background image

11

10

SuperServer E100-9APP User's Manual

Chapter 1: Introduction

1.4 Motherboard Layout

Below is a layout of the X11SAN with jumper, connector and LED locations shown. See the 
table on the following page for descriptions. For detailed descriptions, pinout information and 
jumper settings, refer to Chapter 4.

Rear Features

The chassis rear holds input/output ports, described in chapter 3. 

Figure 1-2. Rear Chassis View

Rear Chassis Features

Item

Features

Description

1

Power Input Port

Use this port for the 40W DC power input.

2

DIO Port

A rear mounted DIO port is provided.

3

USB Ports

Four rear USB ports are provided.

4

MIC Port

This is a port for a 2.5-mm microphone cable.

5

Headphone Port

This is a port for a 2.5-mm headphone cable.

6

Grounding Screw

7

COM Ports

Four COM ports are provided here for use.

JMD1

JPW1

JMP1

JTPM1

JSMBUS1

J5

DESIGNED IN USA

A2SAN-L

REV:1.01

BAR CODE

JGP1

BT1

JCOM1: COM1/COM2

JCOM2: COM3/COM4

CPU1

FAN1

JPME2

JPF1

LAN1

LAN2

JD1

LVDS1

I-SATA1

JHDMI1

LED1

JLCDPWR1

JF1

JIP1

JPH1

AUDIO FP

USB6(3.1)

X

X

X

USB2/3

USB0/1

VGA

JF1

ON

PWR

RST

X

HDD LED
PWR LED

SPEAKER

JD1:

USB4/5(3.0)

USB4/5 (3.0)

JHDMI

JIP1

JPME2

USB2/3

USB0/1

JGP1

LAN1

CPU1

FAN1

LVDS1

I-SATA1

JF1

JCOM2

JLCDPWR1

JCOM1

BT1 AUDIO FP

JPH1

JD1

LED1

LAN2

USB6 (3.1)

VGA

JPF1

JSMBUS1

JTPM1

JMD1

JMP1

J5

JPW1

Figure 1-3. Motherboard Layout

6

7

5

4

2

1

3

 

Notes: 

• 

See Chapter 2 for detailed information on jumpers, I/O ports, and JF1 front panel connec-
tions. 

• 

Jumpers/LED indicators not indicated are used for testing only.

• 

Some connectors, jumpers and headers shown above may not be accessible or used by 
the system and therefore should be considered unsupported/unused.

Содержание E100-9APP

Страница 1: ...USER S MANUAL Revision 1 0 SuperServer E100 9APP...

Страница 2: ...ING SUCH HARDWARE SOFTWARE OR DATA Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California USA The State of California Cou...

Страница 3: ...ures 9 Rear Features 10 1 4 Motherboard Layout 11 Quick Reference Table 12 System Block Diagram 13 1 5 Server Installation and Setup 14 Unpacking the System 14 Warnings and Precautions 14 Adding Compo...

Страница 4: ...V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermi...

Страница 5: ...t Number Quantity 40W 12V 3 33A AC to DC lockable power adapter MCP 250 10124 0N 1 Audio Cable Phone Jack and Plug 3 5 mm L 100 mm MCP 280 10001 0B 1 Important Links For your system to work properly p...

Страница 6: ...HDMI one VGA DIO One DB 9 COM Four COM ports 2 x RS 232 2 x RS 232 422 485 Sound One Line out One Mic in Front Panel Power button two LED status indicators Dimensions Proprietary 7 68 x 5 94 x 1 73 1...

Страница 7: ...dphone cable 6 Grounding Screw 7 COM Ports Four COM ports are provided here for use JMD1 JPW1 JMP1 JTPM1 JSMBUS1 J5 DESIGNED IN USA A2SAN L REV 1 01 BAR CODE JGP1 BT1 JCOM1 COM1 COM2 JCOM2 COM3 COM4 C...

Страница 8: ...2 0 Headers USB6 USB 3 1 Type C Header VGA Back Panel VGA Port Figure 1 4 System Block Diagram Note This is a general block diagram and may not exactly represent the features on your motherboard See t...

Страница 9: ...ur system is not already fully integrated with system memory refer to Chapter 2 for details on compatible types of memory and the installation procedure Drives and Storage To add storage capabilities...

Страница 10: ...is necessary when removing or installing non hot swap components or when replacing a non redundant power supply 1 Use the operating system to power down the system 2 After the system has completely sh...

Страница 11: ...ution Exercise extreme care when installing or removing DIMM modules to prevent damage SO DIMM Installation 1 Position the SODIMM module s bottom key so it aligns with the receptive point on the slot...

Страница 12: ...GNSS Installing the M 2 Card 1 Gently insert the M 2 card into the connector 2 Use a screw to secure the M 2 card to the M2_SRW1 or M2_SRW2 standoff Figure 2 2 Installing an M 2 Expansion Card Mother...

Страница 13: ...USB 3 0 Pin Definitions Pin Definition Pin Definition 1 VBUS 10 VBUS 2 D1 N 11 D2 N 3 D1 P 12 D2 P 4 GND 13 GND 5 Stda_SSRX1 N 14 Stda_SSRX2 N 6 Stda_SSRX1 P 15 Stda_SSRX2 P 7 GND_DRAIN 16 GND_DRAIN...

Страница 14: ...n Definition 1 Signal 2 Ground Power Button The Power Button connection is located on pins 1 and 2 of JF1 Momentarily contacting both pins will power on off the system This button can also be configur...

Страница 15: ...ND 33 PETp0 32 SMB_DATA 31 PETn0 30 SMB_CLK 29 GND 28 1 5V 27 GND 26 GND 25 PERp0 24 3 3Vaux 23 PERn0 22 PERST 21 DET_CARD_PLUG 20 NC 19 NC 18 GND 17 NC 16 NC 15 GND 14 NC 13 REFCLK 12 NC 11 REFCLK 10...

Страница 16: ...other Link LED may be green amber or off to indicate the speed of the connection LAN1 2 LED Connection Speed Indicator LED Color Definition Off 10 Mb s Green 100 Mb s Amber 1 Gb s Power LED LED1 is t...

Страница 17: ...rivers and utilities it contains You may also use a utility to extract the ISO file if preferred After creating a DVD with the ISO files insert the disk into the DVD drive on your system and the displ...

Страница 18: ...rating systems The program monitors such system health information as CPU temperature system voltages system power consumption fan speed and provides alerts via email or Simple Network Management Prot...

Страница 19: ...when other keys are used such as F1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configure...

Страница 20: ...ion ROM Select Keep Current to display the current AddOn ROM setting Select Force BIOS to use the Option ROM display set by the system BIOS The options are Force BIOS and Keep Current 5 2 Main Page Wh...

Страница 21: ...this feature to force the system to wait until the F1 key is pressed if an error occurs The options are Disabled and Enabled INT19 Interrupt 19 Trap Response Interrupt 19 is the software interrupt tha...

Страница 22: ...nable and Unlock Disable Hardware Prefetcher Available when supported by the CPU If set to Enabled the hardware prefetcher will prefetch streams of data and instructions from the main memory to the L2...

Страница 23: ...n the C State package register The options are C0 C1 State C2 State C6 Non Retention State C6 Retention State and No Limit CPU C3 Report Select Enabled to allow the BIOS to report the CPU C3 State ACP...

Страница 24: ...of the PCI E port specified by the user The options are Gen 1 Generation 1 2 5 GT s Gen 2 Generation 2 5 GT s and Gen 3 Gen eration 3 8 GT s SLOT 7 PCI E 3 0 X16 This item configures the link speed of...

Страница 25: ...SATA Controller This item enables or disables the onboard SATA controller supported by the Intel PCH chip The options are Enabled and Disabled Memory RAS Reliability_Availability_Serviceability Confi...

Страница 26: ...er as an AHCI drive Select RAID to configure a SATA drive specified by the user as a RAID drive The options are IDE AHCI and RAID If the item above Configure SATA as is set to AHCI the following items...

Страница 27: ...d Disabled Maximum Payload Use this feature to select the setting for the PCI Express maximum payload size The options are Auto 128 Bytes 256 Bytes 512 Bytes 1024 Bytes 2048 Bytes and 4096 Bytes Relax...

Страница 28: ...ERMR6 SC0 ESCN and VT400 Redirection After BIOS POST Use this feature to enable or disable legacy console redirection after BIOS POST When set to Bootloader legacy console redirection is disabled befo...

Страница 29: ...le Redirection Select Enabled to use the SOL port for Console Redirection The options are Enabled and Disabled If the item above set to Enabled the following items will become available for user s con...

Страница 30: ...ith a remote host server The options are COM1 and SOL Terminal Type Use this feature to select the target terminal emulation type for Console Redirection Select VT100 to use the ASCII character set Se...

Страница 31: ...ounter counts the number of occurrences that a duplicate event must happen before the MECI counter is incremented This is a numeric value The default value is 1 METW The Multiple Event Time Window MET...

Страница 32: ...Yes and No Key Exchange Key KEK Set New Key Select Yes to load the KEK from the manufacturer s defaults Select No to load the KEK from a file The options are Yes and No Append Key Select Yes to add th...

Страница 33: ...from top to bottom to select devices Dual Boot Order 1 Dual Boot Order 2 Dual Boot Order 3 Append Key Select Yes to add the database from the manufacturer s defaults to the existing DB Select No to l...

Страница 34: ...ows the user to specify which UEFI devices are boot devices UEFI Boot Order 1 5 7 Save Exit Use this tab page to manage your exit from the Setup Utility Discard Changes and Exit Select this option to...

Страница 35: ...These are factory settings designed for maximum system stability but not for maximum performance Save As User Defaults To set this feature select Save as User Defaults from the Exit menu and press Ent...

Страница 36: ...r the corresponding error All errors listed with the exception of Beep Code 8 are fatal errors BIOS Beep POST Codes Beep Code Error Message Description 1 beep Refresh Circuits have been reset Ready to...

Страница 37: ...it den Gefahren elektrischer Schaltungen und den blichen Verfahren zur Vorbeugung vor Unf llen vertraut Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen berset...

Страница 38: ...AR DEZE INSTRUCTIES Installation Instructions Warning Read the installation instructions before connecting the system to the power source Warnung Vor dem Anschlie en des Systems an die Stromquelle die...

Страница 39: ...er of het beveiligde aparaat niet groter gedimensioneerd is dan 12V 3 3A Power Disconnection Warning Warnung Das System muss von allen Quellen der Energie und vom Netzanschlusskabel getrennt sein das...

Страница 40: ...dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o utilizar este equipo Restricted Area Waarschuwi...

Страница 41: ...lleen verkregen worden door gebruik te maken van speciaal gereedschap slot en sleutel of andere veiligheidsmaatregelen Battery Handling Warnung Bei Einsetzen einer falschen Batterie besteht Explosions...

Страница 42: ...e worden Comply with Local and National Electrical Codes Warnung Die Installation der Ger te muss den Sicherheitsstandards entsprechen Advertencia La instalacion del equipo debe cumplir con las normas...

Страница 43: ...lieren des Produkts ausschlie lich die von uns zur Verf gung gestellten Verbindungskabeln Stromkabeln und oder Adapater die Ihre rtlichen Sicherheitsstandards einhalten Der Gebrauch von anderen Kabeln...

Страница 44: ...CA que cumplan con los c digos locales y los requisitos de seguridad incluyendo el tama o adecuado del cable y el enchufe El uso de otros cables y adaptadores podr a causar un mal funcionamiento o un...

Страница 45: ...perating Environment Operating Temperature 0 C to 40 C 32 F to 104 F Non operating Temperature 40 C to 70 C 40 F to 158 F Operating Relative Humidity 8 to 90 non condensing Non operating Relative Humi...

Страница 46: ...Manual A 1 Traditional Chinese Version Safety Warnings Additional Traditional Chinese Version warning statements are included here in this appendix Warning Caution Warnings 1 12V 10 2 3 4 A 2 Traditi...

Страница 47: ...1 wt 0 01 wt Note 1 Exceeding 0 1 wt and exceeding 0 01 wt indicate that the percentage content of the restricted substance exceeds the reference percentage value of presence condition 2 Note 2 indic...

Страница 48: ...BIOS image The boot block contains critical BIOS codes including memory detection and recovery codes for the user to flash a new BIOS image if the original main BIOS image is corrupted When the syste...

Страница 49: ...UEFI is FAT including FAT12 FAT16 and FAT32 which is installed on a bootable or non bootable USB attached device However the BIOS might need several minutes to locate the SUPER ROM file if the media s...

Страница 50: ...art the BIOS update process Note Do not interrupt this process until the BIOS flashing is complete 10 The screen above indicates that the BIOS update process is completed When you see the screen above...

Отзывы: