Chapter 3: System Interface
3-3
NIC1
Indicates network activity when flashing.
HDD and NIC2
These indicators are not used in the JBOD system.
Information LED
Alerts operator to several states, as noted in the table below.
Information LED
Status
Description
Continuously on and red
An overheat condition has occurred.
(This may be caused by cable congestion.)
Blinking red (1Hz)
Fan failure, check for an inoperative fan.
Blinking red (0.25Hz)
Power failure, check for a non-operational power supply.
Solid blue
Local UID has been activated. Use this function to locate
the server in a rack mount environment.
Blinking blue
Remote UID is on. Use this function to identify the
server from a remote location.
1
2
Power Fail
Indicates a power supply module has failed.
!