www.SuperiorFireplaces.US.com
127020-01A
7
Figure 6 - Lineal Gain
Hemmed
End
8" Stainless
Inner Pipe
12
3
/
8
" Galvanized
Outer Pipe
WARNING: The opening in
collar around chimney at top of
fireplace must not be obstruct
-
ed. Never use blown insulation
to fill chimney enclosure.
LINEAL GAIN
PART NO.
DESCRIPTION
GAIN
36"
Fireplace
40
"
12-8DM
12-8HT
Pipe Section
10
5
/
8
"
18-8DM
18-8HT
Pipe Section
16
5
/
8
"
24-8DM
24-8HT
Pipe Section
23
5
/
8
"
36-8DM
36-8HT
Pipe Section
34
5
/
8
"
48-8DM
48-8HT
Pipe Section
46
5
/
8
"
RT-8DM Round Termination
6
7
/
8
"*
RTL-8DM Round Termination
7
3
/
4
"*
RTT-8DM Round Termination
with Slip Section
6
7
/
8
" to
23
1
/
8
"*
RTTL-8DM Round Termination
with Slip Section
8
1
/
2
" to
21
1
/
2
"*
ET-8DM
Square Chase-Top
12
"*
ETO-8DM Square Chase-Top
with Mesh
12
"*
ETL-8DM Square Chase-Top
with Slip Section
7" to 15"*
ETLO-8DM
Square Chase-Top
with Mesh & Slip
Section
12
"
to
25
1
/
2
"*
* The lineal gain for the terminations is mea
-
sured to the flue gas outlet height.
VENTING INSTALLATION
Continued
CHIMNEY PIPE
The INNOVATIVE HEARTH PRODUCTS
chimney system consists of 12", 18", 24", 36"
and 48" snap-lock, double-wall pipe segments,
planned for maximum adaptability to individual
site requirements. Actual lengths gained after
fitting overlaps must be taken into consider
-
ation (lineal gain) and are given in the lineal
gain chart (see Figure 6). Lineal gain is the
actual measurable length of a part after two or
more parts are connected. For Canada, use
chimney parts designated "HT".
ASSEMBLY AND INSTALLATION OF
DOUBLE WALL CHIMNEY SYSTEM
Each double wall chimney section consists
of a galvanized outer pipe, a stainless steel
inner flue pipe and a wire spacer. The pipe
sections must be assembled independently
as the chimney is installed.
When connecting chimney directly to the
fireplace, the inner flue pipe section must
be installed first with the lanced side up.
The outer pipe section can then be installed
over the flue pipe section with the hemmed
end up. Press down on each pipe section
until the lances securely engage the hem
on the fireplace starter. The wire will assure
the proper spacing between the inner and
outer pipe sections. Continue to assemble
chimney sections as outlined, making sure
that both the inner and outer pipe sections are
locked together. When installing double wall
snap-lock chimney together, it is important to
assure the joint between the chimney sections
is locked. Check by pulling chimney upward
after locking. The chimney will not come apart
if properly locked. It is not necessary to add
screws to keep the chimney together (excep
-
tion - see Figure 9, page 10).