Superlift RDO-1BP Скачать руководство пользователя страница 14

 

-  14  -

                                                                                                            RDO1BP  B

 

SETTINGS AND ADJUSTMENTS 

 
 
18.  Safety Beams - Installation 

 

18.1

 

Locate the Safety Beam Mounting Brackets provided. 

18.2

 

Mark the inside door framing so that the bottom edge of the Mounting Brackets sit 125mm off the floor. 

18.3

 

Use the 2 mounting screws provided to fasten each Mounting Bracket to the wall. Do not over tighten the fixing 
screws as the Mounting Brackets will need to undergo adjustment at a later time. 

18.4

 

Use the 2 screws and nuts provided to fasten the Safety Beams to the Mounting Brackets so that the Indicator 
Lamp on each Safety Beam is facing upwards. 

18.5

 

Using Figure 8 cable, strip back and connect the 2 strands of one end of the cable to each of the 2 terminals 
located on the outer cover of each Safety Beam. 

18.6

 

Securely fix the cable up and along the wall and run one length of each cable over to the Control Box. (Fig.3) 

18.7

 

Strip back and connect one strand of each cable to the terminals marked 9B & 9C (Fig.1) 

18.8

 

A green pilot light on the “emitter” will illuminate to indicate that the Safety Beams have been connected 
correctly 

18.9

 

Enable Dip Switch No.1 by selecting it to the “on” position (Fig.1, Item 1) 

18.10

 

Important Note: For the Safety Beams to function correctly the jumper plug J8 located on the control 
board (Fig.1, Item 12) of the AGDO must be positioned so that the middle and right hand pins are 
connected.

 

18.11

 

Important Note: The AGDO will only support the fitment of genuine Superlift Brand 2 wire Safety Beams.

 

 

19.  Safety Beams - Alignment 

 

19.1

 

Align the 2 Safety Beams (by turning the mounting bracket) so that their lenses are aimed directly at each other. 
A red indicator lamp on the “receiver” will glow solid once correct alignment has been achieved. 

19.2

 

Test the Safety Beam alignment several times, each time ensuring that when the Safety Beams are obstructed the 
red indicator lamp is extinguished, and when unobstructed the indicator lamp glows solid. 

19.3

 

Firmly tighten the Safety Beam mounting bracket fixing screws. 

19.4

 

Installation of Safety Beams is now complete. 

 

20.  Safety Beam – Function Testing 

 

20.1

 

Initiate a closing cycle on the AGDO and as the Garage Door is closing pass your hand through the line of the 
Safety Beams. If the Safety Beams are functioning correctly the AGDO should stop and then immediately 
reverse direction. 

20.2

 

If the Garage Door commences a close cycle but stops and reverses before the Safety Beams are blocked, check 
that the Safety Beams are aligned correctly as outlined in points 18.1 ~ 18.3 

 

21.  Auto Close Mode 

 

21.1

 

In Auto Close Mode the AGDO will automatically close a pre set time after it reaches the fully open position. 

21.2

 

To enable Auto Close Mode move dip switch No.2 to the “ON” position. (Fig.1) 

21.3

 

The Auto Close pre set time is determined by the position of dip switches Nos. 3 & 4 (Fig.1) and is set out in the 
following table: 15 sec = Dip 3&4 Down    b. 30 sec = Dip 3&4 Up

 

 

21.4

 

Important Note: Auto Close Mode will only work if Safety Beams have been enabled and correctly aligned 

 

22.  Output Terminals

 

 

22.1

 

The AGDO provides a 24VDC external power supply to support the connection of external accessories. 

22.2

 

The values of the output terminals is set out in the following table: 9A ~ Com, 9B ~ Neg, 9C ~ +24VDC (Fig.1) 

22.3

 

Important Note: For connection of any external accessory other than Safety Beams the jumper plug J8 
located on the control board of the AGDO must be positioned so that the middle and left hand pins are 
connected. 

 
 
 
 
 

Содержание RDO-1BP

Страница 1: ...801 001 03 ...

Страница 2: ... automotive bearing grease Failure to adequately lubricate the springs may result in one or more of the following symptoms a The springs will become rusty over time resulting in extra operating friction between the coils which may cause the AGDO to malfunction b Seasonal temperature changes may cause the Garage Door springs to expand and or contract The resultant increase and or decrease in operat...

Страница 3: ...carried out by a technically qualified person Attempting to adjust the Safety Reverse Force setting without suitable technical qualification may result in severe personal injury death and or property damage 26 Keep hands and loose clothing clear of the Garage Door and Product at all times 27 In order for the Safety Obstruction Force System to function it must first encounter an object person on to...

Страница 4: ... 4 RDO1BP B OPERATING CONTROLS Fig 1 Fig 1A Fig 2 Fig 2A Fig 3 Fig 3A ...

Страница 5: ...or remote mounted push button refer Sec 17 18 22 10 RADIO RECEIVER processes the signal from the hand held transmitter 11 AUTO COURTESY LIGHT is activated automatically each time the opener commences an open or close cycle and remains on for approx 3 minutes 12 JUMPER PLUG J8 switches power supply for use with either one of Safety Beams or External Receiver refer Sec 18 13 OPEN LIMIT CAM is used t...

Страница 6: ...al check measurement prior to mounting or moving any garage door brackets Fig 5 C Check For Correct Function Of The Door Before beginning the installation of the AGDO check that the garage door is functioning correctly The garage door must be well balanced and operate smoothly and freely When opened to between 900 1200mm from the floor and released the garage door should remain in one fixed positi...

Страница 7: ...tain damage as a result of any water intrusion Water damaged electronics are not covered under the terms of the opener warranty Important Note The control box is not water proof H Battery Charger The plug pack battery charger is provided to keep the batteries charged to an optimum voltage A red coloured LED located on the charger casing will illuminate to indicate that the charger has been connect...

Страница 8: ...l not hook on to the screws or if the Control Box does hook on but is loose 1 7 At this stage DO NOT plug the Charger into a power socket 2 Fitting Of Drive Unit To The Door Right Hand Installation Depicted 2 1 Check that the door U bolt is securely tightened on the opposite end of the door to which the Drive Unit will be fitted Fig 7 2 2 Open the door fully and ensure that the bottom stoppers of ...

Страница 9: ... forks of the Drive Unit 2 10 Refit the garage door mounting bracket to the wall The U Bolt slots in the door bracket must align with the U bolt mounting slots in the Drive Unit Fig 10 2 11 Important Note In some cases the door mounting bracket may need to be re positioned in order that the U Bolt holes align 2 12 Fully insert the specially supplied U bolt through the Drive Unit and garage door mo...

Страница 10: ...re that there are no persons and or property near or directly under the path of the garage door Release Chord Fig 11 Fig 12 5 Fitting of Weight Bar 5 1 Fit the weight bar to the top edge of the garage door bottom rail as depicted in Fig 12 6 Fixing Of Curtain To Drum Wheel 6 1 The garage door curtain must be secured to the drum wheel with suitable fasteners such as self drilling screws or rivets 6...

Страница 11: ...am accordingly 9 Connecting to Power Supply 9 1 Connect the AGDO Battery Charger to a properly earthed power supply 9 2 Switch the power on at the power supply the LED on the charger should glow red 10 Door Travel Final Adjustment 10 1 Open the garage door to a midway position and then pull once on the red disengage cord to engage the AGDO to the garage door 10 2 Test the garage door open and clos...

Страница 12: ...e adjustment by pressing the red button again This time the door should reach the fully OPEN position without stopping 13 Safety Obstruction Force Testing Close Direction 13 1 With the garage door in the fully open position place a length of timber measuring 100mm x 50mm on the floor directly under the middle of the garage door Fig 14 13 2 With the garage door in the fully open position close the ...

Страница 13: ...top right corner of the Control Box Fig 4 15 4 Momentarily press the Code Set button red coding indicator lamp will glow solid 15 5 Momentarily press the hand transmitter button red coding indicator lamp will extinguish 15 6 Momentarily press the hand transmitter button once again red coding indicator lamp will begin to flash once flashing stops the coding sequence has been completed 15 7 Test for...

Страница 14: ... A red indicator lamp on the receiver will glow solid once correct alignment has been achieved 19 2 Test the Safety Beam alignment several times each time ensuring that when the Safety Beams are obstructed the red indicator lamp is extinguished and when unobstructed the indicator lamp glows solid 19 3 Firmly tighten the Safety Beam mounting bracket fixing screws 19 4 Installation of Safety Beams i...

Страница 15: ... does not close fully Limit micro switch incorrectly adjusted Re adjust limit switch Refer Installation Instruction Item 3 Lights malfunction globe blown Replace with 24VDC 3W globe Door Stops on Upward cycle before reaching the fully open position Door may be obstructed Door springs may have lost tension Safety Obstruction Force may need adjustment Disengage Opener and check door for free movemen...

Страница 16: ... 16 RDO1BP B CONTROL BOX MOUNTING TEMPLATE ...