Supermicro L2/L3 Switches Configuration Guide
34
SMIS(config)# end
SMIS#
show ntp
[NTP] ntp is disabled
Server
Key Prefer
=============== ===== ======
200.200.200.10
100 YES
100.100.100.1
500
Key # Key
======= ====================================
Time zone offset not set
1.5.2
Enable/Disable NTP
NTP is disabled by default in Supermicro switches.
Follow the below steps to enable NTP.
Step Command
Description
Step 1
configure terminal
Enters the configuration mode.
Step 2
ntp enable
Enables NTP in the switch.
Step 3
end
Exits the configuration mode.
Step 4
show ntp
Displays the NTP configuration.
Step 5
write startup-config
Optional step – saves this configuration
to be part of the startup configuration.
The
“ntp disable”
command disables NTP in the switch. NTP can be enabled in Supermicro
switches only after configuring at least 1 NTP server.
The example below shows the commands used to configure NTP.
SMIS# configure terminal
SMIS(config)#
ntp enable
SMIS(config)#end
SMIS#
show ntp
[NTP] ntp running unicast mode
Server
Key Prefer