background image

SBI-7127R-SH Blade Module User’s Manual

2-6

¡Advertencia! 

El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico 
quitado de los módulos de fuente de alimentación antes de tener acceso el interior del 
chasis para instalar o para quitar componentes de sistema.

Attention

Le système doit être débranché de toutes les sources de puissance ainsi que de son 
cordon d'alimentation secteur avant d'accéder à l'intérieur du chassis pour installer ou 
enlever des composants de systéme.

경고 !

시스템에 부품들을 장착하거나 제거하기 위해서는 섀시 내부에 접근하기 전에 반드시 
전원 공급장치로부터 연결되어있는 모든 전원과 전기코드를 분리해주어야 합니다 .

Waarschuwing

Voordat u toegang neemt tot het binnenwerk van de behuizing voor het installeren of 
verwijderen van systeem onderdelen, dient u alle spanningsbronnen en alle 
stroomkabels  aangesloten op de voeding(en) van de behuizing te verwijderen.

Equipment Installation

Warning!

Only trained and qualified personnel should be allowed to install, replace, or 
service this equipment.

機器の設置

トレーニングを受け認定された人だけがこの装置の設置、交換、またはサービスを許
可されています。

警告

只有经过培训且具有资格的人员才能进行此设备的安装、更换和维修。

警告

只有經過受訓且具資格人員才可安裝、更換與維修此設備。

יילמשח קותינ ינפמ הרהזא

 

 

!הרהזא

 

 למשחה תורוקמ לכמ תכרעמה תא קתנל שי

 ריסהל שיו

 קפסהמ ילמשחה לבכ תא

נקתה ךרוצל זראמה לש ימינפה קלחל השיג ינפל

ת

 

רסה וא

ת

 

.םיביכר

 

ﻞﺼﻓ ﺐﺠﻳ

 

ﻡﺎﻈﻨﻟﺍ

 

 ﻊﻴﻤﺟ ﻦﻣ

ﺭﺩﺎﺼﻣ

 

ﺔﻗﺎﻄﻟﺍ

 

ﺔﻟﺍﺯﺇﻭ

 

ءﺎﺑﺮﻬﻜﻟﺍ ﻚﻠﺳ

 

ﻦﻣ

 

ﺓﺪﺣﻭ

 

ﺩﺍﺪﻣﺍ

 

ﺔﻗﺎﻄﻟﺍ

 

ﻞﺒﻗ

 

 

ﻰﻟﺇ ﻝﻮﺻﻮﻟﺍ

 

ﺔﻴﻠﺧﺍﺪﻟﺍ ﻖﻁﺎﻨﻤﻟﺍ

 ﻟ

ﻞﻜﻴﻬﻠ

 

ﺔﻟﺍﺯﺇ ﻭﺃ ﺖﻴﺒﺜﺘﻟ

 

ﺕﺎﻧﻮﻜﻣ

 

ﺯﺎﻬﺠﻟﺍ

 

Содержание SBI-7127R-SH

Страница 1: ...SBI 7127R SH Blade Module User s Manual Revison 1 0...

Страница 2: ...for the resolution of any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to...

Страница 3: ...eneral overview of safety precautions that should be followed when installing and servicing SBI 7127R SH blade module Chapter 3 Setup and Installation Refer to this chapter for details on installing t...

Страница 4: ...SBI 7127R SH Blade Module User s Manual 0 iv Notes...

Страница 5: ...4 Power Disconnection Warning 2 5 Equipment Installation 2 6 Restricted Area 2 7 Battery Handling 2 9 Redundant Power Supplies 2 10 Backplane Voltage 2 11 Comply with Local and National Electrical Cod...

Страница 6: ...ion 3 16 3 9 Management Software 3 17 3 10 Configuring and Setting up RAID 3 17 Chapter 4 Blade Module Features 4 1 4 1 Control Panel 4 2 Power Button 4 3 KVM Button 4 3 LED Indicators 4 3 KVM Connect...

Страница 7: ...1 vii 5 8 Boot 5 17 5 9 Security 5 17 5 10 Save Exit 5 18 Appendix A AMI UEFI BIOS POST Codes A 1 A 1 Checkpoint Ranges A 1 A 2 Standard Checkpoints A 2 A 3 OEM Reserved Checkpoint Ranges A 9...

Страница 8: ...SBI 7127R SH Blade Module User s Manual 1 viii Notes...

Страница 9: ...necessary drivers utilities and the user s manual for your server SMCI product manuals http www supermicro com support manuals Product drivers and utilities ftp ftp supermicro com Product safety infor...

Страница 10: ...66 800 MHz speed 32GB 16GB 8GB 4GB 2GB and 1GB size SDRAM memory Memory is interleaved which requires modules of the same size and speed to be installed in groups of two or three Please refer to the S...

Страница 11: ...r using a single disk RAID1 Data Mirroring an identical data image from one drive is copied to another drive The second drive must be the same size or larger than the first drive Further infomation on...

Страница 12: ...SBI 7127R SH Blade Module User s Manual 1 4 Figure 1 1 Full Rack of Blade Enclosures and Blade Servers...

Страница 13: ...ope Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicr...

Страница 14: ...SBI 7127R SH Blade Module User s Manual 1 6 Notes...

Страница 15: ...ed technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis These warnings may also be fou...

Страница 16: ...considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar...

Страница 17: ...m ongelukken te voorkomen Gebruik de nummers aan het eind van elke waarschuwing om deze te herleiden naar de desbetreffende locatie BEWAAR DEZE INSTRUCTIES Installation Instructions Warning Read the i...

Страница 18: ...angewiesen dass im Geb ude ein Kurzschluss bzw berstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo utili...

Страница 19: ...Warning Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing the chassis interior to install or remove system c...

Страница 20: ...les sources de puissance ainsi que de son cordon d alimentation secteur avant d acc der l int rieur du chassis pour installer ou enlever des composants de syst me Waarschuwing Voordat u toegang neemt...

Страница 21: ...nd de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Waarschuwing Deze apparatuur mag alleen worden ge nstalleerd vervangen of hers...

Страница 22: ...o a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc...

Страница 23: ...ichen oder vom Hersteller empfohlenen Batterietyp Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers Attention Danger d explosion si la pile n est pas remplac e correctement Ne...

Страница 24: ...nnection All connections must be removed to de energize the unit Warnung Dieses Ger t kann mehr als eine Stromzufuhr haben Um sicherzustellen dass der Einheit kein trom zugef hrt wird m ssen alle Verb...

Страница 25: ...ckplane when the system is operating Use caution when servicing Warnung Wenn das System in Betrieb ist treten auf der R ckwandplatine gef hrliche Spannungen oder Energien auf Vorsicht bei der Wartung...

Страница 26: ...Comply with Local and National Electrical Codes Warning Installation of the equipment must comply with local and national electrical codes Warnung Die Installation der Ger te muss den Sicherheitsstand...

Страница 27: ...according to all national laws and regulations Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Advertencia Al deshacerse por completo de este pro...

Страница 28: ...drehen sich u U noch wenn die L fterbaugruppe aus dem Chassis genommen wird Halten Sie Finger Schraubendreher und andere Gegenst nde von den ffnungen des L ftergeh uses entfernt Advertencia Los ventil...

Страница 29: ...wer Cable and AC Adapter Warning When installing the product use the provided or designated connection cables power cables and AC adaptors Using any other cables and adaptors could cause a malfunction...

Страница 30: ...tilizaci n de otros cables y adaptadores podr a ocasionar un mal funcionamiento o un incendio Aparatos El ctricos y la Ley de Seguridad del Material proh be el uso de UL o CSA cables certificados que...

Страница 31: ...de meegeleverde of aangewezen kabels stroomkabels en adapters Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand Elektrisch apparaat en veiligheidsinformatiebladen wet...

Страница 32: ...SBI 7127R SH Blade Module User s Manual 2 18 Notes...

Страница 33: ...off independently from the rest of the blades installed in the same enclosure A blade unit may be powered up in two ways Press the power button on the blade unit Use IPMIView or the web browser based...

Страница 34: ...nclosure above 2 Depress the two buttons on the cover while pushing the cover toward the rear of the blade unit When it stops lift the cover off the blade unit 3 To replace the cover fit the six groov...

Страница 35: ...3 3 Chapter 3 Setup and Installation Figure 3 1 Inserting a Blade into the Enclosure Figure 3 2 Locking the Blade into Position...

Страница 36: ...comes into contact with the thermal grease on its underside 5 Raise the lever of the processor socket up until the processor is released from the socket then lift the silver cover plate and remove th...

Страница 37: ...ess the second load lever labeled Close 1st to release the load plate that covers the CPU socket from its locking position Figure 3 4 Figure 3 3 Open First Load Lever Figure 3 4 Close First Load Lever...

Страница 38: ...he load plate Lift the load plate to open it completely Figure 3 5 4 Using your thumb and the index finger remove the WARNING plastic cap from the socket Figure 3 6 Figure 3 5 Opening the Load Plate F...

Страница 39: ...y pins of the socket to avoid damaging the CPU or the socket Caution You can only install the CPU inside the socket in one direction Make sure that the CPU is properly inserted into the CPU socket bef...

Страница 40: ...ver labeled Open 1st second Figure 3 11 Use your thumb to gently push the load levers down to the lever locks Figure 3 9 Closing the Load Plate Figure 3 10 Locking the Close First Lever Figure 3 11 Lo...

Страница 41: ...of the same size and speed and from the same Super Micro authorized manufacturer due to compatibility issues See details below on supported memory and our web site www supermicro com products superbla...

Страница 42: ...ght Memory Slots for Interleaved Operation of DIMMs CPU1 CPU2 Channel A Channel B Channel C Channel D Channel E Channel F Channel G Channel H A1 A2 B1 B2 C1 C2 D1 D2 E1 E2 F1 F2 G1 G2 H1 H2 4 X X X X...

Страница 43: ...ots A1 and A2 Pay attention to the notch along the bottom of the module to prevent inserting the DIMM incorrectly see Figure 3 14 5 Gently press down on the DIMM until it snaps into place in the slot...

Страница 44: ...carrier out To Install a hard drive use the following procedure Installing a Hard Drive 1 Remove a blank drive carrier from the blade see removal procedure above 2 Insert a drive into the carrier with...

Страница 45: ...ows the add on card to be properly installed parallel to the blade module s mainboard There is also cover shield that you must attach to the add on card in order to maintain proper air flow to the bla...

Страница 46: ...add on card pushing down with your thumbs evenly on both sides of the card Figure 3 17 Figure 3 17 Attaching Add On Card to Riser Card 4 Install the riser card and add on card combination into the bl...

Страница 47: ...cable to provide multiple USB ports 2 Connect the external CD ROM drive a USB keyboard and a mouse to the USB hub You will also need to connect a monitor to the video connector on the SUV cable Turn...

Страница 48: ...h either the IPMIview Java based client utility IPMItool or the Web based Management Utility With this method the OS is installed from an ISO image that resides on another system blade Refer to the ma...

Страница 49: ...tor with a comprehensive set of functions and monitored data to keep tabs on the system and perform management activities Refer to the manuals on your SuperBlade CD ROM for further details on the vari...

Страница 50: ...SBI 7127R SH Blade Module User s Manual 3 18...

Страница 51: ...ure Description Processors Supports single or dual 2011 pin Socket R LGA 2011 E5 2600 series processors Memory Supports up to 512 GB of RDIMM and 128 GB of UDIMM DDR3 1600 1333 1066 800 MHz speed 32GB...

Страница 52: ...s blade module on and off 2 KVM Button N A Initiates KVM function 3 Power LED Green Indicates power status On Orange Indicates power status Off with power cables plugged in 4 KVM UID LED Blue Indicate...

Страница 53: ...other blade disconnect the cable then reconnect it to the new blade See the Web based Management Utility User s Manual on your SuperBlade system CD ROM for further details on using the KVM function re...

Страница 54: ...ade unit is a proprietary design which is based on the Intel C602J chipset See Figure 4 4 for a block diagram of this chipset Figure 4 3 for a view of the B9DRP mainboard and Figure 4 5 for an explode...

Страница 55: ...3 16 slot DIMM Numbering on page 3 10 for details 4 2 5 SATA Hard Drive Bays two 5 Mezzanine daughter card connectors for InfiniBand or 10G cards 6 Gbx Connectors for power and logic to backplane 7 On...

Страница 56: ...ing Replacing the Blade Cover on page 3 2 for further details Short the CMOS pads with a metal object such as a small screwdriver 3 Replace the cover install the blade back into the enclosure and powe...

Страница 57: ...d View of a SBI 7127R SH Blade Module Table 4 5 Main Components of a SBI 7127R SH Blade Module Item Description 1 Blade Unit Module 2 2 5 Hard Drives two 3 Air Shroud two parts 4 DIMM slots 16 5 CPU H...

Страница 58: ...unted in drive trays The drives can be hot swapped and removed or replaced without powering down the blade unit they reside in The two drives can be used to set up a RAID array RAID 0 or 1 or JBOD The...

Страница 59: ...ttle electrical power When the blade unit is turned off a backup battery provides power to the BIOS flash chip enabling it to retain system parameters Each time the blade is powered on it is configure...

Страница 60: ...ncluded with the system 1 Copy the contents of the zip file to a bootable USB pen drive 2 Connect the KVM dongle CBL 0218L to the KVM connector at the front of the blade you will be flashing the BIOS...

Страница 61: ...ROM file name such as B8DTE142 rom for example in the command 5 3 Running Setup Note Default settings are in bold text unless otherwise noted The BIOS setup options described in this section are selec...

Страница 62: ...next section describes in detail how to navigate through the menus Items that use sub menus are indicated with the icon With the item highlighted press the ENTER key to access the submenu Menu option...

Страница 63: ...tion in the appropriate fields Then press the Enter key to save the data BIOS Information BIOS static display information including the motherboard number SMC version SMC Build Date and Total Memory i...

Страница 64: ...is sub menu Super IO Configuration SH7757 See Table 5 8 for a description of BIOS setup menu options in this sub menu Serial Port Console Redirection See Table 5 9 for a description of BIOS setup menu...

Страница 65: ...ly one thread per enabled core is enabled Active Processor Cores This setting selects the number of cores to enable in each processor package Options include All 1 2 4 and 6 Limit CPUID Maximum This s...

Страница 66: ...bled C1E Support Enabled CPU C3 Report Disabled CPU C6 Report Enabled CPU C7 Report Enabled Package C state Limit C6 Energy Performance Long Duration Power Limit Long Duration Maintained Short Duratio...

Страница 67: ...to select QPI Link Speed as being either Fast or Slow mode QPI Link Frequency Select This setting allows you to select the QPI link frequency Options include Auto 6 4 GT s 7 2 GT s or 8 0 GT s DIMM Co...

Страница 68: ...oller 1 2 Legacy USB Support This setting allows you to enable the use of Legacy USB devices If this option is set to Auto legacy USB support will be automatically enabled if a legacy USB device is in...

Страница 69: ...1024 Bytes 2048 Bytes or 4096 Bytes ASPM Support This sets the ASPM Level for your system Options include Disabled disables ASPM Auto lets BIOS auto configure or Force L0s force all links to L0s stat...

Страница 70: ...ects the serial port transmission speed which must be matched on the other side Long or noisy lines may require lower speeds Options include 9600 19200 38400 57600 and 115200 Data Bits This sets the n...

Страница 71: ...bit is 0 if the number of 1 s in the data bits is even Odd parity bit is 0 if the number of 1 s in the data bits is odd Mark parity bit is always 1 or Space parity bit is always 0 The Mark and Space...

Страница 72: ...ore bytes Bits per Second This setting selects the serial port transmission speed which must be matched on the other side Long or noisy lines may require lower speeds Options include 9600 19200 57600...

Страница 73: ...prior to any logging activation during reset Options are No Yes Next Reset and Yes Every Reset When Log is Full Use this setting to choose options for reactions to a full SMBIOS Event Log Options incl...

Страница 74: ...s setting to choose options for reactions to a full SEL Options include Do Nothing and Erase Immediately Log EFI Status Codes Use this setting to Enable or Disable logging of EFI status codes log only...

Страница 75: ...uence of priority for the boot device such as hard disk drives USB devices CD ROM drives Network drives and so on The menu options are for 1st Boot Device 2nd Boot Device and 3rd Boot device Each numb...

Страница 76: ...system will reboot and implement the changes you have made to the BIOS Setup Save Changes Highlight this item and hit ENTER to save changes done so far to any of the setup options Discard Changes High...

Страница 77: ...5 19 Chapter 5 BIOS...

Страница 78: ...SBI 7127R SH Blade Module User s Manual 5 20...

Страница 79: ...ndicate the task the system is currently executing Checkpoints are very useful in aiding software developers or technicians in debugging problems that occur during the pre boot process A 1 Checkpoint...

Страница 80: ...fter microcode loading 0x0A OEM initialization after microcode loading 0x0B Cache initialization 0x0C 0x0D Reserved for future AMI SEC error codes 0x0E Microcode not found 0x0F Microcode not loaded Ta...

Страница 81: ...itialization 0x35 CPU post memory initialization Boot Strap Processor BSP selection 0x36 CPU post memory initialization System Management Mode SMM initialization 0x37 Post Memory North Bridge initiali...

Страница 82: ...0xE1 S3 Boot Script execution 0xE2 Video repost 0xE3 OS S3 wake vector call 0xE4 0xE7 Reserved for future AMI progress codes S3 Resume Error Codes 0xE8 S3 Resume Failed 0xE9 S3 Resume PPI not Found 0x...

Страница 83: ...e Services 0x63 CPU DXE initialization is started 0x64 CPU DXE initialization CPU module specific 0x65 CPU DXE initialization CPU module specific 0x66 CPU DXE initialization CPU module specific 0x67 C...

Страница 84: ...0x79 CSM initialization 0x7A 0x7F Reserved for future AMI DXE codes 0x80 0x8F OEM DXE initialization codes 0x90 Boot Device Selection BDS phase is started 0x91 Driver connecting is started 0x92 PCI Bu...

Страница 85: ...System Reset 0xB4 USB hot plug 0xB5 PCI bus hot plug 0xB6 Clean up of NVRAM 0xB7 Configuration Reset reset of NVRAM settings 0xB8 0xBF Reserved for future AMI codes 0xC0 0xCF OEM BDS initialization c...

Страница 86: ...be met Table A 7 ACPI ASL Checkpoints Status Codes Description 0x01 System is entering S1 sleep state 0x02 System is entering S2 sleep state 0x03 System is entering S3 sleep state 0x04 System is ente...

Страница 87: ...anges Status Codes Description 0x05 OEM SEC initialization before microcode loading 0x0A OEM SEC initialization after microcode loading 0x1D 0x2A OEM pre memory initialization codes 0x3F 0x4E OEM PEI...

Страница 88: ...SBI 7127R SH Blade Module User s Manual A 10 Notes...

Страница 89: ...ected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products for use in such...

Страница 90: ...SBI 7127R SH Blade Module User s Manual 0 2 SBI 7127R SH...

Отзывы: