background image

www.SuperiorFireplaces.US.com

127020-01A

15

OPERATION AND MAINTENANCE GUIDELINES

Continued

Figure 22 - Damper and Air Kit Handle

OPE

N

CLOS

E

     

Handle

Outside Air 

Kit Handle

Keyway 

Slot

Handle 

Retainer

OUTSIDE AIR AND DAMPER 

HANDLE OPERATION

The damper handle, which opens and closes 

the damper blade, is located in the upper front 

face of the fireplace. Pushing the handle into 

the left of the keyway slot will free the damper 

blade  to  automatically  open.  Pushing  the 

handle  in  to  the  right  will  lock  the  damper 

blade closed (see Figure 22).
The outside air kit handle is located at the left 

hand  side  of  the  fireplace  (see  Figure  22). 

Pulling the handle out will free the outside air 

door to open. Pushing the handle in will lock 

the door closed. 

 WARNING: Risk of fire! Re

-

place  grate  with  INNOVATIVE 

HEARTH  PRODUCTS  model 

111028-01 only. This grate has 

been designed to keep the op

-

eration  of  your  fireplace  safe 

and efficient.

LOCATING ACCESS COVER PLATE

Sheet metal cover plates located underneath 

front hearth refractory may have shifted or moved 

out of place while fireplace was in transit. These 

cover plates must be kept in the proper location 

prior to using the fireplace (See Figure 23). 

For further operating guidelines, instruc

-

tions and warranty information, please re

-

fer to your homeowner's guide or contact 

your authorized dealer.

Figure 23 - Locating Access Cover Plate

Access 

Panel

TECHNICAL SERVICE

You may have further questions about instal

-

lation,  operation,  or  troubleshooting.  If  so, 

contact INNOVATIVE HEARTH PRODUCTS at 

 

1-800-655-2008.  When  calling  please  have 

your model and serial numbers of your heater 

ready.

You  can  also  visit  INNOVATIVE  HEARTH 

PRODUCTS’s web site at 

www.IHP.US.com

.

REPLACEMENT PARTS

If this product is missing a part or has a broken 

component, please do not return it to the store. 

Call INNOVATIVE HEARTH PRODUCTS at 

 

1-800-655-2008  to  answer  questions  and 

replace parts under warranty. 

Note: Use only original replacement parts. 

This will protect your warranty coverage for 

parts replaced under warranty.

When  calling  or  writing,  please  have  your 

model and serial numbers of your fireplace 

ready.
Model and serial number information are in the 

fireplace's rating plate located in the screen 

pocket to the left or right of the face opening. 

Содержание WRE3036WS

Страница 1: ...ly or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unles...

Страница 2: ...ife Refer to this manual for assistance or additional information Consultaqualifiedinstall er or local distributor IMPORTANT Check local codes before installing this fireplace Before beginning install...

Страница 3: ...0 TO TOP SPACERS NO COMBUSTIBLE MATERIAL ON FACE GAS LINE KNOCK OUTS AIR KIT KNOCK OUT GAS LINE KNOCK OUTS ELECTRICAL OUTLET LEFT SIDE RIGHT SIDE 9 125 11 435 14 437 41 250 37 41 35 21 8 32 5 14 25 2...

Страница 4: ...tion must allow for proper clear ances see Figures 1 and 2 2 Consider a location where the fireplace will not be affected by drafts air condition ing ducts windows or doors 3 A location that avoids th...

Страница 5: ...r of noncom bustible inorganic material having a thermal conductivity of K 0 84 BTU IN FT HR F or less at 1 thick For example if the material selected has a K factor of 0 25 such as glass fiber the fo...

Страница 6: ...outlet of the termination Figure 5 Outside Air Kit Secure to Collars with Metal Tape Screws or Straps Min of 1 4 x 20 in size Air Inlet Location Must Allow For Bushes or Snow Vent Hood Required for W...

Страница 7: ...s gained after fitting overlaps must be taken into consider ation lineal gain and are given in the lineal gain chart see Figure 6 Lineal gain is the actual measurable length of a part after two or mor...

Страница 8: ...ow Offset Elbow 6 Max 6 Max 6 Max 6 Max 6 Max 6 Max Return Elbow Offset Elbow Offset Elbow Return Elbow A B C Offset Elbow Ceiling Support Pipe 12S 8DM Return Elbow Figure 8 Ceiling Support Pipe 12S 8...

Страница 9: ...urpose is to establish and maintain the required clearance between the chimney and the combustible materials When the pipe passes through a framed opening into a living space above the firestop must b...

Страница 10: ...6 16 1 8 V6F 8DM 6 12 12 12 45 0 20 3 8 V12F 8DM FLASHING INSTALLATION V6F 8DM OR V12F 8DM Determine the flashing to be used with the roof opening chart Slide flashing over pipe until base is flat aga...

Страница 11: ...combination with the pipe assembly to achieve the correct chimney height Note In the rare instance there is a problem with the side driven rain or wind or the chim ney is not drafting properly an ADS...

Страница 12: ...terials do not overlap the face itself Brick glass tile or other noncombustible materials may overlap the front face provided they do not obstruct essential openings like louvered slots or any other o...

Страница 13: ...line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired CAUTION All gas piping andconnections mustbetested for l...

Страница 14: ...ck from the doors and never allow flames to contact the glass WARNING Fireplaces equipped with glass doors should be operated only with doorsfullyopenedordoorsfully closed Doors ifleftpartlyopen may d...

Страница 15: ...moved out of place while fireplace was in transit These cover plates must be kept in the proper location prior to using the fireplace See Figure 23 For further operating guidelines instruc tions and w...

Страница 16: ...laces US com 127020 01A 16 PARTS WOOD BURNING FIREPLACE MODELS WRE3036WS WRE3036WH WRE3036RS AND WRE3036RH 9 26 16 33 27 16 27 4 32 34 19 12 25 20 30 17 8 1 5 21 2 35 18 11 14 3 13 22 10 6 31 7 37 38...

Страница 17: ...ctor 1 21 111327 01 Fireplace Top Insulation 1 22 107775 01 Access Panel 1 23 107854 01 Right Refractory Bracket 1 24 107854 02 Left Refractory Bracket 1 25 111028 01 Grate 1 26 11418 Push On Nut 2 27...

Страница 18: ...actory Textured Red Herringbone 1 106659 01 Right Refractory Smooth White Brick 1 108165 01 Right Refractory Smooth White Herringbone 1 11 106660 03 Rear Refractory Textured White Brick 1 108166 03 Re...

Страница 19: ...FLASHING 0 TO 6 12 PITCH V6F 8DM 6 12 TO 12 12 PITCH V12F 8DM ANTI DRAFT SHIELD Round Top Termination Only ADS 8DM HOOD STAINLESS STEEL HS36 Required when installing a vent free gas log in this firep...

Страница 20: ...D RTL 8HT MESH ROUND TOP TERMINATIONS WITH SLIP SECTION RTT 8DM RTT 8HT RTTL 8DM AND RTTL 8HT ROUND TOP TERMINATIONS WITH LOUVERS RLT 8DM RLT 8HT ROUND TOP TERMINATIONS WITH LOUVERS WITH SLIP SECTION...

Страница 21: ...cannot ship via parcel delivery services IMPORTANT NOTICE A manufactured shroud which has been approved by a national testing agency for use with this fireplace may be used if installed in accordance...

Страница 22: ...rmal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning...

Страница 23: ...IS WARRANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ________________...

Страница 24: ...127020 01 Rev A 02 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P127020 01...

Страница 25: ...ted by local codes WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death AVERTISSEMENT Assurez vous d...

Страница 26: ...er control b Use of any component part not manufactured or approved by IHP in combination with an IHP fireplace system Proper installation is the most important step in ensuring safe and continuous op...

Страница 27: ...treat insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxide...

Страница 28: ...COMBUSTIBLE WALL BOARD TOP SPACERS 0 TO 1 AIRSPACE TO COMBUSTIBLE MATERIAL NO COMBUSTIBLE MATERIAL ON FACE NO COMBUSTIBLE MATERIAL BELOW TOP SPACERS GAS LINE KNOCK OUT AIR KIT KNOCK OUTS GAS LINE STA...

Страница 29: ...Height for Outdoor Installation The minimum height of the chimney measured from the base of the fireplace to the flue gas outlet of the termination is 8 feet minimum of 4 feet of chimney pipe sections...

Страница 30: ...f Combustible Materials Fireplace Opening Non Combustible Materials Below Top Spacer Upper Section of Fireplace DRAIN PAN DP42 For outdoor installations the fireplace enclosure must allow for adequate...

Страница 31: ...gained after fitting overlaps must be taken into consideration lineal gain and are given in lineal gain chart see Figure 6 Lineal gain is actual measurable length of a part after two or more parts are...

Страница 32: ...R 30 Offset return elbow A section or sections of chimney may be used between offsets and return elbow Transition pipe must be used after elbow offset is attached 1 To achieve desired offset you may i...

Страница 33: ...ntinued Figure 8 Typical Offset Installation 30E 8DM Return Elbow 30E 8DM Return Elbow 30E 8DM Offset Elbow 30E 8DM Offset Elbow 30E 12DMO 8DMR Offset Elbow 30E 12DMO 8DMR Offset Elbow 30E 12DMO 8DMR...

Страница 34: ...into a living space above firestop must be placed onto ceiling from below as shown in Figure 10 They also provide complete separation from one floor space to an other or attic space as required by mo...

Страница 35: ...aterial use only noncombustible mortar or adhesive Storm Collar Installation SC1 Place storm collar over pipe and slide down until it is snug against open edge of flashing see Figure 14 Use SC1 for al...

Страница 36: ...ne conduit sleeve if using a raised platform add height Provide sufficient gas line into fireplace chamber for fitting OPTIONAL GAS LINE INSTALLATION VENTING INSTALLATION Continued connection see Figu...

Страница 37: ...lass WARNING FIREPLACESEQUIPPEDWITHDOORS SHOULD BE OPERATED ONLY WITH DOORS FULLY OPENORDOORSFULLYCLOSED IFDOORSARELEFT PARTLYOPEN GASANDFLAMEMAYBEDRAWNOUT OF THE FIREPLACE OPENING CREATING RISKS OF B...

Страница 38: ...t These coverplatesmustbekeptintheproperlocationpriortousingthefireplace See Figure 23 For further operating guidelines instructions and warranty informa tion please refer to your homeowner s guide or...

Страница 39: ...Refractory Textured Red Herringbone 1 11 107816 03 Rear Refractory Textured White Brick 1 108171 03 Rear Refractory Textured White Herringbone 1 107816 02 Rear Refractory Textured Red Brick 1 108171...

Страница 40: ...27 4 32 34 19 12 25 20 30 17 8 1 5 21 2 35 18 11 14 3 13 22 10 6 39 31 7 37 38 36 28 29 24 23 15 PARTS WOOD BURNING FIREPLACE MODELS WRE3042WS WRE3042WH WRE3042RS WRE3042RH MODEL NO CATALOG NO WRE3042...

Страница 41: ...ge 15 Bottom Rear Refractory 1 13 See Page 15 Bottom Front Refractory 1 14 106683 01 Firebox Support Leg 4 15 Damper Can Collar 1 16 107839 01 Screen Rod 2 17 Firebox Top Assembly 1 18 106703 01 Air K...

Страница 42: ...SECTION RTT 8DM MESH ROUND TOP TERMINATIONS WITH SLIP SECTION RTTL 8DM ACCESSORIES DOUBLE WALL PIPE 12 8DM 12 8HT 18 8DM 18 8 HT 24 8DM 24 8HT 36 8DM 36 8HT 48 8DM 48 8HT ROOF FLASHING 0 TO 6 12 PITCH...

Страница 43: ...delivery services IMPORTANT NOTICE A manufactured shroud which has been approved by a national testing agency for use with this fireplace may be used if installed in accordance with the instruc tions...

Страница 44: ...n design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 127055 01 Rev D 10...

Отзывы: