background image

16

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Place a small 

amount of 

crumpled paper 

in the front of the 

firebox

Cover paper with 

a few pieces of 

kindling

Light paper

Figure 19

Figure 20

DO NOT LEAVE THE STOVE UNATTENDED WHILE THE FRONT 
DOOR IS SLIGHTLY OPEN.

CAUTION: Do Not alter the adjustment range of the draft control 

for increased firing for any reason.

Operate only with fuel door closed. Maintain all seals in good 

condition. Do not operate with broken glass.

STARTING AND MAINTAINING A FIRE

1. 

NEVER USE FLAMMABLE LIqUIDS TO START OR REKINDLE 
A SOLID FUEL FIRE!!

2.  Fully open the primary draft control by placing draft control (wood 

handle located on left side of the stove) in the highest position.  This 

control determines the amount of air entering the stove.  Lowering 

this control reduces the burn rate of the stove.  

3.  Place a small amount of crumpled paper in the front of the firebox 

and cover it with a few pieces of kindling.

4.  Light the paper and allow sufficient time for the kindling to become 

fully engulfed in flames. You will now close the wood units front door.  

Your wood units front door may or may not need to be left slightly 

open during this start up process, this depends on the stove model 

and the amount of draft present. 

5.  When operating any wood burning appliance, it is important to 

become familiar with how the damper control affects heat output 

and the overall temperature of the appliance.  A stove thermom-

eter can be a helpful tool to help ensure you are not over-firing 

your appliance and it will also ensure you are burning fuel at a 

rate that is most efficient.  Place a stove thermometer on the top 

of the appliance as shown in Figure 19.  Monitor the temperature 

every 15 minutes or so until you become more familiar with your 

appliance.  Close the damper all the way down if you begin to 

reach 600 degrees, as this is a sign that you are operating your 

appliance at too high a temperature.

SEE MAINTENANCE SECTION FOR GLASS CLEANING GUIDELINES AND 
TIPS FOR KEEPING THE GLASS CLEAN (PAGE 21)
.

High

Low

Figure 21

6.  Once kindling is burning well, larger pieces of wood may be added, 

then the door should be fully closed if there was the need to keep it 

slightly open during start up.

7.  For best results, use smaller pieces of wood to get the stove or 

fireplace insert temperature very high before loading larger wood 

for sustained burns. If necessary, crack the door to allow ignition of 

the fuel charge. Now you can add larger pieces of wood and after 

several minutes of high burn, set the left control for the desired heat 

output. Check the exhaust in about 15 to 20 minutes 

(see 

Figure 22

)

Large amounts of smoke indicate an improper burn setting (either 

too high or too low). Adjust and recheck in 5 to 10 minutes.

Magnetic Thermometer 

(recommended)

Содержание WXS2021WS

Страница 1: ...n faire la demande Num ro de la pi ce 900189 01 This appliance must be properly installed and operated in order to prevent the pos sibility of a house fire Please read this entire installation and ope...

Страница 2: ...Safety Information 3 Testing Information 4 Draft Requirements 4 Selecting the Proper Venting System 4 Negative Pressure Warning 5 Clearances to Combustibles 6 7 Floor Protection 6 Chimney and Connecto...

Страница 3: ...g season to check for soot and creosote accumulations Any accumulations over 1 8 thick should be removed by a professional chimney sweep Do not attempt to burn out heavy creosote accumulations with a...

Страница 4: ...e temperatures are reached beyond the design capabilities of the appliance The damage that occurs from overfiring is not covered under the manufacturer s limited warranty Also see Troubleshooting on P...

Страница 5: ...air is caused by many common household appliances which exhaust air from the home such as a furnace heat pump air conditioner clothes dryer exhaust fans fireplaces and other fuel burning appliances Al...

Страница 6: ...ed for mobile homes but connector pipe may be double wall single wall or single wall with shield as listed above This appliance may be vented into a code approved masonry chimney with flue liner WARNI...

Страница 7: ...bile Home 12 9 1 8 19 1 2 9 5 8 8 6 15 37 5 8 46 3 4 34 7 8 16 0 84 57 1 2 305 232 495 245 200 152 381 956 1188 886 406 0 2134 1461 CANADA inches millimeters PIPE INSTALLATION A 3 B 1 C 3 D 1 E 8 F 1...

Страница 8: ...ams illustrations and photographs are not to scale consult installa tion instructions Product designs materials dimensions specifications colors and prices are subject to change or discontinuance with...

Страница 9: ...6 Typical Installation Floor Protector Fasten each stove pipe connection with at least 3 sheet metal screws Single wall stove pipe must not pass through attics closets walls or ceilings It is used to...

Страница 10: ...ney and that it either be cemented to the masonry or be installed without cement in a thimble connected to the masonry wall When the connector is inserted into a thimble the joint must be tight enough...

Страница 11: ...n shall be 12 in 305 mm Chimney section concentric with and spaced 1 in 25 4 mm away from con nector by means of sheet steel support plates on both ends of chimney section Opening shall be covered and...

Страница 12: ...Duct length should be kept to a minimum b The air intake register must not be installed more than ten 10 feet 3050 mm above the base of the stove c The fresh air must come from outside the house The a...

Страница 13: ...be slightly smaller to adjust for steel and firebrick tolerances beyond our control Be sure to measure and mark bricks with their numbers when removing Warning If the bricks are not installed exactly...

Страница 14: ...oards are properly installed FOR YOUR OWN PROTECTION AND INSURANCE PURPOSES HAVE YOUR CHIMNEY AND CONNECTOR PIPE INSTALLATION INSPECTED BY YOUR LOCAL BUILDING CODE AUTHORITY OR FIRE MARSHAL BEFORE STA...

Страница 15: ...sed Operate only with the door shut tightly at all times except when loading wood and possibly on start up to establish a draft Never leave the unit unattended while the front door is opened 3 DO NOT...

Страница 16: ...iance it is important to become familiar with how the damper control affects heat output and the overall temperature of the appliance A stove thermom eter can be a helpful tool to help ensure you are...

Страница 17: ...lt in the release of toxic fumes This type of burning will also void your warranty Do Not store fuel within space heater installation clearances or within the space required for refueling and ash remo...

Страница 18: ...ou will need to have sufficient temperatures inside the firebox for thorough combustion The best method for determining if you have sufficient temperatures is to watch the brick lining in your firebox...

Страница 19: ...he stove is burned with the blower opening unobstructed Figure 24 The optional blower is controlled by a Dial a Temp see Figure 24 It contains an On Off line switch with variable speed control from lo...

Страница 20: ...aint DO Enjoy the warm feeling of your new IHP appliance Maintenance GLASS REPLACEMENT INSTRUCTIONS Refer to Figure 26 Step 1 Remove Door Assembly Remove the upper and lower hinge pins by pressing the...

Страница 21: ...or Latch Adjustment Instructions 1 Using a 5 32 hex wrench remove the side heat shield by removing 3 screws on the back 2 screws on the bottom and 1 screw at the top front corner 2 With the door open...

Страница 22: ...Pages 17 and 21 3 See Poor Draft section above and Cleaning Glass on Pages 4 and 21 SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OP...

Страница 23: ...ription H8890 Right side heat shield H8891 Left side heat shield H8892 Back heat shield H8893 Door back w pins H8894 Door channels w nuts H8895 Glass H5640 Glass gasket kit 8 4 H5639 Door rope kit 7 8...

Страница 24: ...ND UZI UZI Outside Air Ducting Kit includes 4 insulated flex x 10 long AND H8874 OUTAIRKIT ES Outside Air Panel and Air Channel Kit includes rear pedestal panel and side and front air channels MISC H8...

Страница 25: ...tielle Double Wall Double Parois Residential or Mobile Home PIPE INSTALLATION Single Wall Simple Paroi Residential R sidentielle Double Wall Double Parois Residential or Mobile Home THE ONE AND ONLY M...

Страница 26: ...26 NOTES...

Страница 27: ...e temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves and inserts are approved for burning dry seasoned wood only c damages caused by failing to provide...

Страница 28: ...wing information 1 The model number of the appliance 2 The Serial Number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the applian...

Отзывы: