CLEANING AND MAINTENANCE

INSPECTING BURNERS

 WARNING: Turn off fireplace and let cool before 

cleaning.

 CAUTION: You must keep control areas, burner 

and circulating air passageways of fireplace clean. 

Inspect these areas of fireplace before each use. Have 

fireplace inspected yearly by a qualified service person. 

 WARNING: Failure to keep the primary air 

opening(s) of the burner(s) clean may result in sooting 

and property damage.

BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with 

the gas. This provides a clean burning flame. Keep these holes clear 

of dust, dirt, lint and pet hair. Clean these air inlet holes prior to each 

heating season. Blocked air holes will create soot. We recommend 

that you clean the unit every three months during operation and have 

fireplace inspected yearly by a qualified service person.
We also recommend that you keep the burner tube and pilot assembly 

clean and free of dust and dirt. To clean these parts we recommend 

using compressed air no greater than 30 PSI. Your local computer 

store, hardware store or home center may carry compressed air in 

a can. If using compressed air in a can, please follow the directions 

on the can. If you don’t follow directions on the can, you could dam

-

age the ignitor.
1.  Shut off the unit. Allow the unit to cool for at least thirty minutes.
2.  Inspect burner, air shutter and orifice for dust and dirt (see Figure 

30).

3.  Blow air through the ports/slots and holes in the burner.
4.  Check the orifice located at the end of the burner tube again. Remove 

any large particles of dust, dirt, lint or pet hair with a soft cloth or 

vacuum cleaner nozzle.

5.  Blow air into the primary air holes on the injector holder.
6.  In case any large clumps of dust have now been pushed into the 

burner repeat steps 3 and 4 above.

BURNER PRIMARY AIR HOLES

Air is drawn into the burner through the holes in the fitting at the 

burner entrance. These holes may become blocked with dust or lint. 

Periodically inspect these holes for any blockage and clean if needed. 

Blocked air holes will create soot.

MAIN BURNER

Periodically inspect all burner flame holes with the fireplace running. 

Some burner flame holes may become blocked by debris or rust, with 

no flame present. If so, turn off fireplace and let cool. Remove blockage. 

Blocked burner flame holes will create soot. 

BURNER FLAME PATTERN

 WARNING: If yellow tipping occurs, your fireplace 

could produce increased levels of carbon monoxide.

NOTICE: Do not mistake orange flames with yellow 

tipping. Dirt or other fine particles enter the fireplace 

and burn causing brief patches of orange flame. 

Burner flames will be steady, not lifting or floating. Flame patterns will 

be different from unit to unit and will vary depending on installation 

type and weather conditions.  This can be dangerous. Inspect flames 

after installation to ensure proper installation and performance.
If burner flame pattern differs from that described:

•  turn fireplace off (see 

To Turn Off Gas to Appliance, page 14) 

•  see 

Troubleshooting, page 17

REPLACING LIGHT BULB

Light assembly is located underneath the burner assembly (see page 

24 for reference).
1.  Unplug power supply.
2.  Remove access door (Figure 22, page 12).
3.  Remove glass panel if installed (Figure 25, page 13).
4.  Remove rear interior panels (Figure 19, page 11).
5.  Remove glass Pebbles.
6.  Remove six screws holding the pebble pan (see item #17 on 

page 22 for reference).

7.  Using a small slotted screw driver, carefully slide it under the 

edge of light bulb cover and pry it open. Pull burned out bulb 

and replace.

8.  Replace all in reverse order.

Figure 30 - Injector Holder On Outlet Burner Tube

Burner

Ports/Slots

Venturi

Air Shutter

Содержание VRE4543

Страница 1: ...uivre les instructions donn es dans cette notice pour r duire au minimum le risque d incindie ou d explosion ou pour viter tout dommage mat riel toute blessure ou la mort Do not store or use gasoline...

Страница 2: ...y be present even though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this fireplace WARNING Any cha...

Страница 3: ...box or on adjacent walls or furniture 8 Do not run fireplace where flammable liquids or vapors are used or stored under dusty conditions SAFETY Continued 9 Do not use this fireplace to cook food or b...

Страница 4: ...Flange Access Door Top Spacers PRODUCT FEATURES OPERATION This fireplace is clean burning It requires no outside venting There is no heat loss out a vent or up a chimney Heat is generated by realistic...

Страница 5: ...e mantels may discolor INSTALLATION Continued Figure 2 Framing Clearances for One Sided Application Figure 3 Framing Clearances for See Thru Application 17 50 53 25 38 15 25 53 25 38 17 50 53 25 38 Fi...

Страница 6: ...6 INSTALLATION Continued Figure 6 VRE4543E Series Dimensions 11 13 16 16 1 2 17 1 2 5 8 29 13 16 8 1 4 1 55 1 16 52 47 44 1 16 29 25 32 7 1 32 16 9 32 2 716 1 816 8 255 13 217 1 816 3 208 Gas Line Acc...

Страница 7: ...Aqualifiedservicepersonmustconnect fireplace to gas supply Follow all local codes CAUTION Never connect propane LP fireplace di rectly to the propane LP supply This fireplace requires an external reg...

Страница 8: ...s This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged fireplace valves Never use sealant on flare threads WARNING Use pipe joint sealant that is resist...

Страница 9: ...alve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Figure 11 2 Pressurize supply piping system by either...

Страница 10: ...rd mounting bracket and replace screws FINISHING FIREPLACE FOR INSTALLATION The VRE4543 series fireplace come with the rear panel semi installed If you will be using the fireplace for a one sided regu...

Страница 11: ...r Figure 20 Installing Access Door Retaining Brackets for See Thru Applications Figure 21 Installing Side Face Filler for See Thru Applications Removing Rear Interior Wall 1 Through firebox opening in...

Страница 12: ...the electronic access cover See Figure 23 3 Remove electronic access cover by gently pulling up and out of the fireplace There are two switches connected to cover 4 The control module is located on t...

Страница 13: ...shield that is covering the module and remove the screw on top Use a small thin object like a paper clip not sharp points to press and release the learn button There will be a beep sound from the mod...

Страница 14: ...1 STOP Read the safety information column 1 2 Make sure equipment shutoff valve is fully open 3 Turn safety shutoff switch to the OFF position 4 Remove access cover 5 Turn equipment shutoff valve cloc...

Страница 15: ...any large clumps of dust have now been pushed into the burner repeat steps 3 and 4 above BURNER PRIMARY AIR HOLES Air is drawn into the burner through the holes in the fitting at the burner entrance...

Страница 16: ...Orange Red Brown Black Solenoid White Brown Brown Green Ignitor Pilot I S AUX AF 5000MOD AF 4000 AF 4000B P Control Module Black Black SWI SWI GND Red HI LO Main Black BATTERY PACK Black Red Black Re...

Страница 17: ...losed 2 Air in gas lines when installed 3 Depleted gas supply propane LP only 4 Control module not in REMOTE position 5 Gas control valve pressure setting is not correct 6 Inlet gas pressure is too lo...

Страница 18: ...tor assembly is relighting the burner 4 Wire connection loose or wire broken REMEDY 1 Contact local natural or propane LP gas company 2 Clean burner see Cleaning and Main tenance page 18 or replace bu...

Страница 19: ...every one second Gas odor during combustion POSSIBLE CAUSE 1 Appliance burning vapors from paint hair spray glues cleaners chemicals new carpet etc See IMPORTANT statement above 2 Low fuel supply prop...

Страница 20: ...SuperiorFireplaces US com 127035 01C 20 PARTS MODELS VRE4543EN AND VRE4543EP 1 2 4 4 4 4 5 8 6 7 3 9 10 11 19 20 21 12 12 13 14 4 22 15 16 18 17...

Страница 21: ...399 Brass Elbow 2 11 111817 01 Flextube 1 12 125932 01 Burner Gasket 2 13 126050 02 Electronic Access Cover LVFO 1 14 126051 01 Insulation Heat Shield 1 15 125976 02 Bracket Valve Components 1 16 1460...

Страница 22: ...5768 03 Access Door Stainless 1 13 125766 02 Side Face Filler Stainless 2 14 125975 02 Fireplace Hood Stainless 1 15 126399 01 Glass tempered 1 16 126397 01 Bracket Glass Retainer 2 17 125753 02 Pebbl...

Страница 23: ...ified heat for propane LP unit propane LP gas supply may be low You may feel your gas pressure is too low If so contact your local gas supplier TECHNICAL SERVICE You may have further questions about i...

Страница 24: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 25: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 26: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 27: ...to burn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in...

Страница 28: ...ns pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2014 IHP LLC P N 127035 01 Rev C 04 2015 P127035 01 1508 Elm Hill P...

Отзывы: