INSTALLATION

 WARNING: A qualified service person must install 

firebox. Follow all local codes.

 WARNING: Never install firebox

• in a bedroom or bathroom*

• in a recreational vehicle

• where curtains, furniture, clothing, or other flam-

mable objects are less than 36" from front or 42" 

from top of firebox; for side clearances see Figure 

4, page 8

• in high traffic areas

• in windy or drafty areas
* Unless installed log set is rated at 10,000 Btu/Hr or 

less, 6,000 for bathrooms

 CAUTION: Log heaters installed in this firebox cre-

ate warm air currents. These currents move heat to 

wall surfaces next to firebox. Installing firebox next to 

vinyl or cloth wall coverings or operating firebox where 

impurities (such as, but not limited to, tobacco smoke, 

aromatic candles, cleaning fluids, oil or kerosene lamps, 

etc.) in the air exist, may discolor walls or cause odors.

NOTICE: The firebox identification label (including 

model number, serial number, clearances, etc.) is 

located on a chain under the bottom refractory.

IMPORTANT: Vent-free gas log heaters add moisture to the air. Al-

though this is beneficial, installing firebox in rooms without enough 

ventilation air may cause mildew to form from too much moisture. 

See, page 7.
IMPORTANT: Make sure the firebox is level. If firebox is not level, log 

set will not work properly.
Note: Your firebox is designed to be used in zero clearance instal-

lations. Wall or framing material can be placed against any exterior 

surface on the rear, sides, top or bottom of your firebox, except 

where standoff spacers are integrally attached. If standoff spacers 

are attached to your firebox, these spacers can be placed directly 

against wall or framing materials. Use the dimensions shown for 

rough opening to create the easiest installation.
Use dimensions shown for rough openings to create the easiest 

installation (see Built-In Firebox Installation, page 10).

INSTALLATION CLEARANCES

 WARNING: Maintain the minimum clearances. If 

you can, provide greater clearances from floor, ceil-

ing, and adjoining wall.

Carefully follow the instructions below. This will ensure safe instal-

lation.

Minimum Wall and Ceiling Clearances (see Figure 6)
A.

  Clearances from the side of the fireplace cabinet to any combus-

tible material and wall should follow diagram in Figure 6.

  Example: The face of a mantel, bookshelf, etc. is made of combus-

tible material and protrudes 3 

1

/

2

" from the wall. This combustible 

material must be 4" from the side of the fireplace cabinet (see 

Figure 4, page 8).

B.

  Clearances from the top of the firebox opening to the ceiling should 

not be less than 42".

C.

  When the firebox is installed directly on carpeting, tile or other 

combustible material, other than wood flooring, the firebox should 

be installed on a metal or wood panel extending the full width and 

depth of the enclosure.

D.  Clearances from the bottom of firebox to the floor is 0".

These fireboxes can be installed as freestanding units against a 

wall with approved cabinet mantels that may be available from your 

retailer or supplier, or as a built-in unit. The clearances are the same 

for either installation method.

Figure 6 - Minimum Clearance for Combustible to Wall

*Minimum 16" from Side Wall 

Example

*

Содержание VRE6000 Series

Страница 1: ...n this manual for future reference WARNING Carefully review the instructions supplied with the decorative type unvented room heater for the minimum fireplace size requirement DO NOT INSTALL THE APPLIANCE IN THIS FIREBOX UNLESS THIS FIREBOX MEETS THE MINIMUM DIMEN SIONS REQUIRED FOR THE INSTALLATION WARNING Improper installation adjustment alteration service or maintenance can cause injury or prope...

Страница 2: ...nd completely before trying to assemble operate or service this fireplace Improper use of this fireplace can cause serious injury or death from burns fire explosion electrical shock and carbon monoxide poisoning DANGER Carbon monoxide poisoning may lead to death WARNING Anychangetothisfireboxoritscontrols can be dangerous WARNING Do not allow fans to blow directly into the firebox Avoid any drafts...

Страница 3: ...proved ANSI Z21 11 2 deco rative type unvented room heaters Physical size limitations apply Refer to minimum firebox requirements supplied with log heater It requires no outside venting or chimney making installation easy and inexpensive State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natur...

Страница 4: ...1B 4 PRODUCT SPECIFICATIONS 36 MODELS Figure 1 36 Models VRE6036RS VRE6036IS VRE6036RH and VRE6036IH 30 1 2 29 30 11 1 8 54 1 2 7 7 8 7 36 45 1 8 35 16 97 16 50 365 16 7 3 8 111 8 3 3 4 4 7 8 36 HEARTH 1 1 4 20 1 4 Ref 35 1 4 19 22 1 2 ...

Страница 5: ...ODUCT SPECIFICATIONS continued 42 MODELS Figure 2 42 Models VRE6042RS VRE6042IS VRE6042RH and VRE6042IH 4 7 8 54 1 2 7 7 8 7 36 5 16 50 42 51 1 8 32 3 8 3 3 4 30 5 16 8 3 4 13 3 5 16 9 7 16 30 11 1 8 42 HEARTH 1 1 4 23 Ref 41 3 8 26 3 8 21 3 4 ...

Страница 6: ...igure 3 50 Models VRE6050RS VRE6050IS VRE6050RH and VRE6050IH 365 16 50 8 3 4 13 35 16 97 16 59 1 8 50 7 7 8 7 30 54 1 2 11 1 8 32 3 8 3 3 4 38 5 16 4 7 8 50 HEARTH 1 1 4 23 Ref 49 3 8 34 3 8 21 3 4 PRODUCT SPECIFICATIONS continued 50 MODELS ...

Страница 7: ...ia above you must provide ad ditional fresh air See Ventilation Air From Outdoors page 8 If your home does not meet all of the three criteria above proceed to Determining Fresh Air Flow For Firebox Location Confined and Unconfined Space TheNational Fuel Gas Code ANSI Z223 1 NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of t...

Страница 8: ...ined space When ventilating to an adjoining unconfined space you must provide two permanent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see options 1 and 2 Figure 4 You can also remove door into adjoining room see option 3 Figure 4 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required siz...

Страница 9: ... bottom of your firebox except where standoff spacers are integrally attached If standoff spacers are attached to your firebox these spacers can be placed directly against wall or framing materials Use the dimensions shown for rough opening to create the easiest installation Use dimensions shown for rough openings to create the easiest installation see Built In Firebox Installation page 10 INSTALL...

Страница 10: ...al product standard Fol low all minimum clearances shown in this manual NOTICE Ifyourinstallationdoesnotmeettheminimum clearances shown you must do one of the following raise the mantel to an acceptable height remove the mantel BUILT IN FIREBOX INSTALLATION Built in installation of this firebox involves installing firebox into a framed in enclosure This makes the front of firebox flush with wall I...

Страница 11: ...des This firebox may be installed using a cabinet mantel against a wall in your home The firebox and cabinet mantel can be installed directly on the floor Mantels may be available from your retailer or custom built for your home 1 Assemble cabinet mantel as instructed 2 Install gas piping to firebox location See Gas Line Installation on page 13 You may have to cut an access hole in the floor or wa...

Страница 12: ...ight Face Slot Figure 14 Slots for Firebrick Walls Figure 15 Installing Side Walls Retaining Bracket Figure 13 Removing Shipping Brackets GROUTING INSTRUCTIONS Material provided Bag of cement Bag of sand Material required Piping bag Joints striker Heavy duty mixing bucket Sponge or Wet Cloth 1 Moisten brick surface with damp sponge or spray bottle just prior to application When bricks are wet any ...

Страница 13: ...replace chamber for fitting connection see Figure 19 Note Secureincominggaslinetowoodframingtoproviderigidityfor threaded end 4 Repack insulation around gas line and into sleeve opening Seal any gaps between gas line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired A gas line or gas log lighter may be installe...

Страница 14: ...Superiorfireplaces US com 127026 01B 14 11 10 11 13 14 15 16 14 3 22 20 21 20 1 19 5 14 15 16 13 12 11 9 7 6 8 17 2 12 18 4 PARTS 36 42 AND 50 SUPERIOR MODELS ...

Страница 15: ...s Conduit Cover 4 15 109752 01 Conduit One 2 16 109752 02 Conduit Two 2 17 Heat Shield Support 1 18 123298 02 Ash Box Assembly 1 19 Firebox Top 1 20 109457 03 Screen 36 2 109457 02 Screen 42 2 109457 01 Screen 50 2 117556 03 Screen 36 Stainless 2 117556 02 Screen 42 Stainless 2 117556 01 Screen 50 Stainless 2 21 20806 Screen Rod 36 2 110146 03 Screen Rod 42 2 110146 02 Screen Rod 50 2 117568 03 Sc...

Страница 16: ...7 7 8 PARTS 36 42 AND 50 SUPERIOR MODELS Picture may vary from actual WARNING Contact an IHP dealer to obtain any of these parts Never use substitute materials not approved by IHP Use of non approved parts can result in poor performance and safety hazards ...

Страница 17: ...tacked 42 Red 1 125429 01 Left Herringbone 42 Red 1 125441 01 Left Stacked 50 Red 1 125453 01 Left Herringbone 50 Red 1 7 125556 01 Panel Retainers 3 8 120848 01 Ash Brick Red 1 KEY NO PART NO DESCRIPTION VRE6036IS F0462 VRE6036IH F0464 VRE6042IS F0466 VRE6042IH F0468 VRE6050IS F0470 VRE6050IH F0472 QTY 1 125116 03 Left Leading Brick 36 Ivory 1 125118 03 Left Leading Brick 42 50 Ivory 1 2 125116 0...

Страница 18: ...n component please do not return it to the store Call INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 to answer questions and replace parts under warranty Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty When calling or writing please have your model and serial numbers of your fireplace ready Model and serial number information are in...

Страница 19: ... to burn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damages repairs or inefficiency resulting from fau...

Страница 20: ..._ Keep receipt for warranty verification Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2014 IHP LLC P N 127026 01 Rev B 01 2015 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 I...

Отзывы: