background image

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.

WHEN USED AS AN OUTDOOR APPLIANCE

DANGER

CARBON MONOXIDE WARNING

• 

This appliance can produce 

carbon monoxide which has 

no odor.

• 

Using it in an enclosed 

space can kill you.

• 

Never use this appliance in 

an enclosed space such as 

a camper, tent, car or home.

 

WARNING: For Outdoor Use Only.

 

DANGER

IF YOU SMELL GAS:

1.  Shut off gas to appliance.

2.  Extinguish any open flame.

3.  If odor continues, keep away from the appli-

ance and immediately call your gas supplier 

or fire department. 

 

WARNING: Do not store gasoline or other flammable vapors and liquids in the vicinity of this or any 

other appliance. An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other 

appliance.

 WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or 

property damage. Read the installation, operating and maintenance instructions thoroughly before install-

ing or servicing this equipment.

WARNING: If the information in these 

instructions is not followed exactly, a fire or 

explosion may result causing property damage, 

personal injury or death.

AVERTISSEMENT : Assurez-vous de bien suivre les 

instructions données dans cette notice pour réduire au 

minimum le risque d’incindie ou d’explosion ou pour éviter 

tout dommage matériel, toute blessure ou la mort.

 

 Do not store or use gasoline or other 

flammable vapors and liquids in the vicinity 

of this or any other appliance.

 

 WHAT TO DO IF YOU SMELL GAS: 

• 

 Do not try to light any appliance. 

• 

 Do not touch any electrical switch; do not 

use any phone in your building. 

• 

 Immediately call your gas supplier from 

a neighbor’s phone. Follow the gas 

supplier’s instructions. 

• 

If you cannot reach your gas supplier, call 

the fire department.

 

Installation and service must be performed 

by a qualified installer, service agency or the 

gas supplier.

 

 Ne pas entreposer ni utilizer d’essence ni d’autres 

vapeurs  ou liquides inflammables dans le voisinage 

de cet appareil ou de tout autre appareil.

 

 QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ : 

• 

 Ne pas tenter d’allumer d’appareil.

• 

Ne touchez à aucan interrupteur. Ne pas vous 

servir des téléphones se trouvant dans le bâtiment 

où vous trouvez.

• 

Appelez immédiatement votre fournisseur de 

gaz depuis un voisin. Suivez les instructions du 

fournisseur.

• 

Si vous ne pouvez rejoindre le fournisseur de gaz, 

appelez le service des incindies.

 

L’installation et l’entretien doivent être assurés par un 

installateur ou un service d’entretien qualifié ou par le 

fournisseur de gaz.

PFS

®

US

C

Installation and Operation Instructions
Superior™ Stainless Outdoor Linear 

Fireplace 

Models

P/N 127035-01   Rev. C  04/2015

REPORT NO. F12-052

VRE4543EP

VRE4543EN 

P127035-01

Содержание VRE4543

Страница 1: ...uivre les instructions donn es dans cette notice pour r duire au minimum le risque d incindie ou d explosion ou pour viter tout dommage mat riel toute blessure ou la mort Do not store or use gasoline...

Страница 2: ...y be present even though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this fireplace WARNING Any cha...

Страница 3: ...box or on adjacent walls or furniture 8 Do not run fireplace where flammable liquids or vapors are used or stored under dusty conditions SAFETY Continued 9 Do not use this fireplace to cook food or b...

Страница 4: ...Flange Access Door Top Spacers PRODUCT FEATURES OPERATION This fireplace is clean burning It requires no outside venting There is no heat loss out a vent or up a chimney Heat is generated by realistic...

Страница 5: ...e mantels may discolor INSTALLATION Continued Figure 2 Framing Clearances for One Sided Application Figure 3 Framing Clearances for See Thru Application 17 50 53 25 38 15 25 53 25 38 17 50 53 25 38 Fi...

Страница 6: ...6 INSTALLATION Continued Figure 6 VRE4543E Series Dimensions 11 13 16 16 1 2 17 1 2 5 8 29 13 16 8 1 4 1 55 1 16 52 47 44 1 16 29 25 32 7 1 32 16 9 32 2 716 1 816 8 255 13 217 1 816 3 208 Gas Line Acc...

Страница 7: ...Aqualifiedservicepersonmustconnect fireplace to gas supply Follow all local codes CAUTION Never connect propane LP fireplace di rectly to the propane LP supply This fireplace requires an external reg...

Страница 8: ...s This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged fireplace valves Never use sealant on flare threads WARNING Use pipe joint sealant that is resist...

Страница 9: ...alve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Figure 11 2 Pressurize supply piping system by either...

Страница 10: ...rd mounting bracket and replace screws FINISHING FIREPLACE FOR INSTALLATION The VRE4543 series fireplace come with the rear panel semi installed If you will be using the fireplace for a one sided regu...

Страница 11: ...r Figure 20 Installing Access Door Retaining Brackets for See Thru Applications Figure 21 Installing Side Face Filler for See Thru Applications Removing Rear Interior Wall 1 Through firebox opening in...

Страница 12: ...the electronic access cover See Figure 23 3 Remove electronic access cover by gently pulling up and out of the fireplace There are two switches connected to cover 4 The control module is located on t...

Страница 13: ...shield that is covering the module and remove the screw on top Use a small thin object like a paper clip not sharp points to press and release the learn button There will be a beep sound from the mod...

Страница 14: ...1 STOP Read the safety information column 1 2 Make sure equipment shutoff valve is fully open 3 Turn safety shutoff switch to the OFF position 4 Remove access cover 5 Turn equipment shutoff valve cloc...

Страница 15: ...any large clumps of dust have now been pushed into the burner repeat steps 3 and 4 above BURNER PRIMARY AIR HOLES Air is drawn into the burner through the holes in the fitting at the burner entrance...

Страница 16: ...Orange Red Brown Black Solenoid White Brown Brown Green Ignitor Pilot I S AUX AF 5000MOD AF 4000 AF 4000B P Control Module Black Black SWI SWI GND Red HI LO Main Black BATTERY PACK Black Red Black Re...

Страница 17: ...losed 2 Air in gas lines when installed 3 Depleted gas supply propane LP only 4 Control module not in REMOTE position 5 Gas control valve pressure setting is not correct 6 Inlet gas pressure is too lo...

Страница 18: ...tor assembly is relighting the burner 4 Wire connection loose or wire broken REMEDY 1 Contact local natural or propane LP gas company 2 Clean burner see Cleaning and Main tenance page 18 or replace bu...

Страница 19: ...every one second Gas odor during combustion POSSIBLE CAUSE 1 Appliance burning vapors from paint hair spray glues cleaners chemicals new carpet etc See IMPORTANT statement above 2 Low fuel supply prop...

Страница 20: ...SuperiorFireplaces US com 127035 01C 20 PARTS MODELS VRE4543EN AND VRE4543EP 1 2 4 4 4 4 5 8 6 7 3 9 10 11 19 20 21 12 12 13 14 4 22 15 16 18 17...

Страница 21: ...399 Brass Elbow 2 11 111817 01 Flextube 1 12 125932 01 Burner Gasket 2 13 126050 02 Electronic Access Cover LVFO 1 14 126051 01 Insulation Heat Shield 1 15 125976 02 Bracket Valve Components 1 16 1460...

Страница 22: ...5768 03 Access Door Stainless 1 13 125766 02 Side Face Filler Stainless 2 14 125975 02 Fireplace Hood Stainless 1 15 126399 01 Glass tempered 1 16 126397 01 Bracket Glass Retainer 2 17 125753 02 Pebbl...

Страница 23: ...ified heat for propane LP unit propane LP gas supply may be low You may feel your gas pressure is too low If so contact your local gas supplier TECHNICAL SERVICE You may have further questions about i...

Страница 24: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 25: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 26: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 27: ...to burn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in...

Страница 28: ...ns pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2014 IHP LLC P N 127035 01 Rev C 04 2015 P127035 01 1508 Elm Hill P...

Отзывы: