2-14
Reset Connector
The reset connector is located on
pins 3 and 4 of JF1 and attaches
to the reset switch on the computer
chassis. See the table on the right for
pin defi nitions.
Reset Button
Pin Defi nitions
(JF1)
Pin# Defi nition
3
Reset
4
Ground
Power Fail LED
The Power Fail LED connection is
located on pins 5 and 6 of JF1. Refer to
the table on the right for pin defi nitions.
PWR Fail LED
Pin Defi nitions
(JF1)
Pin# Defi nition
5
3.3V
6
Power Fail LED
Overheat (OH)/Fan Fail/PWR Fail/
UID LED
Connect an LED cable to pins 7 and
8 of JF1 to use the Overheat/Fan Fail/
Power Fail and UID LED connections.
The Red LED on pin 8 provides
warnings of an overheat, fan failure
or power failure. The Blue LED on pin
8 works as the UID LED indicator for
the front panel UID switch. Refer to the
table on the right for pin defi nitions.
OH/Fan Fail/ PWR Fail (Red) LED
and UID (Blue) LED
Pin Defi nitions (JF1)
Pin# Defi nition
7
Vcc
8
OH/Fan Fail/PWS Fail (Red) LED
and UID (Blue) LED
OH/Fan Fail/PWR Fail
LED Status (Red LED)
State Indication
Off
Normal
On
Overheat
Flashing
Fan Fail
NIC2 (Link/Activity) LED
The LED connections for LAN2 link/
activity are on pins 9 and 10 of JF1.
Attach LAN LED cables to display
network activity. See the table on the
right for pin defi nitions.
NIC1 LED
Pin Defi nitions
(JF1)
Pin# Defi nition
11
Activity
12
Link
NIC2 LED
Pin Defi nitions
(JF1)
Pin# Defi nition
9
Activity
10
Link
NIC1 (Link/Activity) LED
The LED connections for LAN1 link/
activity are on pins 11 and 12 of JF1.
Attach LAN LED cables to display
network activity. See the table on the
right for pin defi nitions.
Содержание H8DGU-LN4F+
Страница 1: ...USER S MANUAL Revision 1 1c SUPER H8DGU LN4F ...
Страница 9: ...Chapter 1 Introduction 1 3 Figure 1 1 H8DGU LN4F Image ...
Страница 20: ...1 14 H8DGU LN4F Serverboard User s Manual Notes ...
Страница 74: ...4 18 H8DGU LN4F Serverboard User s Manual Notes ...
Страница 76: ...A 2 H8DGU LN4F Serverboard User s Manual Notes ...