5-7 PCI Expansion Cards
Two riser cards are used to support add-on cards to the system. The chassis can
accommodate one standard size (full height full length) and one low-profi le PCI
expansion card (up to 5.5" long) in addition to a UIO card. When viewed from the
chassis front, the standard size card installs to the left and the low-profi le card
installs to the right side.
PCI cards are installed into riser cards that have been pre-installed to the system.
See confi guration list below.
Installing a PCI Expansion Card
Confi rm that you have the correct riser card for your chassis model and the
1.
add-on card includes a standard bracket.
Remove the chassis cover.
2.
Install the riser card by sliding card into the appropriate riser card in the moth-
3.
erboard. For more information, see the riser card installation instructions.
Choose the PCI slot shield in which to place the add-on card.
4.
In that slot, open the PCI slot shield lever and slide the shield sideways.
5.
From inside the chassis, remove the PCI slot shield.
6.
Slide the add-on card into the riser card and attach the add-on card bracket
7.
in place of the PCI slot shield.
Secure the add-on card by closing the PCI slot shield lever.
8.
Connect cables to the add-on card as necessary.
9.
PCI Slot/Card Confi gurations
Right Side Riser Card
Expansion card supported
RSC-R1UU-E8
1x
low-profi le PCI-E x8 card
Содержание SUPERSERVER 1015B-M3
Страница 1: ...SUPER USER S MANUAL Revision 1 0 SUPERSERVER 1015B M3...
Страница 5: ...v Preface Notes...
Страница 10: ...Notes SUPERSERVER 1015B M3 User s Manual x...
Страница 16: ...1 6 SUPERSERVER 1015B M3 User s Manual Notes...
Страница 23: ...Chapter 2 Server Installation 2 7 Figure 2 4 Installing the Outer Rails to the Rack 2 3 3...
Страница 28: ...2 12 SUPERSERVER 1015B M3 Manual Notes...
Страница 94: ...A 2 SUPERSERVER 1015B M3 User s Manual Notes...