TO TURN OFF GAS

 

TO APPLIANCE

1.  Turn control knob clockwise 

 to the 

OFF position.

2a. Set switch in the OFF position.

2b. 

If Using Optional Hand-Held Remote: 

Set selector switch in the OFF position to 

prevent draining battery. 

3.  Close equipment shutoff valve (see Figure 

15, page 15).

MANUAL LIGHTING 

PROCEDURE

1.  Follow steps 1 through 6 under 

Lighting 

Instructions

, page 23.

2.  Press control knob and light pilot with 

match. 

3.  Keep control knob pressed in for 30 

seconds after lighting pilot. After 30 sec-

onds, release control knob. Now follow 

steps 9 through 11, 

Lighting Instructions

page 23.

OPTIONAL HAND-HELD

 

REMOTE OPERATION

Note: All remote control accessories must 

be purchased separately (see Accessories, 

page 40). Follow instructions included with 

the remote control.

NOTICE: You must light the pilot 

before using the hand-held re-

mote control unit. See 

Lighting 

Instructions

 on page 23.

After  lighting,  let  pilot  flame  burn  for  about 

one minute. Turn control knob to ON posi-

tion. Adjust flame adjustment knob anywhere 

between HI and LO. Slide the selector switch 

to the REMOTE position (see Figure 36). 

Figure 35 - Control Knob, Ignitor Button 

and Remote Selector Switch

Selector 

Switch 

Control 

Knob in OFF 

Position 

Flame 

Adjustment 

Knob 

Ignitor

Note: The burner may light if hand-held re-

mote was on when selector switch was last 

turned off. You can now turn burner on and off 

with hand-held remote control unit.

 

IMPORTANT: 

Do not leave selector switch in 

the REMOTE or ON position when pilot is not 

lit. This will drain the battery.

Note: Do not hold hand-held remote for a long 

time. Body temperature will affect its operation 

in the AUTO mode.

FOR YOUR SAFETY

 

READ BEFORE LIGHTING

 WARNING: If you do not fol-

low these instructions exactly, 

a  fire  or  explosion  may  result 

causing property damage, per-

sonal injury or loss of life.

A.  This appliance has a pilot which must 

be lighted by hand. When lighting 

the pilot, follow these instructions 

exactly.

B.  BEFORE  LIGHTING  smell  all  around 

the appliance area for gas. Be sure to 

smell next to the floor because some 

gas is heavier than air and will settle 

on the floor.

 

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do 

not use any phone in your building.

• Immediately  call  your  gas  supplier 

from a neighbor’s phone. Follow the 

gas supplier’s instructions.

• If you cannot reach your gas supplier, 

call the fire department.

C.  Use only your hand to push in or turn 

the gas control knob. Never use tools. 

If the knob will not push in or turn by 

hand, don’t try to repair it, call a quali

-

fied service technician or gas supplier. 

Force or attempted repair may result in 

a fire or explosion.

D.  Do not use this appliance if any part 

has been under water. Immediately call 

a qualified service technician to inspect 

the appliance and to replace any part of 

the control system and any gas control 

which has been under water.

VARIABLE REMOTE 

MODELS OPERATION

Содержание VFGT24NR

Страница 1: ...this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs This is an unvented gas fired heater It uses air oxyg...

Страница 2: ...s air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ven tilation section on page 6 of this manua...

Страница 3: ...tcon tainsand orgenerateschemicals known to the state of California to cause cancer or birth defects or other reproductive harm IMPORTANT Read this owner s manualcarefullyandcompletely before trying t...

Страница 4: ...r similar products turn heater off If heated thevaporsfromtheseproductsmay create a white powder residue within burner box or on adjacent walls and furniture 10 This heater needs fresh outside air ven...

Страница 5: ...thermostat or hand held thermostat may not be used where vented decorative list ing is required Variable remote control models include a ther mostat remote control UNPACKING CAUTION Donotremovethe da...

Страница 6: ...e your home energy efficient your home needs to breathe Fresh air must enter your home All fuel burning ap pliances need fresh air for proper combustion and ventilation Exhaust fans fireplaces clothes...

Страница 7: ...51 200 maximum Btu Hr the space can support 3 Add the Btu Hr of all fuel burning appliances in the space Vent free fireplace ___________ Btu Hr Gas water heater ___________ Btu Hr Gas furnace _______...

Страница 8: ...2 You can also remove door into adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or...

Страница 9: ...e air exist may discolor walls or cause odors IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing heater in rooms without enough ventilation air may cause mildew...

Страница 10: ...earances If Not Using Mantel Note If using a mantel proceed to If Using Mantel If not using a mantel follow these instructions You must have noncombustible material s above the fireplace opening Nonco...

Страница 11: ...Shelf Figure 9 Minimum Fireplace Clearances Above Combustible Flooring NOTICE Surface temperatures ofadjacentwallsandmantelsbe comehotduringoperation Walls and mantels above the firebox may become hot...

Страница 12: ...see Fig ure 10 The damper clamp will keep damper open Installation instructions are included with clamp accessory See chart below for minimum permanent flue opening you must provide Attach damper clam...

Страница 13: ...ons in mortar joint of bricks 4 Remove heater base from fireplace 5 Drill holes at marked locations using 3 16 drill bit 6 Attachbase throughholesinbacksidepan els of base to fireplace floor using mas...

Страница 14: ...1 2 diameter or greater to allow proper gas volume to heater Ifpipeistoosmall undue loss of volume will occur Installation must include an equipment shutoff valve union and plugged 1 8 NPT tap Locate...

Страница 15: ...valve control valve and equip ment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig 3 5 KpA will damage heater regulator 2 Cap off open end of gas pipe where equip ment shut...

Страница 16: ...ote control accessories are available separately see Accessories page 40 Read instructions shipped with remote control along with instructions below before attempting installation 1 If unit is already...

Страница 17: ...selector switch is in OFF posi tion before installing or chang ing batteries in your hand held remote or receiver Hand Held Remote Control The hand held remote control uses 3 AAA batteries not includ...

Страница 18: ...gures 23 23A 23B and 23C for reference The log has a rectangular shape on the bottom that fits against the lip on the black metal base the square grate and the round tube burner Slide the log in place...

Страница 19: ...og Back Left Log D 060 D 018 or D026 Flat Part of Log Log Notch Burner Tube Figure 24A Installing Back Left Log Figure 24B Installing Back Left Log D 018 Rear View Burner Tube Log Notch Vertical Porti...

Страница 20: ...Log Figure 26A Installing Charred Log Top View Figure 26B Installing Charred Log Top Side View Square Grate Log Notch of the log faces forward The log has a notch that fits around the burner tube on...

Страница 21: ...The left end of this log has a square hole that fits over a square peg that is on the top of the middle split log The right end of this log rests behind the knot on the top of the front right log 8 Fi...

Страница 22: ...ut shall not be allowed to come in contact with either the burner ports or flame around base of heater if de sired DO NOT place rock or additional logs on front burner or on logs except as directed ab...

Страница 23: ...part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS WARNING If fireplace has glass doors never operate this heater with glass doors closed If you op eratehe...

Страница 24: ...be running this heater for the first time after hooking up to gas supply If so the control knob may need to be pressed in for 30 seconds or more This will allow air to bleed from the gas system 7 Wit...

Страница 25: ...st turned off You can now turn burner on and off with hand held remote control unit IMPORTANT Do not leave selector switch in the REMOTE or ON position when pilot is not lit This will drain the batter...

Страница 26: ...nd Ignitor Button Location O F F PILOT O N Control Knob Ignitor Button 7 With control knob pressed in press and release ignitor button This will light pilot The pilot is attached to the front burner I...

Страница 27: ...r helps distribute heated air from the fireplace Note Periodically check the louvers of the firebox and remove any dust dirt or other obstructions Figure 38 Pilot Natural Propane LP HAND HELD REMOTE O...

Страница 28: ...lames through 5 levels see Figure 43 Select manual flame height function by press ing MODE button until a flame is shown in lower left corner of display Use UP DOWN arrow button to set desired flame h...

Страница 29: ...into hole on receiver face plate marked PRG The receiver will beep 3 times to indicate it is ready to accept a new remote transmitter Press the ON OFF button on your remote and the receiver will beep...

Страница 30: ...ector holder for dust and dirt see Figure 49 3 Blow air through the ports slots and holes in the burner 4 Check injector holder located at end of burner tube again Remove any large particles of dust d...

Страница 31: ...R VFGT30NV VFGT36NR AND VFGT36NV Rating Variable 29 000 40 000 Btu Hr Type Gas Natural Ignition Electronic Manifold Pressure 3 4 W C Inlet Gas Pressure in of water Max 10 5 W C Min 5 W C For purpose o...

Страница 32: ...r in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Overlap ember material 1 4 see page 18 1 Reconnect ignitor...

Страница 33: ...trol knob pressed in 30 seconds 3 Wait one minute for safety interlock system to reset Repeat ignition operation 4 Fully open equipment shut off valve 5 A Contact local natural or propane LP gas compa...

Страница 34: ...ir is removed from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum installa tion clearances see pages 9 through 11 4 Clean burners see Clean ing and Maintenance...

Страница 35: ...clogged 1 Gas leak See Warning statement at top of page 2 Control valve or gas control defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of page 1 Han...

Страница 36: ...RTS REMOTE READY VARIABLE CONTROL MODELS VFGT24NR VFGT24NV VFGT24PR VFGT24PV VFGT30NR VFGT30NV VFGT30PR VFGT30PV VFGT36NR VFGT36NV VFGT36PR AND VFGT36PV 2 1 3 4 5 6 7 8 9 31 32 33 11 30 12 13 14 15 16...

Страница 37: ...023 01 Bracket Front Burner 2 13 097384 01 Nut Captive Washer 2 14 112829 02 Air Shutter 1 15 124933 01 Orifice Holder 90 Degree 1 16 099056 46 Orifice 051 Pan 1 099046 45 Orifice 028 Pan 1 17 M11084...

Страница 38: ...T NO Log Id PART NO Log Id PART NO Log Id DESCRIPTION QTY 1 125948 01 D 061 125573 01 D 019 125591 01 D 027 Log Front Right 1 2 125948 02 D 060 125573 02 D 018 125591 02 D 026 Log Back Left 1 3 125948...

Страница 39: ...g have ready your name your address model and serial numbers of your heater how heater was malfunctioning purchase date Usually we will ask you to return the part to the factory SERVICE HINTS When Gas...

Страница 40: ...of your easy chair RECEIVER AND REMOTE CONTROL KIT TSRC For all Remote Ready Models Allows the burner system to be operated in a manually or thermostatically controlled mode Remote is programmable fo...

Страница 41: ...ll produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product...

Страница 42: ...IS WARRANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ________________...

Страница 43: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 44: ...126802 01 Rev A 01 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126802 01...

Отзывы: