Be sure to cover the CPU socket with the dust cover...

Страница 30: ...ink design for each CPU The SNK P0068PSC model is used for CPU1 the CPU closer to the mid chassis fans Note For CPU1 the SNK P0068PSC heatsink must be installed with the side with short fins facing th...

Страница 31: ...Processor Heatsink Module PHM The Processor Heatsink Module PHM contains 1 a heatsink 2 a narrow processor clip and 3 the SKX F processor 1 Heatsink 2 Narrow processor clip 3 SKX F Processor Bottom V...

Страница 32: ...per position on the processor clip and carefully insert the CPU into the processor clip Slide notch B of the CPU into tab B of the processor clip and slide notch C of the CPU into tab C of the process...

Страница 33: ...p CPU Upside Down w CPU LGA Lands up CPU Heatsink Package Upside Down B B Align Notch B of the CPU and Notch B of the Processor Clip Processor Package Assembly for the F Model Processors with CPU moun...

Страница 34: ...set of mounting clips and a hole at the diagonal corner of the of the processor package assembly b in the drawing 4 With the underside of heatsink and the underside of the processor package assembly...

Страница 35: ...Do not touch the socket pins Dust Cover CPU Socket Removing the Socket Dust Cover Heatsink Upside Down C D d c a b A B On Locations of C D the notches snap onto the heat sink s mounting holes On Loca...

Страница 36: ...diagonal corners of the PHM onto the two guide posts on the socket bracket and carefully drop the PHM onto the socket 4 Use a T30 Torx bit screwdriver to install four screws into the mounting holes o...

Страница 37: ...otherboard 3 Connect the HFI connector on the HFI sideband cable to the JHFI1 header 4 Connect the other end of the HFI cable to the connector marked A on the HFI card as shown below 5 Connect the the...

Страница 38: ...iver loosen and remove the screws on the PHM from the socket starting with the screw marked 4 in the sequence of 4 3 2 1 2 Pull up the PHM while releasing the small snap tabs on two corners of the soc...

Страница 39: ...channel will result in reduced memory performance Check the Supermicro website for possible updates to memory support DIMM Module Population Configuration For optimal memory performance follow the spe...

Страница 40: ...4RX4 3DS LRDIMM Raw Cards A B 8RX4 General Population Requirements DIMM Mixing Rules All DIMMs must be DDR4 X4 and X8 DIMMs can be mixed in the same channel Mixing of LRDIMMs and RDIMMs is not allowed...

Страница 41: ...lated first Caution Exercise caution when installing or removing memory modules to prevent damage to the DIMMs or slots Installing Memory 1 Remove power from the system as described in Section 3 1 2 S...

Страница 42: ...supports PCIe 3 0 X4 32 Gb s SSD cards in the 2280 and 22110 form factors A Holder B Holder Mount C Card Holder Mount Turn 90 degrees to lock Locked position with M 2 card Locked position Locked posit...

Страница 43: ...Replacing the Battery Begin by removing power from the system as described in section 3 1 1 Push aside the small clamp that covers the edge of the battery When the battery is released lift it out of...

Страница 44: ...Drive Carrier Indicators Each drive carrier has two LED indicators an activity indicator and a status indicator In RAID configurations the status indicator lights to indicate the status of the drive...

Страница 45: ...tton on the drive carrier This extends the drive carrier handle 2 Use the handle to pull the carrier out of the chassis Figure 3 6 3 Remove the dummy drive from the carrier Figure 3 7 Caution Except f...

Страница 46: ...he drive align with those in the carrier 2 Secure the hard drive into the carrier with the screws Figure 3 9 Installing the Hard Drive 3 Insert the drive and carrier into its bay vertically keeping th...

Страница 47: ...can be removed by pulling out the drive tray beneath the DVD drive bay then pulling the mini bezel forward 3 Insert the new drive unit in the slot until the tab locks in place 4 Connect the data and p...

Страница 48: ...Supermicro Web site Installing a Peripheral Device 1 Power down the system and remove the cover 2 Locate the locking tab at the rear left hand side when viewed from the front of the tray Push the tab...

Страница 49: ...he device unit out the front of the chassis 3 For a 3 5 drive place the drive in the drive tray and secure the drive to the tray with four screws from the bottom For one or two 2 5 drives install the...

Страница 50: ...by a SAS3 controller card Installing an Expansion Card 1 Power down the system and remove the cover 2 In the rear of the chassis remove the blank PCI shield that covers the chassis slot 3 Slide the e...

Страница 51: ...If not remove the chassis cover while the power is on and examine the fans to determine which one has failed 2 Remove the failed fan s power cable from the backplane 3 Lift the fan housing up and out...

Страница 52: ...sure no wires or foreign objects obstruct airflow through the chassis Pull all excess cabling out of the airflow path or use shorter cables Installing the Air Shrouds Air shrouds concentrate airflow...

Страница 53: ...100 120v or 180 240v An amber light will be illuminated on the power supply when the power is off An illuminated green light indicates that the power supply is operating Replacing the Power Supply 1 U...

Страница 54: ...ing is included with the power supply One 24 pin Primary ATX Power JPWR3 Two 8 pin Processor Power JPWR1 JPWR2 Main ATX Power Connector The primary power connector JPWR3 meets the ATX SSI EPS 24 pin s...

Страница 55: ...4 PWM Control I SATA 3 0 and S SATA 3 0 Ports SATA is supported on the X11DPi N T motherboard by three iPass connectors and two SATA powered ports The powered ports S SATA4 S SATA5 are yellow connecto...

Страница 56: ...sed in creating optional advanced NVMe RAID configurations SGPIO Header The T SGPIO3 Serial General Purpose Input Output header is used to communicate with the enclosure management chip on the backpla...

Страница 57: ...k 4 No Connection Chassis Intrusion A chassis Intrusion header is located at JL1 on the motherboard Attach the appropriate cable from the chassis to alert you when the chassis is opened Chassis Intrus...

Страница 58: ...a Supermicro complete system with a proprietary NVMe add on card and cable installed NVMe SMBus Header Pin Definitions Pin Definition 1 Data 2 Ground 3 Clock 4 VICCIO NVMe Connectors NVMe I2 C headers...

Страница 59: ...ata signal Ground Key Power On LED Control signal HDD LED Activity signal NIC1 LED Ground NIC2 LED Ground OH Fan Fail LED Ground Power Fail LED Ground Ground Ground 2 1 20 19 Power Button Pin Definiti...

Страница 60: ...on 7 Blue LED 8 OH Fan Fail LED LAN1 LAN2 LED Pin Definitions JF1 Pin Definition 9 NIC2 Activity LED 10 NIC2 Link LED 11 NIC1 Activity LED 12 NIC1 Link LED NIC1 NIC2 LAN1 LAN2 The NIC Network Interfac...

Страница 61: ...s The data cables in the system have been carefully routed to maintain airflow efficiency If you disconnect any of these cables take care to re route them as they were originally when reconnecting the...

Страница 62: ...he onboard headers can be used to provide front side USB access with a cable not included IPMI Port A LAN port is a dedicated connection for IPMI Ethernet Ports Two Ethernet ports LAN1 LAN2 X11DPi NT...

Страница 63: ...ns Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the conten...

Страница 64: ...al power operation and management In the single operation mode online upgrade will be available via Recovery mode See the table below for jumper settings Manufacturer Mode Jumper Settings Jumper Setti...

Страница 65: ...e of the LAN port may be green amber or off indicating the speed of the connection LAN Link Indicator LED Settings LED Color Definition Off No Connection 10 or 100 Mbps Green 10 Gbps 2029P C1RT only A...

Страница 66: ...en this LED is on the system is on Be sure to turn off the system and unplug the power cord before removing or installing components Onboard Power LED Indicator LED Color Definition Off System Off pow...

Страница 67: ...the system Note for older legacy OS s please use a method to slipstream the drivers 3 Select the partition on the drive in which to install Windows 4 Browse the USB folder for the proper driver files...

Страница 68: ...ear Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard here where you may download individual drivers and utilities to you...

Страница 69: ...Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server you can r...

Страница 70: ...gent Platform Management Interface IPMI IPMI is used to provide remote access monitoring and management There are several BIOS settings that are related to IPMI For general documentation and informati...

Страница 71: ...lected it is highlighted in white Settings printed in Bold are the default values In the left frame a indicates a submenu Highlighting such an item and pressing the Enter key opens the list of setting...

Страница 72: ...using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY format The time is entered in HH MM SS format Note The time is in the 24 hour forma...

Страница 73: ...Quiet Boot Use this feature to select the screen between displaying POST messages or the OEM logo at bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead...

Страница 74: ...and Postponed Re try Boot When EFI Expansible Firmware Interface Boot is selected the system BIOS will automatically reboot the system from an EFI boot device after an initial boot failure Select Leg...

Страница 75: ...enable Execute Disable Bit support which will allow the processor to designate areas in the system memory where an application code can execute and where it cannot thus preventing a worm or a virus fr...

Страница 76: ...is set to Enable the DCU Data Cache Unit streamer prefetcher will prefetch data streams from the cache memory to the DCU Data Cache Unit to speed up data accessing and processing for CPU performance...

Страница 77: ...ter than the frequency specified by the manufacturer The options are Disable and Enable Hardware PM Power Management State Control Hardware P States If this feature is set to Disable hardware will cho...

Страница 78: ...ons may cause the system to malfunc tion North Bridge This feature allows the user to configure the settings for the Intel North Bridge UPI Ultra Path Interconnect Configuration This section displays...

Страница 79: ...rce POR Select POR to enforce POR restrictions for DDR4 memory frequency and voltage programming The options are POR and Disable Memory Frequency Use this feature to set the maximum memory frequency f...

Страница 80: ...ory rank sparing to optimize memory performance The options are Enable and Disable Note This item will not be available when memory mirror mode is enabled Memory Correctable Error Threshold Use this i...

Страница 81: ...options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 and Auto IOU1 IIO PCIe Br2 This item configures the PCI E Bifuraction setting for a PCI E port specified by the user The options are x4x4x4x4 x4x4x8 x8x4x4...

Страница 82: ...L requests that will allow the hints to be sent to help facilitate and optimize the processing of certain transactions in the system memory The options are Enable and Disable Relaxed Ordering Select E...

Страница 83: ...nable and Disable Coherency Support Non Isoch Select Enable for the Non Iscoh VT d engine to pass through DMA Direct Memory Access to enhance system performance The options are Enable and Disable Inte...

Страница 84: ...bled and Disabled Port 60 64 Emulation Select Enabled for I O port 60h 64h emulation support which in turn will provide complete legacy USB keyboard support for the operating systems that do not suppo...

Страница 85: ...oller should be used for system boot The options are None SATA Controller sSATA Controller and Both Aggressive Link Power Management When this item is set to Enabled the SATA AHCI controller manages t...

Страница 86: ...sword in the OS The options are Enable and Disable SATA sSATA RAID Boot Select Available when the item Configure SATA as is set to RAID This feature allows the user to decide which controller should b...

Страница 87: ...d Disabled SR IOV Support Available if the system supports Single Root Virtualization Select Enabled for Single Root IO Virtualization support The options are Enabled and Disabled MMIOHBase Use this i...

Страница 88: ...PCI E x16 OPROM Select EFI to allow the user to boot the computer using an EFI Expansible Firmware Interface device installed on the PCI E slot specified by the user Select Legacy to allow the user to...

Страница 89: ...and Disabled PXE Boot Wait Time Use this feature to select the wait time to press the ESC key to abort the PXE boot The default is 0 Media Detect Time Use this feature to select the wait time in secon...

Страница 90: ...2F8h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 and IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Serial Port 2 Attribute Select SOL to use COM Port 2...

Страница 91: ...our data bits The options are None Even Odd Mark and Space Stop Bits A stop bit indicates the end of a serial data packet Select 1 Stop Bit for standard serial data communication Select 2 Stop Bits if...

Страница 92: ...w the host computer will exchange data with the client computer which is the remote computer used by the user Terminal Type Use this feature to select the target terminal emulation type for Console Re...

Страница 93: ...ct Enabled to enable VT UTF8 Combination Key support for ANSI VT100 terminals The options are Enabled and Disabled Recorder Mode Select Enabled to capture the data displayed on a terminal and send it...

Страница 94: ...ection and COM2 SOL Console Redirection Terminal Type Use this feature to select the target terminal emulation type for Console Redirection Select VT100 to use the ASCII character set Select VT100 to...

Страница 95: ...ding smooth playback and reducing the dependency on other timestamp calculation devices such as an x86 RDTSC Instruction embedded in the CPU The High Performance Event Timer is used to replace the 825...

Страница 96: ...to be used for initial system boot This early boot code is shipped with the platform and is included in the list of public keys During system boot the platform firmware uses this trusted public key t...

Страница 97: ...led PH Platform Hierarchy Randomization for TPM Version 2 0 and above Select Enabled for Platform Hierarchy Randomization support which is used only during the platform developmental stage This featur...

Страница 98: ...Enabled and Disabled Erasing Settings Erase Event Log Select Enabled to erase all error events in the SMBIOS System Management BIOS log before an event logging is initialized at bootup The options ar...

Страница 99: ...te Please reboot the system for the changes to take effect Customer Options Log OEM Codes Select Enabled to log the EFI Status codes as OEM codes if these codes have not been converted to Legacy The o...

Страница 100: ...ling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Enabled and Disabled Erasing Settings Erase SEL Select Yes On next reset to erase all system...

Страница 101: ...us This item displays the IPMI Network Link status The default setting is Shared LAN Current Configuration Address Source This item displays the source of the current IPMI LAN address The default sett...

Страница 102: ...you will need to know the IP address of this computer and enter it to the system manually in the field If DHCP is selected AMI BIOS will search for a DHCP Dynamic Host Configuration Protocol server at...

Страница 103: ...ot will be activated when a Platform Key PK is entered A Platform Key is a security key used to manage the security settings of the platform firmware used in your system The options are Enabled and Di...

Страница 104: ...ures This feature allows the user to enter and configure a set of values to be used as Authorized Signatures for the system This set of values also indicate the size the keys numbers and the key sourc...

Страница 105: ...able device from which the system will boot Press Enter on each entry from top to bottom to select devices When the item above Boot Mode Select is set to Dual default the following items will be displ...

Страница 106: ...select a boot device to delete from the boot priority list Delete Boot Option Use this feature to remove an EFI boot option from the boot priority list Add New Driver Option Use this feature to selec...

Страница 107: ...priority list Hard Disk Drive BBS Priorities Boot Option 1 5 Network Drive BBS Priorities Boot Option 1 USB Key Drive BBS Priorities Boot Option 1 UEFI Hard Disk Drive BBS Priorities Boot Option 1 UE...

Страница 108: ...Save Changes and Reset When you have completed the system configuration changes select this option to leave the BIOS setup utility and reboot the computer for the new system configuration parameters...

Страница 109: ...m the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults from the Exit menu and...

Страница 110: ...occurs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list on the fo...

Страница 111: ...com support manuals AMI BIOS POST Codes User s Guide When BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot process a diagnost...

Страница 112: ...or assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis Thes...

Страница 113: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...

Страница 114: ...ken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan...

Страница 115: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...

Страница 116: ...tes del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l inst...

Страница 117: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...

Страница 118: ...abels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Wa...

Страница 119: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...

Страница 120: ...a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s...

Страница 121: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...

Страница 122: ...aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All co...

Страница 123: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...

Страница 124: ...dvertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques c...

Страница 125: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...

Страница 126: ...ale elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accord...

Страница 127: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...

Страница 128: ...estornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient t...

Страница 129: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSE Supermicro Supermicro UL CSA UL CSA Supermicro U...

Страница 130: ...le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto ut...

Страница 131: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...

Страница 132: ...wo fixed SATA or NVMe drives PCI Expansion Slots Four PCI Express 3 0 x16 slots One PCI Express 3 0 x8 slots Motherboard X11DPi N T proprietary form factor Dimensions 10 47 L x 16 97 W 265 94 mm x 431...

Страница 133: ...0 3 2 3 3 CISPR 22 Class A Electromagnetic Immunity EN 55024 CISPR 24 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety CSA EN IEC UL 60950 1 Compliant...

Страница 134: ...s of a recovery BIOS block and a main BIOS block a main BIOS image The recovery block contains critical BIOS codes including memory detection and recovery codes for the user to flash a healthy BIOS im...

Страница 135: ...a USB attached device follow the instructions below 1 Using a different machine copy the Super ROM binary image file into the Root directory of a USB device or a writable CD DVD Notes 1 If you cannot...

Страница 136: ...if you want to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 4 When the screen as shown above displays use the arrow keys to select the item Proceed w...

Страница 137: ...to enter the BIOS Setup utility From the top of the tool bar select Boot to enter the submenu From the submenu list select Boot Option 1 as shown below Then set Boot Option 1 to UEFI AP UEFI Built in...

Страница 138: ...terrupt this process until the BIOS flashing is complete 9 The screen above indicates that the BIOS update process is complete When you see the screen above unplug the AC power cable from the power su...

Отзывы: