background image

S

UPER

S

ERVER

®

 

7048R-C1RT

7048R-C1R

USER’S MANUAL

 

1.0a

Проконсультироваться

 

и

 

купить

 

данное

 

оборудование

 

вы

 

можете

 

в

 

компании

 «

АНД

-

Системс

»  

адрес

: 125480, 

г

.

Москва

ул

.

Туристская

д

.33/1; site: https://andpro.ru 

тел

: +7 (495) 545-4870 email: [email protected] 

При

 

обращении

 

используйте

 

промокод

 AND-PDF 

и

 

получите

 

скидку

Содержание 7048R-C1R

Страница 1: ...SUPERSERVER 7048R C1RT 7048R C1R USER S MANUAL 1 0a 125480 33 1 site https andpro ru 7 495 545 4870 email info andpro ru AND PDF...

Страница 2: ...pt as expressly permitted by the terms of said license IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILI...

Страница 3: ...ng the serverboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC745TQ R920B server chassis You should follow the procedures given in this chapter when installi...

Страница 4: ...3 1 Overview 3 1 3 2 Control Panel Buttons 3 1 vii SUPERSERVER 7048R C1RT 7048R C1R User s Manual Power 3 1 Reset 3 1 3 3 Control Panel LEDs 3 2 Power 3 2 HDD 3 2 NIC1 3 2 NIC2 3 2 Information LED 3 3...

Страница 5: ...ilure 6 4 6 4 Drive Bay Installation 6 6 SAS SATA Hard Drives 6 6 SAS SATA Backplane 6 7 Mobile Rack Storage Module 6 8 6 5 Power Supply 6 10 Power Supply Failure 6 10 Chapter 7 BIOS 7 1 Introduction...

Страница 6: ...eatsinks SNK P0048PS Three 8 cm system fans FAN 0074L4 Two 8 cm rear exhaust fans FAN 0082L4 Air shroud MCP 310 49001 0N SAS SATA Accessories One SAS SATA backplane BPN SAS 743TQ Eight drive carriers...

Страница 7: ...x8 slots and one PCI E 3 0 x16 slot Note that the PCI slots are controlled by the CPUs so only three slots Slot1 Slot3 are available if both CPUs are not installed on the board at the same time CPU1 S...

Страница 8: ...235 Taiwan R O C Tel 886 2 8226 3990 Fax 886 2 8226 3992 Email support supermicro com tw Website www supermicro com tw SPI LAN3 RGRMII Debug Card FRONT PANEL SYSTEM POWER CTRL FAN SPEED PCI E X1 G2 US...

Страница 9: ...1 6 SUPERSERVER 7048R C1RT 7048R C1R User s Manual Notes...

Страница 10: ...le a damage claim with the carrier who delivered it Decide on a suitable location for the SuperServer 7048R C1RT 7048R C1R It should be situated in a clean dust free area that is well ventilated Avoid...

Страница 11: ...losed or multi unit rack assembly the ambient operating tempera ture of the rack environment may be greater than the ambient temperature of the room Therefore consideration should be given to installi...

Страница 12: ...a Rack This section provides information on installing the system into a rack unit Rack installation requires the use of the optional rackmount kit If the system has already been mounted into a rack...

Страница 13: ...the Rack Rails Determine where you want to place the SuperServer 7048R C1RT 7048R C1R in the rack See Rack and Server Precautions in Section 2 3 Position the fixed rack rail sliding rail guide assembl...

Страница 14: ...2 8 SUPERSERVER 7048R C1RT 7048R C1R User s Manual Notes...

Страница 15: ...status of the system and the activity and health of specific components 3 2 Control Panel Buttons There are two push buttons located on the front of the chassis a power on off button and a reset butt...

Страница 16: ...ng normally You should also check to make sure that the chassis covers are installed Finally verify that the heatsinks are installed properly see Chapter 5 This LED will remain flashing or on as long...

Страница 17: ...3 4 SUPERSERVER 7048R C1RT 7048R C1R User s Manual Notes...

Страница 18: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Страница 19: ...el apartado de traducciones que acompa a a este dispositivo GUARDE ESTAS INSTRUCCIONES IMPORTANTES INFORMATIONS DE S CURIT Ce symbole d avertissement indique un danger Vous vous trouvez dans une situa...

Страница 20: ...Ensure that the protective device is rated not greater than 250 V 20 A Waarschuwing Raadpleeg de installatie instructies voordat u het systeem op de voedingsbron aansluit 250 V 20 A Warnung Dieses Pro...

Страница 21: ...itbeveiliging overspanning van uw electrische installatie Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 220V 20A Advertencia El sistema debe ser disconnected de todas las fue...

Страница 22: ...d de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Waarschuwing Deze apparatuur mag alleen worden ge nstalleerd vervangen of herst...

Страница 23: ...type semblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de maner...

Страница 24: ...ltage Warnung Wenn das System in Betrieb ist treten auf der R ckwandplatine gef hrliche Spannungen oder Energien auf Vorsicht bei der Wartung Advertencia Cuando el sistema est en funcionamiento el vol...

Страница 25: ...les Product Disposal Warning Ultimate disposal of this product should be handled according to all national laws and regulations Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig o...

Страница 26: ...y s housing Hot Swap Fan Warning Warnung Die L fter drehen sich u U noch wenn die L fterbaugruppe aus dem Chassis genommen wird Halten Sie Finger Schraubendreher und andere Gegenst nde von den ffnunge...

Страница 27: ...er Fehlfunktion oder ein Brand entstehen Elektrische Ger te und Material Safety Law verbietet die Verwendung von UL oder CSA zertifizierte Kabel UL oder CSA auf der Code f r alle anderen elektrischen...

Страница 28: ...4 20 SUPERSERVER 7048R C1RT 7048R C1R User s Manual Notes...

Страница 29: ...that the size and weight of the serverboard can cause it to bend if handled improperly which may result in damage To prevent the serverboard from bending keep one hand under the center of the board t...

Страница 30: ...ver labeled Open 1st OPEN1st OPEN1st Release the lever labeled Close 1st 2 Press the second load lever labeled Close 1st to release the load plate from its locked position 3 With the second lever full...

Страница 31: ...ith those on the serverboard s and the heatsink bracket underneath 3 Screw in two diagonal screws i e the 1 and the 2 screws until just snug to avoid possible damage to the CPU do not over tighten the...

Страница 32: ...ing the system keep the airflow in mind when routing the cables Connecting Power Cables The X10DRH CT C has a 24 pin ATX power connector designated J24 and two 8 pin primary power supply connectors de...

Страница 33: ...the memory to work properly follow the tables below for memory installation Socket Key Release Tab Release Tab Processors and their Corresponding Memory Modules CPU Corresponding DIMM Modules CPU 1 P...

Страница 34: ...P2 DIMMH2 P1 DIMMA2 P1 DIMMB1 P2 DIMMH1 P1 DIMMA1 P2 DIMMG2 VGA P2 DIMMG1 LAN2 LAN1 3 0 IPMI_LAN COM1 PWR I2C CPU2 SLOT7 PCI E 3 0 X8 FAN4 J24 X10DRH C i T Rev 1 00 JPB1 JPL1 TFM LE2 CPU2 SAS0 3 LSI...

Страница 35: ...by Intel SCU SAS 0 3 4 7 SAS 3 0 Ports 0 3 4 7 supported by the LSI 3108 I SGPIO1 2 Serial Link General Purpose I O Headers 1 2 for SATA ports I SGPIO1 for I SATA0 3 I SGPIO2 for I SATA4 5 UID UID Uni...

Страница 36: ...ure or power failure The Blue LED on pin 7 works as the front panel UID LED indicator Refer to the table on the right for pin definitions PWR Fail LED Pin Definitions JF1 Pin Definition 5 3 3V 6 PWR S...

Страница 37: ...Pin Definition Pin Definition 1 5V 5 5V 2 USB_PN1 6 USB_PN0 3 USB_PP1 7 USB_PP0 4 Ground 8 Ground USB 4 5 6 7 8 USB 3 0 Pin Definitions Pin Description 1 VBUS 2 SSRX 3 SSRX 4 Ground 5 SSTX 6 SSTX 7 G...

Страница 38: ...e Port 80 header is located at JTPM1 to provide TPM support and Port 80 connection Use this header to enhance system performance and data security See the table on the right for pin definitions TPM Po...

Страница 39: ...umpers can be used to choose between optional settings Jumpers create shorts between two pins to change the function of the connector Pin 1 is identified with a square solder pad on the printed circui...

Страница 40: ...le on the right for jumper settings BMC Enable Jumper Settings Jumper Setting Definition Pins 1 2 BMC Enable Pins 2 3 Normal 5 9 Onboard Indicators I2 C Bus to PCI Exp Slots Use Jumpers JI2 C1 and JI2...

Страница 41: ...erboard When LEDS6 is on a SAS error has occurred SAS Error LED LED States Color State Definition Red On SAS error s detected SATA 3 0 Ports Ten SATA 3 0 ports are located on the serverboard Six SATA...

Страница 42: ...install each item from top to the bottom one at a time After installing each item you must reboot the system before moving on to the next item on the list The bottom icon with a CD on it allows you to...

Страница 43: ...attery in any way a damaged battery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please comply with the regulations set up by...

Страница 44: ...ortant to handle them very carefully The following measures are generally sufficient to protect your equipment from static discharge Precautions Use a grounded wrist strap designed to prevent static d...

Страница 45: ...hassis The LEDs on the control panel inform you of system status See Figure 6 2 for details See Chapter 5 for details on JF1 Figure 6 2 Front Control Panel LEDs Power NIC1 HDD Power Fail Overheat Fan...

Страница 46: ...ess where it says push then lift the latch to release the cover 5 Lift the cover from the chassis to gain full access to the inside of the server Replacing Chassis Cooling Fans 1 Depress the locking t...

Страница 47: ...ft to right depending on their orientation A bezel covers the drive area but does not need to be removed to access the drives simply swing open the bezel If you wish to remove the bezel piece push on...

Страница 48: ...e system Mobile Rack Storage Module If the 7048R C1RT 7048R C1R is to be used in a rack configuration you must rotate the mobile rack enclosure module 90 degrees This can be done before during or afte...

Страница 49: ...e power supply modules allows you to replace the failed module without powering down the system Replacing the Power Supply You do not need to shut down the system to replace a power supply module The...

Страница 50: ...options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selecte...

Страница 51: ...he memory modules installed in the system How to Start the Setup Utility Normally the only visible Power On Self Test POST routine is the memory test As the memory is being tested press the Delete key...

Страница 52: ...Interrupt 19 at bootup immediately and allow the drives that are attached to the host adap tors to function as bootable disks If this item is set to Postponed the ROM BIOS of the host adaptors will n...

Страница 53: ...d Disable Direct Cache Access DCA Select Enable to use Intel DCA Direct Cache Access Technology to improve the efficiency of data transferring and accessing The options are Auto Enable and Disable X2...

Страница 54: ...re components only Select SW_ALL to change the P state coordination type for all software installed in the system Select SW_ANY to change the P state coordination type for a soft ware program in the s...

Страница 55: ...its frequency and voltage scaled back a notch The options are Between P1 P0 and Below P1 DRAM RAPL Running Average Power Limit Configuration DRAM RAPL Running Average Power Limit Baseline Use this it...

Страница 56: ...rror logic for the port specified by the user The options are Disable and Enable Corr Err Correctable Error Over Select Enable to force correctable error prorogation to the IIIO core error logic for t...

Страница 57: ...Generation 3 DN TX Preset Use this item to set the Preset mode for PCI E Gen3 downstream transmit ting TX from the master device to a slave device The options are Auto P0 6 0 0 0 dB P1 3 5 0 0 dB P2...

Страница 58: ...th of time required for the port specified by the user to complete the transition from L1 to L0 The default setting is 1uS 1uS 2uS 2uS 4uS 4uS 8uS 8uS 16uS 16uS 32uS 32uS 64uS and 64uS Fatal Err Error...

Страница 59: ...her tasks The options are Enable and Disable No Snoop Select Enable to support no snoop mode for each CB device The options are Disable and Enable Relaxed Ordering Select Enable to enable Relaxed Orde...

Страница 60: ...M RAPL Mode 0 and DRAM RAPL Mode 1 Set Throttling Mode Throttling improves CPU reliability and reduces power consumption via automat ic voltage control during CPU idle states The options are Disabled...

Страница 61: ...ll USB devices available for EFI applications only The options are Enabled Disabled and Auto XHCI Hand Off This is a work around solution for operating systems that do not support XHCI Ex tensible Hos...

Страница 62: ...t specified by the user should be con nected to a Solid State drive or a Hard Disk Drive The options are Hard Disk Drive and Solid State Drive If the item above Configure SATA as is set to IDE the fol...

Страница 63: ...er of drive and capacity sSATA Port 0 Port 3 Select Enabled to enable an sSATA port specified by the user The options are Disabled and Enabled Spin Up Device On an edge detect from 0 to 1 set this ite...

Страница 64: ...to allow a PCI device to generate a PERR PCI PCI E Parity Error number for a PCI bus error event The options are Enabled and Disabled SERR Generation Select Enabled to allow a PCI device to generate a...

Страница 65: ...ble Firmware Interface for network stack support The options are Enabled and Disabled Super IO Configuration Super IO Chip AST2400 Serial Port 1 Configuration Serial Port 2 Configuration Serial Port 1...

Страница 66: ...packet Select 1 Stop Bit for standard serial data communication Select 2 Stop Bits if slower devices are used The options are 1 and 2 Flow Control Use this item to set the flow control for Console Red...

Страница 67: ...ptions are 1 and 2 Flow Control Use this feature to set the flow control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receivi...

Страница 68: ...to set the flow control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop data sending when the receiving buffer is full Send a Start signal to start d...

Страница 69: ...board PCI devices The options are Disabled and Enabled iSCSI Configuration This item displays iSCSI configuration information iSCSI Initiator Name Use this item to enter the name of the iSCSI Initiato...

Страница 70: ...er Enter a number between 1 to 255 The default setting is 1 METW Multiple Event Count Time Window This item is used to determine how long in minutes the multiple event counter should wait before gener...

Страница 71: ...tocol server attached to the network and request the next available IP address for this computer The options are DHCP and Static Station IP Address This item displays the Station IP address for this c...

Страница 72: ...Boot Option 1 Boot Option 15 When the item above Boot Mode Select is set to Legacy the following items will be display for configuration Boot Option 1 Boot Option 7 When the item above Boot Mode Selec...

Страница 73: ...this item to save all changes made This will not reset reboot the system Discard Changes Select this item to discard all the changes and return to the AMI BIOS setup utility Select Yes and press Ente...

Страница 74: ...7 48 SUPERSERVER 7048R C1RT 7048R C1R User s Manual Notes...

Страница 75: ...e usually communicated through a series of audible beeps The numbers on the fatal error list on the following page correspond to the number of beeps for the corresponding error All errors listed with...

Страница 76: ...A 2 SUPERSERVER 7048R C1RT 7048R C1R User s Manual Notes...

Страница 77: ...Capacity Sixteen DIMM slots that can support up to 2 TB of Load Reduced LRDIMM registered ECC or up to 1 TB of registered ECC RDIMM DDR4 2400 2133 1866 1600 memory Note See Section 5 5 for details SAS...

Страница 78: ...2V 75A 5Vsb 4A Operating Environment Operating Temperature 10 to 35 C 50 to 95 F Non operating Temperature 40 to 70 C 40 to 158 F Operating Relative Humidity 20 to 95 non condensing Non operating Rela...

Страница 79: ...to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell s...