background image

Superiorfireplaces.US.com

126622-01D

2

Safety .............................................................................................2

Specifications .................................................................................4

Fireplace Installation ......................................................................5

Venting Installation ........................................................................7

Optional Gas Line Installation ......................................................13

Operation and Maintenance .........................................................14

Replacement Parts .......................................................................15

Technical Service .........................................................................15

Parts ............................................................................................16

Accessories ..................................................................................18

Thank you for your purchase. We appreciate your 

business!

Please carefully read and follow all instructions in this manual. 

Pay 

special attention to all warnings and safety information.

Following these safety, care, and operation instructions will help 

ensure many years of dependable and enjoyable service from your 

fireplace.

Register your product online today!

To help us keep you up-to-date on product information and 

offers, please take a few moments to register your product on-

line at Superiorfireplaces.US.com 

(Owner Resources/Product 

Registration).

Please read and understand these instructions before installing 

or operating.

SAFETY

 WARNING: Improper installation, adjustment, 

alteration, service or maintenance can cause injury, 

property damage or loss of life. Refer to this manual 

for assistance or additional information. Consult a 

qualified installer or local distributor.

IMPORTANT: Check local codes before installing this 

fireplace.

Before beginning installation of this fireplace, read these instructions 

through completely.

•  This INNOVATIVE HEARTH PRODUCTS, LLC (IHP) fireplace and 

its components are safe when installed according to this installa-

tion manual. Unless you use IHP components, which have been 

designed and tested for the fireplace system, you may cause a fire 

hazard.

•  The IHP warranty will be voided by and IHP disclaims any respon

-

sibility for the following actions.

a. Modification of the fireplace, components, doors, air inlet 

system and damper control.
b. Use of any component part not manufactured or approved by 

IHP in combination with an IHP fireplace system.

Proper installation is the most important step in ensuring safe and 

continuous operation of the fireplace. Consult the local building codes 

as to the particular requirements concerned with the installation of 

all factory built fireplaces.

 WARNING: Do not install a fireplace insert in this 

fireplace unless the manufacturer's instructions with 

the insert specifically state this fireplace has been 

tested for use with this insert.

TABLE OF CONTENTS

FOR YOUR SAFETY

• Do not store or use gasoline or any other flammable 

vapors or liquids in the vicinity of this or any other 

appliance.

• Due to high temperatures, the appliance should be 

located out of traffic and away from furniture and 

draperies.

• Do not place clothing or other flammable materials 

on or near the appliance.

• Never  leave  children  unattended  when  a  fire  is 

burning in the fireplace.

 WARNING: Use solid wood or processed solid 

fuel fire logs only. "Do not poke or stir the logs while 

they are burning. Use only firelogs that have been 

evaluated for the application in fireplace and refer to 

firelog warnings and caution markings on packaging 

prior to use."

This fireplace is not intended to be used as a sub-

stitute for a furnace to heat an entire home. Use for 

supplemental heat only.

Ovefiring of a fireplace is a condition where exces-

sive temperatures are reached, beyond the design 

capabilities of the appliance. The damage that occurs 

from ovefiring is not covered under the manufacturer’s 

limited warranty.

Содержание WCT3042RH

Страница 1: ... a vented gas log approved to ANS Z21 60 Z21 84 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard An INNOVATIVE HEARTH PRODUCTS LLC hood must be installed when using a vent free log heater see Accessories page 18 This wood burning fireplace complies with UL127 CAN ULC S610 M87 standard as a FACTORY BUILT APPLIANCE FOR CANADA The authority having jurisdiction su...

Страница 2: ...rranty will be voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace components doors air inlet system and damper control b Use of any component part not manufactured or approved by IHP in combination with an IHP fireplace system Proper installation is the most important step in ensuring safe and continuous operation of the fireplace Consult the ...

Страница 3: ...o treat insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxide Poisoning Early signs of carbon monoxidepoisoningresemblethefluwithheadaches dizziness or nausea If you have these signs get fresh air at once Have the appliance inspected by a qualified service tec...

Страница 4: ... COMBUSTIBLE MATERIAL ON FACE NO COMBUSTIBLE MATERIAL BELOW TOP SPACERS GAS LINE KNOCK OUT AIR KIT KNOCK OUTS GAS LINE STARTER SECTION 8DM PIPE INNER DIA OUTER DIA 15 KNOCK OUTS ELECTRICAL OUTLET LEFT SIDE RIGHT SIDE PERPENDICULAR NOT LESS THAN 12 TO SIDEWALL 41 48 42 8 39 12 48 36 24 8 1 8 10 5 8 12 5 8 10 5 8 6 3 4 14 1 4 2 1 2 29 1 2 22 1 2 11 3 4 46 3 4 1 1 2 12 3 8 5 8 16 1 4 8 1 8 2 1 2 SQUA...

Страница 5: ... fireplace directly in front of this opening and slide unit back until nailing flanges touch side framing 4 Check level of fireplace and shim with sheet metal if necessary 5 Before securing fireplace to prepared framing ember protector must be placed between hearth extension not included and under bottom front edge of fireplace to protect against glowing embers falling through If fireplace is to b...

Страница 6: ...t be placed within 12 of fireplace opening and within 9 of top louver opening Combustible materials above 12 and projecting more than 1 1 2 from fireplace must not be placed less than 12 from top opening of fireplace NFPA 211 Section Clearance from Combustible Material Mantels or any other combustible material may come up to side edge of black metal face of fireplace if projection from front face ...

Страница 7: ...e Chassis Ground To Power Source Receptacle Supplied Power Source Wiring Not Supplied Prewired Receptacle and Ground Sheet Metal Screws Figure 8 Outside Air Kit Secure to Collars with Metal Tape Screws or Straps Min of 1 4 x 20 in size Air Inlet Location Must Allow For Bushes or Snow Vent Hood Required for Wall Installation Air Inlet Eyebrow Vented Crawl Space Check Local Codes Before Installing i...

Страница 8: ...with hemmed end up Press down on each pipe section until lances securely engage hem on fireplace starter Wire will assure proper spacing between inner and outer pipe sections Note For Canada use chimney parts designated HT Opening in collar around chimney at top of fireplace must not be obstructed Never use blown insulation to fill chimney enclosure Continue to assemble chimney sections as outline...

Страница 9: ...rt Pipe 12S 8DM VENTING INSTALLATION Continued 30E 8DM Return Elbow 30E 8DM Return Elbow 30E 8DM Offset Elbow 30E 8DM Offset Elbow 30E 12DMO 8DMR Offset Elbow 30E 12DMO 8DMR Offset Elbow 30E 12DMO 8DMR Offset Elbow 30E 12DMO 8DMR Return Elbow 30E 12DMO 8DMR Return Elbow 30E 12DMO 8DMR Return Elbow Starter Section Starter Section Starter Section 6 Max 8 DM Pipe 8 DM Pipe 6 Max 6 Max 6 Max 6 Max 6 M...

Страница 10: ...91 1 1 2 1 48 1 4 92 1 4 1 1 2 49 3 4 94 3 4 1 1 2 1 1 52 98 3 4 1 1 1 4 53 1 2 101 1 4 1 1 1 2 54 1 4 102 3 4 1 1 1 1 55 3 4 105 1 4 1 1 3 1 56 1 2 1061 2 1 1 1 2 58 3 4 110 1 2 1 1 2 2 59 1 2 111 3 4 1 1 1 1 1 60 1 4 113 1 1 2 61 3 4 115 3 4 1 1 1 1 2 64 3 4 120 3 4 1 1 2 2 65 1 2 122 1 4 1 1 1 2 67 124 3 4 1 1 2 1 2 Firestop spacers are required at each point where chimney penetrates a floor sp...

Страница 11: ...er with Attic Space Above Ceiling Figure 14a Firestop Thimble If area above is an attic or insulated area install firestop above framed hole PENETRATING ROOF To maintain a 1 clearance to pipe on a roof with a pitch a rectangular opening must be cut 1 Determine center point where pipe will penetrate the roof 2 Determine center point of the roof Pitch is the distance the roof drops over a given span...

Страница 12: ...g material use only noncombustible mortar or adhesive Storm Collar Installation SC1 Place storm collar over pipe and slide down until it is snug against open edge of flashing see Figure 17 Use SC1 for all round termina tions Apply waterproof caulk around perimeter of collar to provide a proper seal Figure 17 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing Terminations Spark Arrest...

Страница 13: ...ine conduit sleeve if using a raised platform add height OPTIONAL GAS LINE INSTALLATION 30E 12DMO 8DMR 30E 12DMO 8DMR 30E 12DMO 8DMR EFFECTIVE HEIGHT OF TERMINATION CAP EFFECTIVE HEIGHT OF TERMINATION CAP EFFECTIVE HEIGHT OF TERMINATION CAP EFFECTIVE HEIGHT OF TERMINATION CAP MINIMUM HEIGHT 14 1 2 FT 14 1 2 FT MINIMUM UP TO 6FT MAX UP TO 6FT MAX HEIGHT STARTER SECTION STARTER SECTION MIN HEIGHT OF...

Страница 14: ...OORSARELEFT PARTLYOPEN GASANDFLAMEMAYBEDRAWNOUT OF THE FIREPLACE OPENING CREATING RISKS OF BOTH FIRE AND SMOKE WARNING Discontinue use of the appliance imme diately if doors are damaged and contact a qualified installer for repair Only doors certified with the appliance shall be used WARNING Do not slam or strike doors Damage can result in a hazardous condition OPTIONAL GAS LINE INSTALLATION Conti...

Страница 15: ...arth refractory may have shifted or moved out of place while fireplace was in transit These coverplatesmustbekeptintheproperlocationpriortousingthefireplace See Figure 26 For further operating guidelines instructions and warranty informa tion please refer to your homeowner s guide or contact your dealer OPEN CLOSE Damper Handle Outside Air Kit Handle Keyway Slot Handle Retainer TECHNICAL SERVICE Y...

Страница 16: ...1 2 34 18 11 14 3 37 13 22 10 6 31 7 38 36 35 28 29 15 27 26 16 16 27 4 32 33 19 23 24 MODEL NO CATALOG NO WRT3042RS F0653 WRT3042RSI F0654 WRT3042RH F0655 WCT3042RS F0656 WCT3042RSI F0657 WCT3042RH F0658 WRT3042WS F0665 WRT3042WSI F0666 WRT3042WH F0667 WCT3042WS F0668 WCT3042WSI F0669 WCT3042WH F0670 ...

Страница 17: ... Page 18 Rear Refractory 1 12 See Page 18 Bottom Rear Refractory 1 13 See Page 18 Bottom Front Refractory 1 14 Firebox Support Leg 4 15 106687 02 Damper Can Collar 1 16 107839 01 Screen Rod 2 17 Firebox Top Assembly 1 18 Air Kit Door Assembly 1 19 Face Weldment 1 20 107823 01 Smoke Deflector 1 21 Fireplace Top Insulation 1 22 Access Panel 1 23 107854 01 Right Refractory Bracket 1 24 107854 02 Left...

Страница 18: ...2B Brushed Brass BD42P Platinum FAN KIT BK3 30 OFFSET AND RETURN 30E 8DM 30E 8HT 30E 12DMO 8DMR F1908 30E 12HTO 8HTR F2199 HERRINGBONE BRICK LINER WRT3042WH F0667 WCT3042WH F0670 Left 108169 01 Right 108170 01 Rear 108171 01 Bottom Rear 108172 01 Bottom Front 108173 01 WRT3042RH F0658 WCT3042RH F0655 Left 108169 02 Right 108170 02 Rear 108171 02 Bottom Rear 108172 02 Bottom Front 108173 02 STANDAR...

Страница 19: ... TOP TERMINATION WITH SLIP SECTION ETLO 8DM ACCESSORIES Continued OUTSIDE AIR KIT FOR FLOOR INSTALLATION AK4F MESH ROUND TOP TERMINATIONS RT 8DM TR 8HT RTL 8DM AND RTL 8HT 1 FIRESTOP SPACER 3600FS 8DM 1 OUTSIDE AIR KIT FOR SIDE WALL INSTALLATION AK4 BLOWER KIT BK MESH ROUND TOP TERMINATIONS WITH SLIP SECTION RTT 8DM RTT 8HT RTTL 8DM AND RTTL 8HT 38FST FIRESTOP THIMBLE 8 FST30 FIRESTOP THIMBLE 8 30...

Страница 20: ...in design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 126622 01 Rev D 10 2014 P126622 01 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 IHP US com ...

Отзывы: