- 14 -
RDO1BP B
SETTINGS AND ADJUSTMENTS
18. Safety Beams - Installation
18.1
Locate the Safety Beam Mounting Brackets provided.
18.2
Mark the inside door framing so that the bottom edge of the Mounting Brackets sit 125mm off the floor.
18.3
Use the 2 mounting screws provided to fasten each Mounting Bracket to the wall. Do not over tighten the fixing
screws as the Mounting Brackets will need to undergo adjustment at a later time.
18.4
Use the 2 screws and nuts provided to fasten the Safety Beams to the Mounting Brackets so that the Indicator
Lamp on each Safety Beam is facing upwards.
18.5
Using Figure 8 cable, strip back and connect the 2 strands of one end of the cable to each of the 2 terminals
located on the outer cover of each Safety Beam.
18.6
Securely fix the cable up and along the wall and run one length of each cable over to the Control Box. (Fig.3)
18.7
Strip back and connect one strand of each cable to the terminals marked 9B & 9C (Fig.1)
18.8
A green pilot light on the “emitter” will illuminate to indicate that the Safety Beams have been connected
correctly
18.9
Enable Dip Switch No.1 by selecting it to the “on” position (Fig.1, Item 1)
18.10
Important Note: For the Safety Beams to function correctly the jumper plug J8 located on the control
board (Fig.1, Item 12) of the AGDO must be positioned so that the middle and right hand pins are
connected.
18.11
Important Note: The AGDO will only support the fitment of genuine Superlift Brand 2 wire Safety Beams.
19. Safety Beams - Alignment
19.1
Align the 2 Safety Beams (by turning the mounting bracket) so that their lenses are aimed directly at each other.
A red indicator lamp on the “receiver” will glow solid once correct alignment has been achieved.
19.2
Test the Safety Beam alignment several times, each time ensuring that when the Safety Beams are obstructed the
red indicator lamp is extinguished, and when unobstructed the indicator lamp glows solid.
19.3
Firmly tighten the Safety Beam mounting bracket fixing screws.
19.4
Installation of Safety Beams is now complete.
20. Safety Beam – Function Testing
20.1
Initiate a closing cycle on the AGDO and as the Garage Door is closing pass your hand through the line of the
Safety Beams. If the Safety Beams are functioning correctly the AGDO should stop and then immediately
reverse direction.
20.2
If the Garage Door commences a close cycle but stops and reverses before the Safety Beams are blocked, check
that the Safety Beams are aligned correctly as outlined in points 18.1 ~ 18.3
21. Auto Close Mode
21.1
In Auto Close Mode the AGDO will automatically close a pre set time after it reaches the fully open position.
21.2
To enable Auto Close Mode move dip switch No.2 to the “ON” position. (Fig.1)
21.3
The Auto Close pre set time is determined by the position of dip switches Nos. 3 & 4 (Fig.1) and is set out in the
following table: 15 sec = Dip 3&4 Down b. 30 sec = Dip 3&4 Up
21.4
Important Note: Auto Close Mode will only work if Safety Beams have been enabled and correctly aligned
22. Output Terminals
22.1
The AGDO provides a 24VDC external power supply to support the connection of external accessories.
22.2
The values of the output terminals is set out in the following table: 9A ~ Com, 9B ~ Neg, 9C ~ +24VDC (Fig.1)
22.3
Important Note: For connection of any external accessory other than Safety Beams the jumper plug J8
located on the control board of the AGDO must be positioned so that the middle and left hand pins are
connected.
Содержание RDO-1BP
Страница 1: ...801 001 03 ...
Страница 4: ... 4 RDO1BP B OPERATING CONTROLS Fig 1 Fig 1A Fig 2 Fig 2A Fig 3 Fig 3A ...
Страница 16: ... 16 RDO1BP B CONTROL BOX MOUNTING TEMPLATE ...