POSSIBLE CAUSE

1. Not enough air

2. Gas regulator defective

1. Residues from manufac-

turing processes and logs 

curing

1. Turning control knob to HI 

position when burners are 

cold

2. Air in gas line

3. Air passageways on heater 

blocked

4. Dirty or partially clogged 

burner orifice(s)

1. When heated, vapors from 

furniture polish, wax, carpet 

cleaners, etc. may turn into 

white powder residue

1. Not enough combustion/

ventilation air

1. Battery is not installed. Bat-

tery power is low

1. Metal expanding while 

heating or contracting while 

cooling

2. Wire connection loose or 

wire broken

REMEDY 

1. Check burner(s) for dirt 

and debris. If found, clean 

burner(s) (see 

Cleaning and 

Maintenance

, page 30)

2. Replace gas regulator

1. Problem will stop after a few 

hours of operation

1. Turn control knob to LO 

position and let warm up 

for a minute

2. Operate burners until air is 

removed from line. Have 

gas line checked by local 

natural or propane/LP gas 

company

3. Observe minimum installa-

tion clearances (see pages 

9 through 11)

4. Clean burners (see 

Clean-

ing and Maintenance

page 30) or replace burner 

orifice(s)

1. Turn heater off when us-

ing  furniture  polish,  wax, 

carpet cleaners or similar 

products

1. Refer to 

Air for Combustion 

and Ventilation

 require-

ments (page 6)

1. Replace 9-volt batteries 

in receiver and hand-held 

remote

1. This is normal with most 

heaters. If noise is exces-

sive, contact qualified ser

-

vice person

2. Check wiring connections 

(see 

wiring diagram

,

 page 

31). Replace wire harness 

if necessary.

OBSERVED PROBLEM

Yellow flame in front burner 

during burner combustion

Slight smoke or odor during 

initial operation

Heater produces a whistling 

noise when burners are lit

White powder residue form-

ing within burner box or on 

adjacent walls or furniture

Moisture/condensation no-

ticed on windows

Remote does not function 

(Remote-Ready Models 

Only)

Heater produces a clicking/

ticking noise just after burners 

are lit or shut off

TROUBLESHOOTING

Continued

Содержание VFGT24NR

Страница 1: ...this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs This is an unvented gas fired heater It uses air oxyg...

Страница 2: ...s air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ven tilation section on page 6 of this manua...

Страница 3: ...tcon tainsand orgenerateschemicals known to the state of California to cause cancer or birth defects or other reproductive harm IMPORTANT Read this owner s manualcarefullyandcompletely before trying t...

Страница 4: ...r similar products turn heater off If heated thevaporsfromtheseproductsmay create a white powder residue within burner box or on adjacent walls and furniture 10 This heater needs fresh outside air ven...

Страница 5: ...thermostat or hand held thermostat may not be used where vented decorative list ing is required Variable remote control models include a ther mostat remote control UNPACKING CAUTION Donotremovethe da...

Страница 6: ...e your home energy efficient your home needs to breathe Fresh air must enter your home All fuel burning ap pliances need fresh air for proper combustion and ventilation Exhaust fans fireplaces clothes...

Страница 7: ...51 200 maximum Btu Hr the space can support 3 Add the Btu Hr of all fuel burning appliances in the space Vent free fireplace ___________ Btu Hr Gas water heater ___________ Btu Hr Gas furnace _______...

Страница 8: ...2 You can also remove door into adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or...

Страница 9: ...e air exist may discolor walls or cause odors IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing heater in rooms without enough ventilation air may cause mildew...

Страница 10: ...earances If Not Using Mantel Note If using a mantel proceed to If Using Mantel If not using a mantel follow these instructions You must have noncombustible material s above the fireplace opening Nonco...

Страница 11: ...Shelf Figure 9 Minimum Fireplace Clearances Above Combustible Flooring NOTICE Surface temperatures ofadjacentwallsandmantelsbe comehotduringoperation Walls and mantels above the firebox may become hot...

Страница 12: ...see Fig ure 10 The damper clamp will keep damper open Installation instructions are included with clamp accessory See chart below for minimum permanent flue opening you must provide Attach damper clam...

Страница 13: ...ons in mortar joint of bricks 4 Remove heater base from fireplace 5 Drill holes at marked locations using 3 16 drill bit 6 Attachbase throughholesinbacksidepan els of base to fireplace floor using mas...

Страница 14: ...1 2 diameter or greater to allow proper gas volume to heater Ifpipeistoosmall undue loss of volume will occur Installation must include an equipment shutoff valve union and plugged 1 8 NPT tap Locate...

Страница 15: ...valve control valve and equip ment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig 3 5 KpA will damage heater regulator 2 Cap off open end of gas pipe where equip ment shut...

Страница 16: ...ote control accessories are available separately see Accessories page 40 Read instructions shipped with remote control along with instructions below before attempting installation 1 If unit is already...

Страница 17: ...selector switch is in OFF posi tion before installing or chang ing batteries in your hand held remote or receiver Hand Held Remote Control The hand held remote control uses 3 AAA batteries not includ...

Страница 18: ...gures 23 23A 23B and 23C for reference The log has a rectangular shape on the bottom that fits against the lip on the black metal base the square grate and the round tube burner Slide the log in place...

Страница 19: ...og Back Left Log D 060 D 018 or D026 Flat Part of Log Log Notch Burner Tube Figure 24A Installing Back Left Log Figure 24B Installing Back Left Log D 018 Rear View Burner Tube Log Notch Vertical Porti...

Страница 20: ...Log Figure 26A Installing Charred Log Top View Figure 26B Installing Charred Log Top Side View Square Grate Log Notch of the log faces forward The log has a notch that fits around the burner tube on...

Страница 21: ...The left end of this log has a square hole that fits over a square peg that is on the top of the middle split log The right end of this log rests behind the knot on the top of the front right log 8 Fi...

Страница 22: ...ut shall not be allowed to come in contact with either the burner ports or flame around base of heater if de sired DO NOT place rock or additional logs on front burner or on logs except as directed ab...

Страница 23: ...part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS WARNING If fireplace has glass doors never operate this heater with glass doors closed If you op eratehe...

Страница 24: ...be running this heater for the first time after hooking up to gas supply If so the control knob may need to be pressed in for 30 seconds or more This will allow air to bleed from the gas system 7 Wit...

Страница 25: ...st turned off You can now turn burner on and off with hand held remote control unit IMPORTANT Do not leave selector switch in the REMOTE or ON position when pilot is not lit This will drain the batter...

Страница 26: ...nd Ignitor Button Location O F F PILOT O N Control Knob Ignitor Button 7 With control knob pressed in press and release ignitor button This will light pilot The pilot is attached to the front burner I...

Страница 27: ...r helps distribute heated air from the fireplace Note Periodically check the louvers of the firebox and remove any dust dirt or other obstructions Figure 38 Pilot Natural Propane LP HAND HELD REMOTE O...

Страница 28: ...lames through 5 levels see Figure 43 Select manual flame height function by press ing MODE button until a flame is shown in lower left corner of display Use UP DOWN arrow button to set desired flame h...

Страница 29: ...into hole on receiver face plate marked PRG The receiver will beep 3 times to indicate it is ready to accept a new remote transmitter Press the ON OFF button on your remote and the receiver will beep...

Страница 30: ...ector holder for dust and dirt see Figure 49 3 Blow air through the ports slots and holes in the burner 4 Check injector holder located at end of burner tube again Remove any large particles of dust d...

Страница 31: ...R VFGT30NV VFGT36NR AND VFGT36NV Rating Variable 29 000 40 000 Btu Hr Type Gas Natural Ignition Electronic Manifold Pressure 3 4 W C Inlet Gas Pressure in of water Max 10 5 W C Min 5 W C For purpose o...

Страница 32: ...r in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Overlap ember material 1 4 see page 18 1 Reconnect ignitor...

Страница 33: ...trol knob pressed in 30 seconds 3 Wait one minute for safety interlock system to reset Repeat ignition operation 4 Fully open equipment shut off valve 5 A Contact local natural or propane LP gas compa...

Страница 34: ...ir is removed from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum installa tion clearances see pages 9 through 11 4 Clean burners see Clean ing and Maintenance...

Страница 35: ...clogged 1 Gas leak See Warning statement at top of page 2 Control valve or gas control defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of page 1 Han...

Страница 36: ...RTS REMOTE READY VARIABLE CONTROL MODELS VFGT24NR VFGT24NV VFGT24PR VFGT24PV VFGT30NR VFGT30NV VFGT30PR VFGT30PV VFGT36NR VFGT36NV VFGT36PR AND VFGT36PV 2 1 3 4 5 6 7 8 9 31 32 33 11 30 12 13 14 15 16...

Страница 37: ...023 01 Bracket Front Burner 2 13 097384 01 Nut Captive Washer 2 14 112829 02 Air Shutter 1 15 124933 01 Orifice Holder 90 Degree 1 16 099056 46 Orifice 051 Pan 1 099046 45 Orifice 028 Pan 1 17 M11084...

Страница 38: ...T NO Log Id PART NO Log Id PART NO Log Id DESCRIPTION QTY 1 125948 01 D 061 125573 01 D 019 125591 01 D 027 Log Front Right 1 2 125948 02 D 060 125573 02 D 018 125591 02 D 026 Log Back Left 1 3 125948...

Страница 39: ...g have ready your name your address model and serial numbers of your heater how heater was malfunctioning purchase date Usually we will ask you to return the part to the factory SERVICE HINTS When Gas...

Страница 40: ...of your easy chair RECEIVER AND REMOTE CONTROL KIT TSRC For all Remote Ready Models Allows the burner system to be operated in a manually or thermostatically controlled mode Remote is programmable fo...

Страница 41: ...ll produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product...

Страница 42: ...IS WARRANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ________________...

Страница 43: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 44: ...126802 01 Rev A 01 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126802 01...

Отзывы: