Chapter 5: Advanced Serverboard Setup
5-3
Socket key
CPU installed in socket
PnP cap released
from load plate
Use your thumb and index fi nger
3.
to hold the CPU at opposite sides.
Align pin1 of the CPU (the corner
4.
marked with a triangle) with the
notched corner of the CPU socket.
Find the corner of the CPU that
5.
has a semi-circle cutout below a
gold dot (CPU key). This corner
should be aligned with the cutout
on the socket (socket key).
Once aligned, carefully lower the
6.
CPU straight down into the socket.
Do not drop the CPU on the sock-
et, do not move the it horizontally
or vertically and do not rub the it
against any surface or any of the
contacts, which may damage the
CPU and/or its contacts.
Inspect the four corners of the
7.
CPU to make sure that it is prop-
erly installed.
Use your thumb to gently push the
8.
load lever down until it snaps into
the retention clasp.
If the CPU is properly installed
9.
into the socket, the PnP cap will
be automatically released from the
load plate when the lever locks.
Remove the cap. Repeat steps to
install a second CPU if desired.
Warning!
Keep the plastic PnP
cap. The serverboard must be
shipped with the PnP cap prop-
erly installed to protect the CPU
socket. Shipment without the PnP
cap properly installed will void the
warranty.
CPU key
CPU pin 1
Notched corner
Gold dot
Load lever
Содержание SUPERSERVER 1025W-U
Страница 1: ...SUPERSERVER 1025W U SUPERSERVER 1025W UR SUPER USER S MANUAL 1 0a...
Страница 5: ...v Preface Notes...
Страница 14: ...SUPERSERVER 1025W U 1025W UR Manual 1 6 Notes...
Страница 21: ...Chapter 2 Server Installation 2 7 Figure 2 4 Installing the Outer Rails to the Rack 2 3 3...
Страница 26: ...2 12 SUPERSERVER 1025W U 1025W UR Manual Notes...
Страница 70: ...6 10 SUPERSERVER 1025W U 1025W UR Manual Notes...
Страница 102: ...A 6 SUPERSERVER 1025W U 1025W UR User s Manual Notes...
Страница 108: ...B 6 SUPERSERVER 1025W U 1025W UR User s Manual Notes...
Страница 112: ...C 4 SUPERSERVER 1025W U 1025W UR User s Manual Notes...