FRAMING SPECIFICATIONS

Figure 6

Figure 7

Figure 8

Opening

UVF-500

UVF-600

A

41 

¹⁄₄

"

46 

¹⁄₄

"

B

37 

¹⁄₂

"

43 

¹⁄₂

"

C

27 

¹⁄₂

"

31 

³⁄₄

"

D

13 

³⁄₄

"

15 

⁷⁄₈

"

E

66 

³⁄₄

"

 73"

F

33 

³⁄₈

"

36 

¹⁄₂

"

G

19 

⁵⁄₈

"

20 

⁵⁄₈

"

H

47 

¹⁄₄

"

51 

⁵⁄₈

"

Framing Dimensions

Header

B

A

Corner Installation

H

D

C

A
E

G

F

Back Wall Of Chase/Enclosure

Including Finishing Materials

If Any

Rough

Framing Face

(Unfinished Shown)

A

G

C

Back Wall Of Chase/Enclosure

Including Finishing Materials

If Any

Rough Framing Face

(Unfinished Shown)

Содержание UVFC-500

Страница 1: ...CAUSINGPROPERTYDAMAGE PERSONAL INJURY OR LOSS OF LIFE WARNING IMPROPER INSTALLATION ADJUSTMENT AL TERATION SERVICE OR MAINTENANCE CAN CAUSE IN JURY OR PROPERTY DAMAGE REFER TO THIS MANUAL FOR ASSISTAN...

Страница 2: ...ANSI Z21 11 2 approved Decora tive Type Unvented Gas Log Room Heaters For the appropriate Unvented Gas Log Room Heatermodel refertothechartbelow Referto the installation instructions provided with the...

Страница 3: ...room or bathroom Theapplianceanditsindividualshut offvalve must be disconnected from the gas supply pipingsystemwhileperforminganytestsofthe gas supply piping system at pressures in ex cess of psig T...

Страница 4: ...oexistingconstruc tion See Figure 1 for location suggestions WARNING MAINTAIN MINIMUM CLEARANCES Do not install in the vicinity where gasoline or other flammable liquids may be stored The unvented fir...

Страница 5: ...sign and framing reference only Actual installations may vary due to individual design preferences How ever always maintain minimum clearances to combustible materials and do not violate any specific...

Страница 6: ...cial floor support is needed for the firebox however to be certain 1 Estimate the total weight of the firebox systemandsurroundmaterialssuchasmarble brick stone etc to be installed 2 Measure the squar...

Страница 7: ...m the drywall surface It is important that this dimension be exact IMPORTANT UNDER NO CIRCUMSTANCES SHALL THE FIREBOX TOP SPACERS BE RE MOVED OR MODIFIED THE HEADER MAY BE IN DIRECT CONTACT WITH THE T...

Страница 8: ...7 43 C 27 31 D 13 15 E 66 73 F 33 36 G 19 20 H 47 51 Framing Dimensions Header B A Corner Installation H D C A E G F Back Wall Of Chase Enclosure Including Finishing Materials If Any Rough Framing Fac...

Страница 9: ...tion of the mantel clearances the canopy must be installed Canopy Installation The factory supplied canopy must be installed onthefireboxforsafeoperation SeeFigure10 8d Nail Figure 9 Grounded to Appli...

Страница 10: ...ntels to rustic wood paneling or warm brick facings Only noncombustible materials like marble stone tile brick etc may overlap the black front facing but be sure not to block the upper orlowergrilles...

Страница 11: ...DESCRIPTION Part No Qty Part No Qty Gas Fireplace Assembly 1 Firescreen 36L89 2 36L99 2 2 Rod Screen 88L95 2 88L96 2 3 Refractory Side 88L59 2 88L65 2 4 Refractory Rear 88L58 1 88L64 1 5 Refractory Ba...

Страница 12: ...eserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace c...

Отзывы: