Superior WCT3042RH Скачать руководство пользователя страница 3

Superiorfireplaces.US.com

126622-01D

3

SAFETY

 Continued

 WARNING: CONTINUED OVERFIRING CAN PER-

MANENTLY DAMAGE YOUR FIREPLACE SYSTEM. 

SOME EXAMPLES OF CONDITIONS THAT COULD 

CAUSE OVERFIRING ARE:

•  BURNING QUANTITIES OF SCRAP LUMBER, PINE 

BRANCHES,  PAPER  OR  CARDBOARD  BOXES 

WHICH EXCEED THE VOLUME OF THE NORMAL 

LOG FIRE.

•  BURNING TRASH, CHEMICALS OR CHEMICALLY 

TREATED COMBUSTIBLES.

"Disposal of Ashes 
Ashes should be placed in a metal container with a 

tight-fitting lid. The closed container of ashes should 

be placed on a noncombustible floor or on the ground, 

well away from all combustible materials, pending 

final disposal. If the ashes are disposed of by burial 

in soil or otherwise locally dispersed, they should be 

retained in the closed container until all cinders have 

thoroughly cooled."

"WHEN USING THE DECORATIVE APPLIANCE, THE 

FIREPLACE DAMPER MUST BE SET IN THE FULLY 

OPEN POSITION."

"Never use gasoline, gasoline-type lantern fuel, kero-

sene, charcoal lighter fluid, or similar liquids to start 

or ’freshen up’ a fire in this fireplace. Keep all such 

liquids well away from the fireplace while it is in use."

Use SOLID WOOD only for fuel. It is best to use dry 

and well seasoned hardwood. Softwoods tend to burn 

very quickly. DO NOT use treated wood, charcoal, coal, 

trash, driftwood or woods that have been dipped in tar, 

pitch, pine tar, creosote, etc. Wood products made 

with synthetic binders, such as plywood, produce ab-

normally high temperatures and sputtering, smoking 

fires.  When burning artificial logs, please read and 

follow the instructions provided by the manufacturer.

Never burn treated construction lumber or scraps. 

These woods burn excessively hot and may contain 

chemicals used to treat insects and fungus. When 

burned, these chemicals can pose a significant hazard.

 WARNING: BURNING IMPROPER FUEL (I.E. 

CHARCOAL) CAN RESULT IN CARBON MONOXIDE 

POISONING, WHICH MAY LEAD TO DEATH! 
Carbon Monoxide Poisoning – Early signs of carbon 

monoxide poisoning resemble the flu with headaches, 

dizziness, or nausea. If you have these signs, get 

fresh air at once!  Have the appliance inspected by a 

qualified service technician.  Some people are more 

affected by carbon monoxide than others.  These 

include pregnant women, people with heart or lung 

disease or anemia, those under the influence of al

-

cohol, and those at high altitudes.

Ventilation Requirements - Provide adequate air for 

combustion. The fresh air requirements of this ap-

pliance must be met within the space where it will 

be installed.

Smoke Detectors - Since there are always several 

potential sources of fire in any home, we recommend 

installing smoke detectors. If possible, install the 

smoke detector in a hallway adjacent to the room (to 

reduce the possibility of occasional false activation 

from the heat produced by the appliance).  If your local 

code requires a smoke detector be installed within the 

same room, you must follow the requirements of your 

local code. Check with your local building department 

for requirements in your area.

"Creosote – Formation and Need for Removal 

When wood is burned slowly, it produces tar and other 

organic vapors, which combine with expelled moisture 

to form creosote. The creosote vapors condense in 

the  relatively  cool  chimney  flue  of  a  slow-burning 

fire. As a result, creosote residue accumulates on 

the flue lining. When ignited this creosote makes an 

extremely hot fire. 

The chimney shall be inspected at least twice a 

year during the heating season to determine when a 

creosote buildup has occurred.  When creosote has 

accumulated (1/8" [3 mm] or more) it shall be removed 

to reduce the risk of a chimney fire."

Содержание WCT3042RH

Страница 1: ... a vented gas log approved to ANS Z21 60 Z21 84 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard An INNOVATIVE HEARTH PRODUCTS LLC hood must be installed when using a vent free log heater see Accessories page 18 This wood burning fireplace complies with UL127 CAN ULC S610 M87 standard as a FACTORY BUILT APPLIANCE FOR CANADA The authority having jurisdiction su...

Страница 2: ...rranty will be voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace components doors air inlet system and damper control b Use of any component part not manufactured or approved by IHP in combination with an IHP fireplace system Proper installation is the most important step in ensuring safe and continuous operation of the fireplace Consult the ...

Страница 3: ...o treat insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxide Poisoning Early signs of carbon monoxidepoisoningresemblethefluwithheadaches dizziness or nausea If you have these signs get fresh air at once Have the appliance inspected by a qualified service tec...

Страница 4: ... COMBUSTIBLE MATERIAL ON FACE NO COMBUSTIBLE MATERIAL BELOW TOP SPACERS GAS LINE KNOCK OUT AIR KIT KNOCK OUTS GAS LINE STARTER SECTION 8DM PIPE INNER DIA OUTER DIA 15 KNOCK OUTS ELECTRICAL OUTLET LEFT SIDE RIGHT SIDE PERPENDICULAR NOT LESS THAN 12 TO SIDEWALL 41 48 42 8 39 12 48 36 24 8 1 8 10 5 8 12 5 8 10 5 8 6 3 4 14 1 4 2 1 2 29 1 2 22 1 2 11 3 4 46 3 4 1 1 2 12 3 8 5 8 16 1 4 8 1 8 2 1 2 SQUA...

Страница 5: ... fireplace directly in front of this opening and slide unit back until nailing flanges touch side framing 4 Check level of fireplace and shim with sheet metal if necessary 5 Before securing fireplace to prepared framing ember protector must be placed between hearth extension not included and under bottom front edge of fireplace to protect against glowing embers falling through If fireplace is to b...

Страница 6: ...t be placed within 12 of fireplace opening and within 9 of top louver opening Combustible materials above 12 and projecting more than 1 1 2 from fireplace must not be placed less than 12 from top opening of fireplace NFPA 211 Section Clearance from Combustible Material Mantels or any other combustible material may come up to side edge of black metal face of fireplace if projection from front face ...

Страница 7: ...e Chassis Ground To Power Source Receptacle Supplied Power Source Wiring Not Supplied Prewired Receptacle and Ground Sheet Metal Screws Figure 8 Outside Air Kit Secure to Collars with Metal Tape Screws or Straps Min of 1 4 x 20 in size Air Inlet Location Must Allow For Bushes or Snow Vent Hood Required for Wall Installation Air Inlet Eyebrow Vented Crawl Space Check Local Codes Before Installing i...

Страница 8: ...with hemmed end up Press down on each pipe section until lances securely engage hem on fireplace starter Wire will assure proper spacing between inner and outer pipe sections Note For Canada use chimney parts designated HT Opening in collar around chimney at top of fireplace must not be obstructed Never use blown insulation to fill chimney enclosure Continue to assemble chimney sections as outline...

Страница 9: ...rt Pipe 12S 8DM VENTING INSTALLATION Continued 30E 8DM Return Elbow 30E 8DM Return Elbow 30E 8DM Offset Elbow 30E 8DM Offset Elbow 30E 12DMO 8DMR Offset Elbow 30E 12DMO 8DMR Offset Elbow 30E 12DMO 8DMR Offset Elbow 30E 12DMO 8DMR Return Elbow 30E 12DMO 8DMR Return Elbow 30E 12DMO 8DMR Return Elbow Starter Section Starter Section Starter Section 6 Max 8 DM Pipe 8 DM Pipe 6 Max 6 Max 6 Max 6 Max 6 M...

Страница 10: ...91 1 1 2 1 48 1 4 92 1 4 1 1 2 49 3 4 94 3 4 1 1 2 1 1 52 98 3 4 1 1 1 4 53 1 2 101 1 4 1 1 1 2 54 1 4 102 3 4 1 1 1 1 55 3 4 105 1 4 1 1 3 1 56 1 2 1061 2 1 1 1 2 58 3 4 110 1 2 1 1 2 2 59 1 2 111 3 4 1 1 1 1 1 60 1 4 113 1 1 2 61 3 4 115 3 4 1 1 1 1 2 64 3 4 120 3 4 1 1 2 2 65 1 2 122 1 4 1 1 1 2 67 124 3 4 1 1 2 1 2 Firestop spacers are required at each point where chimney penetrates a floor sp...

Страница 11: ...er with Attic Space Above Ceiling Figure 14a Firestop Thimble If area above is an attic or insulated area install firestop above framed hole PENETRATING ROOF To maintain a 1 clearance to pipe on a roof with a pitch a rectangular opening must be cut 1 Determine center point where pipe will penetrate the roof 2 Determine center point of the roof Pitch is the distance the roof drops over a given span...

Страница 12: ...g material use only noncombustible mortar or adhesive Storm Collar Installation SC1 Place storm collar over pipe and slide down until it is snug against open edge of flashing see Figure 17 Use SC1 for all round termina tions Apply waterproof caulk around perimeter of collar to provide a proper seal Figure 17 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing Terminations Spark Arrest...

Страница 13: ...ine conduit sleeve if using a raised platform add height OPTIONAL GAS LINE INSTALLATION 30E 12DMO 8DMR 30E 12DMO 8DMR 30E 12DMO 8DMR EFFECTIVE HEIGHT OF TERMINATION CAP EFFECTIVE HEIGHT OF TERMINATION CAP EFFECTIVE HEIGHT OF TERMINATION CAP EFFECTIVE HEIGHT OF TERMINATION CAP MINIMUM HEIGHT 14 1 2 FT 14 1 2 FT MINIMUM UP TO 6FT MAX UP TO 6FT MAX HEIGHT STARTER SECTION STARTER SECTION MIN HEIGHT OF...

Страница 14: ...OORSARELEFT PARTLYOPEN GASANDFLAMEMAYBEDRAWNOUT OF THE FIREPLACE OPENING CREATING RISKS OF BOTH FIRE AND SMOKE WARNING Discontinue use of the appliance imme diately if doors are damaged and contact a qualified installer for repair Only doors certified with the appliance shall be used WARNING Do not slam or strike doors Damage can result in a hazardous condition OPTIONAL GAS LINE INSTALLATION Conti...

Страница 15: ...arth refractory may have shifted or moved out of place while fireplace was in transit These coverplatesmustbekeptintheproperlocationpriortousingthefireplace See Figure 26 For further operating guidelines instructions and warranty informa tion please refer to your homeowner s guide or contact your dealer OPEN CLOSE Damper Handle Outside Air Kit Handle Keyway Slot Handle Retainer TECHNICAL SERVICE Y...

Страница 16: ...1 2 34 18 11 14 3 37 13 22 10 6 31 7 38 36 35 28 29 15 27 26 16 16 27 4 32 33 19 23 24 MODEL NO CATALOG NO WRT3042RS F0653 WRT3042RSI F0654 WRT3042RH F0655 WCT3042RS F0656 WCT3042RSI F0657 WCT3042RH F0658 WRT3042WS F0665 WRT3042WSI F0666 WRT3042WH F0667 WCT3042WS F0668 WCT3042WSI F0669 WCT3042WH F0670 ...

Страница 17: ... Page 18 Rear Refractory 1 12 See Page 18 Bottom Rear Refractory 1 13 See Page 18 Bottom Front Refractory 1 14 Firebox Support Leg 4 15 106687 02 Damper Can Collar 1 16 107839 01 Screen Rod 2 17 Firebox Top Assembly 1 18 Air Kit Door Assembly 1 19 Face Weldment 1 20 107823 01 Smoke Deflector 1 21 Fireplace Top Insulation 1 22 Access Panel 1 23 107854 01 Right Refractory Bracket 1 24 107854 02 Left...

Страница 18: ...2B Brushed Brass BD42P Platinum FAN KIT BK3 30 OFFSET AND RETURN 30E 8DM 30E 8HT 30E 12DMO 8DMR F1908 30E 12HTO 8HTR F2199 HERRINGBONE BRICK LINER WRT3042WH F0667 WCT3042WH F0670 Left 108169 01 Right 108170 01 Rear 108171 01 Bottom Rear 108172 01 Bottom Front 108173 01 WRT3042RH F0658 WCT3042RH F0655 Left 108169 02 Right 108170 02 Rear 108171 02 Bottom Rear 108172 02 Bottom Front 108173 02 STANDAR...

Страница 19: ... TOP TERMINATION WITH SLIP SECTION ETLO 8DM ACCESSORIES Continued OUTSIDE AIR KIT FOR FLOOR INSTALLATION AK4F MESH ROUND TOP TERMINATIONS RT 8DM TR 8HT RTL 8DM AND RTL 8HT 1 FIRESTOP SPACER 3600FS 8DM 1 OUTSIDE AIR KIT FOR SIDE WALL INSTALLATION AK4 BLOWER KIT BK MESH ROUND TOP TERMINATIONS WITH SLIP SECTION RTT 8DM RTT 8HT RTTL 8DM AND RTTL 8HT 38FST FIRESTOP THIMBLE 8 FST30 FIRESTOP THIMBLE 8 30...

Страница 20: ...in design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 126622 01 Rev D 10 2014 P126622 01 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 IHP US com ...

Отзывы: