Figure 3-22. Removing/Replacing a Power Supply
Power Supply
The system includes dual hot-plug 2000 Watt power modules. They automatically sense the
input voltage between 100v to 240v, and operate at that voltage. Note that different input
voltages will result in different maximum power output levels.
In the event of a power supply failure, the remaining power supply will automatically take
over.* The failed power module can then be replaced without powering-down the system with
the same model. Replacement modules can be ordered directly from Supermicro.
An amber light on the power supply is illuminated when the power is switched off. A green
light indicates that the power supply is operating.
Replacing the Power Supply
1. Push the release tab on the front of the failed power supply.
2. Grasp the handle of the power supply and pull it out of the power supply bay.
3. Push the new power supply module into the power bay until it clicks into the locked
position.
2
1