1-8
SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL
1-6 2U Twin: System Notes
As a 2U Twin confi guration, the SuperServer 6027TR-D71RF/D71QRF/D71FRF is
a unique server system. With two system boards incorporated into a single chassis
acting as two separate nodes, there are several points you should keep in mind.
Nodes
Each of the two serverboards act as a separate node in the system. As independant
nodes, each may be powered off and on without affecting the others. In addition,
each node is a hot-swappable unit that may be removed from the rear of the chassis.
The nodes are connected to the server backplane by means of an adapter card.
Note:
A guide pin is located between the upper and lower nodes on the inner chassis
wall. This guide pin also acts as a “stop” when a node is fully installed. If too much
force is used when inserting a node this pin may break off. Take care to slowly slide
a node in until you hear the “click” of the locking tab seating itself.
System Power
Dual 1280 Watt power supply is used to provide the power for all serverboards.
Each serverboard however, can be shut down independently of the other with the
power button on its own control panel. As an option, you may add an additional
1280 Watt power supply module for power redundancy.
SATA/SAS Backplane/Drives
As a system, the SuperServer 6027TR-D71RF/D71QRF/D71FRF supports the use
of twelve SATA/SAS drives. A single SATA/SAS backplane works to apply system-
based control for power and fan speed functions, yet at the same time logically
connects a set of six SATA/SAS drives to each serverboard. Consequently, RAID
setup is limited to a six-drive scheme (RAID cannot be spread across all twelve
drives). See the Drive Bay Installation/Removal section in Chapter 6 for the logical
hard drive and node confi guration.
Содержание 6027TR-D71FRF SUPERSERVER SUPERO
Страница 1: ...SUPER SUPERSERVER Revision 1 0 SUPERSERVER 6027TR D71RF 6027TR D71QRF 6027TR D71FRF...
Страница 5: ...v SUPERSERVER 6027TR D71RF D71QRF D71FRF SUPERSERVER Notes...
Страница 10: ...SUPERSERVER 6027TR D71RF D71QRF D71FRF SUPERSERVER x Notes...
Страница 30: ...SUPERSERVER 6027TR D71RF D71QRF D71FRF USER S MANUAL 3 4 Notes...
Страница 50: ...4 20 SUPERSERVER 6027TR D71QRF D71FRF D71RF User s Manual Notes...
Страница 85: ...Chapter 6 Advanced Chassis Setup 6 7 Figure 6 5 Replacing a System Fan in the Fan Housing...
Страница 100: ...6 22 SUPERSERVER 6027TR D71RF D71QRF D71FRF USER S MANUAL Figure 6 20 Changing the Power Supply Release Tab...
Страница 128: ...7 28 SUPERSERVER 6027TR D71RF D71QRF D71FRF USER S MANUAL Notes...
Страница 130: ...A 2 SUPERSERVER 6027TR D71RF D71QRF D71FRF USER S MANUAL Notes...
Страница 133: ...B 3 Appendix B System Specifications Notes...