Superior UVF-36 and Скачать руководство пользователя страница 2

NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.

2

IMPORTANT SAFETY 
INFORMATION

INSTALLER: PLEASE LEAVE THESE INSTRUC-
TIONS WITH THE OWNER.

OWNER: PLEASE RETAIN THESE INSTRUC-
TIONS FOR FUTURE REFERENCE.

     

WARNING

If the information in this 
manual is not follwed 
exactly, a fi re or explosion 
may result causing prop-
erty damage, personal 
injury or loss of life.

       

IMPORTANT

Before starting your fi rebox instal-
lation, read these installation 
instructions carefully to be sure you 
understand them completely and 
in entirety. Failure to follow these 
instructions could cause a heater 
malfunction resulting in serious 
injury and/or property damage.

       

IMPORTANT

The fi replace screens on the appli-
ance must be closed prior to operat-
ing the fi replace.

       

WARNING

These built-in vent-free fi reboxes 
have only been tested and approved 
for use with ANSI Z21.11.2 Vent-
free gas logs.

       

WARNING

Any change to this Vent-Free room 
heater can be dangerous. Improper 
installation or use of this heater can 
cause serious injury or death from 
fi re, burns, explosion or carbon 
monoxide poisoning.

       

WARNING

Do not attempt to burn solid wood 
fuels, other gas log sets or any 
other combustible materials in 
this vent-free fi rebox.

       

WARNING

Carbon Monoxide Poisoning: Early 
signs of carbon monoxide poisoning 
are similar to the fl u  with  head-
aches, dizziness and/or nausea. If 
you have these signs, obtain fresh 
air immediately. Have the Vent-Free 
Gas Heater serviced as it may not 
be operating correctly.

       

WARNINGS

• Due to high temperatures, the 

fi rebox should be located out of 
traffi c and away from furniture 
and draperies.

•   Do not place clothing or other 

fl ammable material on or near 
the heater.

•  Any safety screen or guard re-

moved for servicing the fi rebox 
must be replaced and/or closed 
prior to operating the heater.

• Installation and repair should 

be done by a qualifi ed service 
person. The heater should be 
inspected before use and at 
least annually by a professional 
service person. More frequent 
cleaning may be required due 
to excessive lint from carpet-
ing, bedding material, etc. It is 
important that control compart-
ments, burners and circulating 
air passageways of the heater 
be kept clean.

•  Allow the heater to cool before 

servicing. Always shut off any 
electricity or gas to the heater 
while performing service work.

• Do not install the fi rebox in a 

sleeping room or bathroom.

•  The appliance and its individual 

shut-off valve must be discon-
nected from the gas supply piping 
system while performing any 
tests of the gas supply piping 
system at test pressures equal 
to or less than 1/2 psig.

       

WARNING

•  The heater must be isolated from 

the gas supply piping system by 
closing its individual manual 
shut-off valve during any pres-
sure testing of the gas supply 
piping system at test pressures 
equal to or less than 1/2 psig.

•  Keep heater area clear and free 

from combustible materials, 
gasoline and other fl ammable 
vapors and liquids.

• Do not use this heater if any 

part has been under water. Im-
mediately call a qualifi ed service 
technician to inspect the heater 
and to replace any part of the con-
trol system and any gas control 
which has been under water.

•  Ensure that the heater is clean 

when operating. Excessive dust 
accumulation on the burner and 
logs will increase the amount of 
carbon monoxide formation and 
could lead to carbon monoxide 
poisoning and death.

       

WARNING

Do not install in the vicinity where 
gasoline or other fl ammable liquids 
may be stored. The Vent-Free fi re-
box must be kept clear and free from 
these combustible materials.

       

WARNING

Maintain minimum clearances.

       

WARNING

Do not allow fans to blow directly 
into the fi replace. Avoid any drafts 
that alter burner fl ame patterns.

Содержание UVF-36 and

Страница 1: ...N AND OPERATING INSTRUCTIONS UVF 36 UVFRC 3628 UVFRC 3628 H UVFRC 4228 UVFRC 4228 H WARNING DO NOT ATTEMPT TO BURN SOLID WOOD FUELS OTHER GAS LOG SETS OR ANY OTHER COMBUSTIBLE MATERIALS IN THIS VENT F...

Страница 2: ...ed and or closed prior to operating the heater Installation and repair should be done by a qualified service person The heater should be inspected before use and at least annually by a professional se...

Страница 3: ...on Page 12 Firebox Finishes Page 15 Accessories components Page 15 Replacement Parts List Page 17 This installation manual will help you obtain a safe efficient dependable installation for your applia...

Страница 4: ..._________ BTU Hr max the space can support _________ BTU Hr actual amount of BTU Hr used Example 61 440 BTU Hr max the space can support 66 000 BTU Hr actual amount of BTU Hr used The space in the abo...

Страница 5: ...ained In no case shall the clearances be such as to interfere with combustion air and accessibility d Installations shall be of a permanent type with a permanently piped fuel supply in accordance with...

Страница 6: ...ove Appliance all models Figure 3 CAUTION Do not install in the vicinity where gasolineorotherflammableliquids may be stored The Vent Free fire boxmustbekeptclearandfreefrom these combustible material...

Страница 7: ...s UVFRC 3628 and UVFRC 4228 WITH Canopy Installed Canopy is optional on these models 16 9 1 2 2 3 4 5 6 10 11 12 13 14 15 Top of Firebox Opening Screen Top of Appliance Combustible Mantel and Trim Hea...

Страница 8: ...ver and might require a different sequence Step 1 Position firebox prior to framing or into prepared framing Step 2 Field wire the main power supply to the appliance if a blower kit is to be installed...

Страница 9: ...If a wall covering such as drywall is to be attached to the rear wall then the depth must be measured from the drywall surface It is important that this dimension be exact Step 2 Level the firebox by...

Страница 10: ...0 lbs 26 Cu Ft H1956 UVFRC 4228 H 230 lbs 26 Cu Ft A canopy comes standard and is required for model UVF 36 The fac tory supplied canopy must be installed on the firebox for safe operation for model U...

Страница 11: ...re 13 Install three screws as shown in Figure 13 Make sure canopy is level and secure Step 3 Reinstall screen and rod assemblies see Figure 12 Framing Dimensions Opening UVF 36 UVFRC 3628 UVFRC 3628 H...

Страница 12: ...Green Wall mounted ON OFF Blower Switch or Variable Speed Control Switch Ground HOT SIDE OF RECEPTACLE An ON OFF Wall Switch is used with the FBK 100 kit field provided or sold separately order P N 8...

Страница 13: ...4 Locate the tabs shown in Figure 23 Position the blower assembly so that the tabs located on the cabinet base are seated in the notches of the blower bracket Bend the tabs over to secure the blower...

Страница 14: ...ake up slack Firebox floor Model UVFRC 4228 Shown Model UVFRC 4228 Locating Tabs Bend Locating Tabs Over into notches Use screw provided and secure in place as shown The notched side of cover plates g...

Страница 15: ...rm SIDE VIEW Firebox Floor Combustible Wall Figure 26 Raised Hearth Extension Non Combustible Wall see Figure 4 Fireplace Opening From Base to Bottom of Firebox Opening floor 5 3 4 Max Base APPROVED A...

Страница 16: ...Switch Kit shown below ON OFF Wall Switch Kit The ON OFF wall switch kit may be used to control the blower operation if FBK 100 blower kit is installed Install the ON OFF wall switch in a convenient l...

Страница 17: ...of the firebox with numbered parts and a replacement parts list can be found on the Page Normally all parts should be ordered through your distributor or dealer Parts will be shipped at prevailing pri...

Страница 18: ...NOTE DIAGRAMS ILLUSTRATION ARE NOT TO SCALE 18 NOTES...

Страница 19: ...NOTE DIAGRAMS ILLUSTRATION ARE NOT TO SCALE 19 NOTES...

Страница 20: ...est Taft Avenue Orange CA 92865 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and produ...

Отзывы: