2-4
SAS2-936EL Series Backplane
User's Guide
General Jumper Settings
Jumper
Jumper Settings
Note
PRI_MODE1
2-3
Factory setting
do not change
PRI_MODE2
2-3
Factory setting
do not change
SEC_MODE1
2-3
Factory setting
do not change
SEC_MODE2
2-3
Factory setting
do not change
FAN_MONITOR_DIS-
ABLE
Open: Enabled (Default)
Closed: Disabled
Fan monitor reports
FAN_LED_DISABLE
Closed (Default)
Turns off the FANFAIL1 LED
BUZZER_ENB1
Open: Disable
Closed: Enable (Default)
Buzzer disabled*
Buzzer enabled*
*The buzzer sound indicates that a condition requiring immediate attention has
occurred.
The buzzer alarm is triggered by the following conditions:
1. Hard drive failure
2. Fan failure
3. System temperature over 45º Celsius.
Early versions of Supermicro SAS2 backplanes come equipped with a buzzer. New
versions of these backplanes no longer support a buzzer. We recommend using
the LSI MegaRAID Storage Manager or a similar management application to trigger
an email alert instead.