background image

27

Printed in U.S.A. © 2013  Innovative Hearth Products LLC

P/N 900232-00, Rev. NC  12/2013

Innovative Hearth Products

1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210

Innovative Hearth Products

Superior™ Brand Wood-Burning Stove and Insert

5 Year Limited Warranty

THE WARRANTY

Innovative Hearth Products (“IHP”) 5 Year Limited Warranty warrants your Superior™ Brand wood stove or insert ("Product") to be free from defects in materials and work-

manship at the time of manufacture. The Product body, firebox, removable air tubes and ceramic glass carry the 5 Year Limited Warranty. Ceramic glass carries the 5 Year 

Limited Warranty against thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during 

the 5 Year Limited Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If 

repair or replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will 

also pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to one year. THERE ARE EXCLUSIONS AND 

LIMITATIONS to this 5 Year Limited Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of installation. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the 

date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This 5 Year Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed instruc-

tions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.

This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 

provided. The Product body and firebox carry the 5 Year Limited Warranty from the date of installation. Vent components, trim components and paint are excluded from this 

5 Year Limited Warranty. The following are warranted as follows:

Cast iron parts

 – Replacement for one year from the date of installation

Electrical components

 – Repair or replacement for one year from date of installation

Gaskets

 – Replacement for one year from the date of installation

Refractory & screens 

– Replacement for two years from date of installation. Excludes hairline cracks

Removable air tubes

 – Repair or replacement for five years from date of installation. IHP prevailing labor rates for one year from the date of installation.

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component, unless otherwise noted Parts not otherwise listed carry a 90 day war-

ranty from the date of installation.

Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance. (The Product must be subject to normal use with approved fuels listed in the Operation 

Manual provided with the product. Fuel products with abnormal burning characteristics, including but not limited to fuel such as driftwood, coal or plywood and wood products 

using a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly; IHP stoves and inserts are approved for 

burning dry seasoned wood only.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; 

(d) damages, repairs or inefficiency resulting from faulty installation or application of the Product.

Coverage of this 5 Year Limited Warranty is conditional upon the appliance being operated without the use of grates, irons or any other method to elevate the fire.

IHP is not responsible for inadequate system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction conditions which 

may generate negative air pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for smoking conditions caused by inadequate 

chimney height, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions.

This 5 Year Limited Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction which are not 

manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to any 

malfunction or defect in equipment are not covered by this 5 Year Limited Warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking 

IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, or 

in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.

In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after 

replacement or repair, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a particular 

use or purpose, and there is no implied condition of fitness for a particular use or purpose.

IHP makes no expressed warranties except as stated in this 5 Year Limited Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.

No one is authorized to change this 5 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces do 

not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this 5 Year Limited 

Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this 5 Year Limited Warranty and to decide, in its sole discretion, upon the method of settlement.

To receive the benefits and advantages described in this 5 Year Limited Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. 

IHP shall in no event be responsible for any warranty work done by a contrac-

tor that is not approved without first obtaining IHP's prior written consent.

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/

distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP 

Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.SUPERIORFIREPLACES.US.COM.

Содержание WXS2021WS

Страница 1: ...n faire la demande Num ro de la pi ce 900189 01 This appliance must be properly installed and operated in order to prevent the pos sibility of a house fire Please read this entire installation and ope...

Страница 2: ...Safety Information 3 Testing Information 4 Draft Requirements 4 Selecting the Proper Venting System 4 Negative Pressure Warning 5 Clearances to Combustibles 6 7 Floor Protection 6 Chimney and Connecto...

Страница 3: ...g season to check for soot and creosote accumulations Any accumulations over 1 8 thick should be removed by a professional chimney sweep Do not attempt to burn out heavy creosote accumulations with a...

Страница 4: ...e temperatures are reached beyond the design capabilities of the appliance The damage that occurs from overfiring is not covered under the manufacturer s limited warranty Also see Troubleshooting on P...

Страница 5: ...air is caused by many common household appliances which exhaust air from the home such as a furnace heat pump air conditioner clothes dryer exhaust fans fireplaces and other fuel burning appliances Al...

Страница 6: ...ed for mobile homes but connector pipe may be double wall single wall or single wall with shield as listed above This appliance may be vented into a code approved masonry chimney with flue liner WARNI...

Страница 7: ...bile Home 12 9 1 8 19 1 2 9 5 8 8 6 15 37 5 8 46 3 4 34 7 8 16 0 84 57 1 2 305 232 495 245 200 152 381 956 1188 886 406 0 2134 1461 CANADA inches millimeters PIPE INSTALLATION A 3 B 1 C 3 D 1 E 8 F 1...

Страница 8: ...ams illustrations and photographs are not to scale consult installa tion instructions Product designs materials dimensions specifications colors and prices are subject to change or discontinuance with...

Страница 9: ...6 Typical Installation Floor Protector Fasten each stove pipe connection with at least 3 sheet metal screws Single wall stove pipe must not pass through attics closets walls or ceilings It is used to...

Страница 10: ...ney and that it either be cemented to the masonry or be installed without cement in a thimble connected to the masonry wall When the connector is inserted into a thimble the joint must be tight enough...

Страница 11: ...n shall be 12 in 305 mm Chimney section concentric with and spaced 1 in 25 4 mm away from con nector by means of sheet steel support plates on both ends of chimney section Opening shall be covered and...

Страница 12: ...Duct length should be kept to a minimum b The air intake register must not be installed more than ten 10 feet 3050 mm above the base of the stove c The fresh air must come from outside the house The a...

Страница 13: ...be slightly smaller to adjust for steel and firebrick tolerances beyond our control Be sure to measure and mark bricks with their numbers when removing Warning If the bricks are not installed exactly...

Страница 14: ...oards are properly installed FOR YOUR OWN PROTECTION AND INSURANCE PURPOSES HAVE YOUR CHIMNEY AND CONNECTOR PIPE INSTALLATION INSPECTED BY YOUR LOCAL BUILDING CODE AUTHORITY OR FIRE MARSHAL BEFORE STA...

Страница 15: ...sed Operate only with the door shut tightly at all times except when loading wood and possibly on start up to establish a draft Never leave the unit unattended while the front door is opened 3 DO NOT...

Страница 16: ...iance it is important to become familiar with how the damper control affects heat output and the overall temperature of the appliance A stove thermom eter can be a helpful tool to help ensure you are...

Страница 17: ...lt in the release of toxic fumes This type of burning will also void your warranty Do Not store fuel within space heater installation clearances or within the space required for refueling and ash remo...

Страница 18: ...ou will need to have sufficient temperatures inside the firebox for thorough combustion The best method for determining if you have sufficient temperatures is to watch the brick lining in your firebox...

Страница 19: ...he stove is burned with the blower opening unobstructed Figure 24 The optional blower is controlled by a Dial a Temp see Figure 24 It contains an On Off line switch with variable speed control from lo...

Страница 20: ...aint DO Enjoy the warm feeling of your new IHP appliance Maintenance GLASS REPLACEMENT INSTRUCTIONS Refer to Figure 26 Step 1 Remove Door Assembly Remove the upper and lower hinge pins by pressing the...

Страница 21: ...or Latch Adjustment Instructions 1 Using a 5 32 hex wrench remove the side heat shield by removing 3 screws on the back 2 screws on the bottom and 1 screw at the top front corner 2 With the door open...

Страница 22: ...Pages 17 and 21 3 See Poor Draft section above and Cleaning Glass on Pages 4 and 21 SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OP...

Страница 23: ...ription H8890 Right side heat shield H8891 Left side heat shield H8892 Back heat shield H8893 Door back w pins H8894 Door channels w nuts H8895 Glass H5640 Glass gasket kit 8 4 H5639 Door rope kit 7 8...

Страница 24: ...ND UZI UZI Outside Air Ducting Kit includes 4 insulated flex x 10 long AND H8874 OUTAIRKIT ES Outside Air Panel and Air Channel Kit includes rear pedestal panel and side and front air channels MISC H8...

Страница 25: ...tielle Double Wall Double Parois Residential or Mobile Home PIPE INSTALLATION Single Wall Simple Paroi Residential R sidentielle Double Wall Double Parois Residential or Mobile Home THE ONE AND ONLY M...

Страница 26: ...26 NOTES...

Страница 27: ...e temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves and inserts are approved for burning dry seasoned wood only c damages caused by failing to provide...

Страница 28: ...wing information 1 The model number of the appliance 2 The Serial Number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the applian...