NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.

2

WARNING: THESE BUILT-IN UN-
VENTED FIREBOXES HAVE ONLY
BEEN TESTED AND APPROVED FOR
USE WITH ANSI Z21.11.2 UN-
VENTED GAS LOGS.

DO NOT ATTEMPT TO BURN SOLID
WOOD FUELS, OTHER GAS LOG SETS
OR ANY OTHER COMBUSTIBLE MATE-
RIALS IN THIS UNVENTED FIREBOX.

Log Set Sizing Reference Chart

Unvented Firebox

Unvented Room Heater Log Set

 Model

Natural

Propane (L.P.G)

Check the inventory list to be sure that you have
all the necessary parts in usable condition. Also
check for concealed damage.

Inventory

Unvented Gas Firebox
Canopy
Gas Connector Fittings
Installation and Operating Instructions

Tools and Building Supplies
Normally Required

Tools Should Include:

Phillips screwdriver
Hammer
Saw and/or sabersaw
Level
Measuring tape
Electric drill and bits
Pliers
Square
Piping complying with local codes
Pipe wrench
Tee joint
Pipe compound

Building Supplies Should Include:

Framing materials
Wall finishing materials
Caulking materials (noncombustible)
Fireplace surround materials
(noncombustible)

IMPORTANT SAFETY INFORMATION

INSTALLER: PLEASE LEAVE THESE INSTRUC-
TIONS WITH THE OWNER.

OWNER: PLEASE RETAIN THESE INSTRUC-
TION FOR FUTURE REFERENCE

IMPORTANT: BEFORE STARTING YOUR FIRE-
BOX INSTALLATION, READ THESE INSTALLA-
TION INSTRUCTIONS CAREFULLY TO BE SURE
YOU UNDERSTAND THEM COMPLETELY AND
IN ENTIRETY. FAILURE TO FOLLOW THESE
INSTRUCTIONS COULD CAUSE A HEATER
MALFUNCTION RESULTING IN SERIOUS IN-
JURY AND/OR PROPERTY DAMAGE.

WARNING: ANY CHANGE TO THIS UN-
VENTED ROOM HEATER CAN BE DAN-
GEROUS. IMPROPER INSTALLATION OR
USE OF THIS HEATER CAN CAUSE SERI-
OUS INJURY OR DEATH FROM FIRE,
BURNS, EXPLOSION OR CARBON MON-
OXIDE POISONING.

GENERAL INFORMATION

These ventless firebox enclosures are designed
to accept all ANSI Z21.11.2 approved Decora-
tive Type Unvented Gas Log Room Heaters.
For the appropriate Unvented Gas Log Room
Heater model, refer to the chart below. Refer to
the installation instructions provided with the
log sets for detailed instructions.

The UVFC Series are unvented fireboxes. They
feature a self-contained heat-circulating system.

The UVFR Series is a conventional radiant-
heat unvented firebox.

This installation manual will enable you to
obtain a safe, efficient and dependable instal-
lation of your room heater system.

Do not alter or modify the firebox or its com-
ponents under any circumstances. Any modifi-
cation or alteration of the firebox system, in-
cluding but not limited to the firebox and acces-
sories, may void the warranty, listings and
approvals of this system and could result in an
unsafe and potentially dangerous installation.

These Built-In Unvented Fireboxes have been
tested and approved as Ventless Firebox Enclo-
sures for Gas-Fired Decorative Type Ventless
Room Heaters to IAS 2-97.

TABLE OF CONTENTS

Firebox/Log Set Reference Chart ..... page

2

General Information ......................... page

2

Inventory ......................................... page

2

Tools/Building Supplies ................... page

2

Important Safety Information .......... page

2

Codes .............................................. page

3

Combustion and Ventilation Air ....... page

3

Location of firebox ........................... page

4

Clearances ....................................... page

4

Assembly Steps ............................... page

5

Gas Line Installation ........................ page

5

Firebox Framing ............................... page

6

UVF-500 Specifications ................... page

6

Firebox Installation .......................... page

7

UVF-600 Specifications ................... page

7

Framing Specifications .................... page

8

Canopy Installation .......................... page

9

Optional Equipment ......................... page

9

Firebox finishes ............................... page 10

Replacement Parts .......................... page 10

Accessories/Components ................ page 10

Replacement Parts List .................... page 11

UVFC-500

VFGL-18/24MN/VN-3

VFGL-18/24MP/VP-3

PVFGL-18MN/VN

PVFGL-18MP/VP

UVFC-600

VFGL-24/28MN/VN-3

VFGL-24/28MP/VP-3

PVFGL-24MN/VN

PVFGL-24MP/VP

UVFR-500

VFGL-18/24MN/VN-3

VFGL-18/24MP/VP-3

PVFGL-18MN/VN

PVFGL-18MP/VP

UVFR-600

VFGL-24/28MN/VN-3

VFGL-24/28MP/VP-3

PVFGL-24MN/VN

PVFGL-24MP/VP

Содержание UVFC-500

Страница 1: ...CAUSINGPROPERTYDAMAGE PERSONAL INJURY OR LOSS OF LIFE WARNING IMPROPER INSTALLATION ADJUSTMENT AL TERATION SERVICE OR MAINTENANCE CAN CAUSE IN JURY OR PROPERTY DAMAGE REFER TO THIS MANUAL FOR ASSISTAN...

Страница 2: ...ANSI Z21 11 2 approved Decora tive Type Unvented Gas Log Room Heaters For the appropriate Unvented Gas Log Room Heatermodel refertothechartbelow Referto the installation instructions provided with the...

Страница 3: ...room or bathroom Theapplianceanditsindividualshut offvalve must be disconnected from the gas supply pipingsystemwhileperforminganytestsofthe gas supply piping system at pressures in ex cess of psig T...

Страница 4: ...oexistingconstruc tion See Figure 1 for location suggestions WARNING MAINTAIN MINIMUM CLEARANCES Do not install in the vicinity where gasoline or other flammable liquids may be stored The unvented fir...

Страница 5: ...sign and framing reference only Actual installations may vary due to individual design preferences How ever always maintain minimum clearances to combustible materials and do not violate any specific...

Страница 6: ...cial floor support is needed for the firebox however to be certain 1 Estimate the total weight of the firebox systemandsurroundmaterialssuchasmarble brick stone etc to be installed 2 Measure the squar...

Страница 7: ...m the drywall surface It is important that this dimension be exact IMPORTANT UNDER NO CIRCUMSTANCES SHALL THE FIREBOX TOP SPACERS BE RE MOVED OR MODIFIED THE HEADER MAY BE IN DIRECT CONTACT WITH THE T...

Страница 8: ...7 43 C 27 31 D 13 15 E 66 73 F 33 36 G 19 20 H 47 51 Framing Dimensions Header B A Corner Installation H D C A E G F Back Wall Of Chase Enclosure Including Finishing Materials If Any Rough Framing Fac...

Страница 9: ...tion of the mantel clearances the canopy must be installed Canopy Installation The factory supplied canopy must be installed onthefireboxforsafeoperation SeeFigure10 8d Nail Figure 9 Grounded to Appli...

Страница 10: ...ntels to rustic wood paneling or warm brick facings Only noncombustible materials like marble stone tile brick etc may overlap the black front facing but be sure not to block the upper orlowergrilles...

Страница 11: ...DESCRIPTION Part No Qty Part No Qty Gas Fireplace Assembly 1 Firescreen 36L89 2 36L99 2 2 Rod Screen 88L95 2 88L96 2 3 Refractory Side 88L59 2 88L65 2 4 Refractory Rear 88L58 1 88L64 1 5 Refractory Ba...

Страница 12: ...eserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace c...

Отзывы: