![Supermicro 6048R-E1CR24N Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/supermicro/6048r-e1cr24n/6048r-e1cr24n_user-manual_1404818050.webp)
Chapter 6: Advanced Chassis Setup
6-9
6-8
S
UPER
S
TORAGE
S
YSTEM 6048R-E1CR24N User's Manual
Removing the Air Shroud
Under most circumstances you will not need to remove the air shroud to perform
any service on the system. However, if you need to temporarily remove it (the air
shroud sould always be in place when the system is operating), please follow this
procedure.
Air shrouds concentrate airflow to maximize fan efficiency. The SC846 chassis air
shroud does not require screws to set up
Installing the Air Shroud
1.
Confirm that your air shroud matches your chassis model. Each shroud is
labeled SC846LP, SC846RC, or SC846U.
2.
Place the air shroud in the chassis. The air shroud fits behind the two fans
closest to the power supply.
Figure 6-6. Removing the Air Shroud
6-6 Power Supply
The SuperServer 6048R-E1CR24N has a 920 watt redundant, hot-plug power
supply consisting of two power modules. Each power supply module has an auto-
switching capability, which enables it to automatically sense and operate at a 100V
- 240V input voltage.
Power Supply Failure
If either of the two power supply modules fail, the other will take the full load and
allow the system to continue operation without interruption. The Power Fail LED will
illuminate and remain on until the failed module has been replaced. Replacements
can be ordered directly from Supermicro (see contact information in the Preface).
The power supply modules have a hot-swap capability, meaning you can replace
the failed module without powering down the system.
Removing/Replacing the Power Supply
1. First unplug the power cord from the failed power supply module.
2. Push the release tab on the back of the power supply as illustrated
3. Pull the power supply out using the handle provided.
4. Replace the failed power module with another of the same model.
5. Push the new power supply module into the power bay until it clicks into the
locked position.
6. Plug the AC power cord back into the module.
Содержание 6048R-E1CR24N
Страница 1: ...SUPER STORAGE SYSTEM 6048R E1CR24N USER S MANUAL 1 0b ...
Страница 6: ...SUPERSTORAGESYSTEM 6048R E1CR24N User s Manual x Notes ...
Страница 10: ...1 6 SUPERSTORAGESYSTEM 6048R E1CR24N User s Manual Notes ...
Страница 18: ...3 4 SUPERSTORAGESYSTEM 6048R E1CR24N User s Manual Notes ...
Страница 29: ...4 20 SUPERSTORAGESYSTEM 6048R E1CR24N User s Manual Notes ...
Страница 45: ...5 30 SUPERSTORAGESYSTEM 6048R E1CR24N User s Manual Notes ...
Страница 52: ...6 12 SUPERSTORAGESYSTEM 6048R E1CR24N User s Manual Notes ...
Страница 76: ...A 2 SUPERSTORAGESYSTEM 6048R E1CR24N User s Manual Notes ...