INSTALLATION

Continued 

 WARNING: Never connect 

natural gas fireplace to private 

(non-utility)  gas  wells.  This 

gas  is  commonly  known  as 

wellhead gas.

Installation Items Needed

Before  installing  fireplace,  make  sure  you 

have the items listed below.
•  external regulator for propane/LP unit only 

(supplied by installer)

•  piping (check local codes)
•  sealant (resistant to propane/LP gas)
•  equipment shutoff valve *
•  test gauge connection *
•  sediment trap (optional)
•  tee joint
•  pipe wrench
•  approved  flexible  gas  line  with  gas  con

-

nector  (if  allowed  by  local  codes)  (not 

provided) 

* A  equipment  shutoff  valve  with  1/8"  NPT 

tap is an acceptable alternative to test gauge 

connection. Purchase the optional equipment 

shutoff valve from your dealer.

For  propane/LP  units,  the  installer  must 

supply an external regulator. The external 

regulator will reduce incoming gas pressure. 

You must reduce incoming gas pressure to 

between 11" and 14" of water. If you do not re

-

duce incoming gas pressure, heater regulator 

damage could occur. Install external regulator 

with the vent pointing down as shown in Figure 

17, page 14. Pointing the vent down protects 

it from freezing rain or sleet.

 CAUTION: Use only new, 

black  iron  or  steel  pipe.  Inter

-

nally-tinned copper tubing may 

be used in certain areas. Check 

your  local  codes.  Use  pipe  of 

1/2" diameter or greater to allow 

proper gas volume to fireplace. 

If pipe is too small, undue loss 

of volume will occur.

Mantel Clearances for Built-In 

Installation

If placing mantel above built-in fireplace, you 

must meet minimum clearance between man

-

tel shelf and top of fireplace opening.

NOTICE: If your installation does 

not meet the minimum clear-

ances shown, you must do one 

of the following: 

•  raise the mantel to an accept

-

able height

•  remove the mantel
NOTICE: Surface temperatures 

of  adjacent  walls  and  mantels 

become  hot  during  operation. 

Walls  and  mantels  above  the 

firebox  may  become  hot  to 

the touch. If installed properly, 

these  temperatures  meet  the 

requirement  of  the  national 

product  standard.  Follow  all 

minimum clearances shown in 

this manual.

INSTALLING GAS PIPING TO 

FIREPLACE LOCATION

  WARNING:  This  appliance 

requires  a  3/8"  NPT  (National 

Pipe Thread) inlet connection to 

the pressure regulator.

  WARNING:  A  qualified 

service  person  must  connect 

fireplace to gas supply. Follow 

all local codes.

 CAUTION: Never connect 

propane/LP  fireplace  directly 

to the propane/LP supply. This 

fireplace  requires  an  external 

regulator (not supplied). Install 

the external regulator between 

the  fireplace  and  propane/LP 

supply.

f i r e - p a r t s . c o m

Содержание SVFS32NRK

Страница 1: ...llyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied...

Страница 2: ...from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ven tilation section on page 6 of this manual This appli...

Страница 3: ...lame patterns Ceiling fans can create drafts that alter burner flame patterns Altered burner patterns can cause sooting Due to high temperatures the appliance should be located out oftrafficandawayfro...

Страница 4: ...Figure 1 Log Base Assembly Top Outer Casing Figure 2 Fireplace Log Set Base Assembly Front Burner Depletion Sensing ODS safety shutoff system The ODS shuts down the fire place if enough fresh air is n...

Страница 5: ...Push the bottom corners of the screen in and release The screen will pop out at the bottom Grasp the bottom of the screen lift the screen up and pull out to remove 3 Remove protective packaging appli...

Страница 6: ...ll fireplace plus any adjoining rooms with door less passageways or ventilation grills between the rooms 1 Determine the volume of the space length x width x height Length x Width x Height __________c...

Страница 7: ...dditional fresh air Your options are as follows A Rework worksheet adding the space of an adjoining room If the extra space provides an unconfined space remove door to adjoining room or add ventilatio...

Страница 8: ...nlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two perma nent openings on...

Страница 9: ...ed with the fireplace is to be used it must be wired to a 120 volt supply by a certified electrician OPTIONAL PANELS Each fireplace is shipped with louvered panels installed Smooth panels are also shi...

Страница 10: ...ge 14 9 Route blower electrical cord through ac cess holes in either side of fireplace CONVENTIONAL FIREPLACE INSTALLATION Conventional installation of this fireplace involves installing fireplace alo...

Страница 11: ...INSTALLATION Continued Figure 12 Inserting Fireplace Into Cabinet Mantel BUILT IN FIREPLACE INSTALLATION Built in installation of this fireplace involves installing fireplace into a framed in enclosu...

Страница 12: ...cing WARNING Do not allow any combustiblematerialstooverlap the firebox front facing IMPORTANT Noncombustible materials such as brick tile etc may overlap the front facing but should never cover any n...

Страница 13: ...leet CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume t...

Страница 14: ...erly INSTALLATION Continued Figure 17 External Regulator on Propane LP Supply Tank with Vent Pointing Down External Regulator Propane LP Supply Tank Vent Pointing Down CONNECTING FIREPLACE TO GAS SUPP...

Страница 15: ...exible gas line is provided to allow accessibility fromthefireplace seeFigure20 The flexible gas supply line con nection to the equipment shutoff valve should be accessible CHECKING GAS CONNECTIONS WA...

Страница 16: ...Propane LP Gas Propane LP Supply Tank Figure 22 Checking Gas Joints for Natural Gas Gas Control Valve Equipment Shutoff Valve Equipment Shutoff Valve Gas Meter Gas Control Valve Open Closed Equipment...

Страница 17: ...s to rest against the front of the base assembly Make sure the flame from the ember pan does not touch the ember bed log 5 The left middle log has a groove on the bottom to sit on the chassis and has...

Страница 18: ...ly as shown in Figure 31 9 Place the left top log onto the rear log and the left middle log Make sure to place the projection on the bottom of the left top log into the recessed areas on the rear and...

Страница 19: ...lace when it is placed over a shoulder screw Place the ember chunks as shown in Fig ure 35 on page 20 by placing the ember chunk with the number 1 on the left 2 in the center and 3 on the right These...

Страница 20: ...nk 1 Ember Chunk 2 Ember Chunk 3 Flat Front Burner Figure 38 Installing Fireplace Screen Magnets Screen Bracket 4 Installfireplacescreenbyplacingthescreen brackets on top of the fireplace screen brack...

Страница 21: ...e appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS WARNING Youmustoperate this fireplace with the fireplace screen in place...

Страница 22: ...t a qualified service person or gas supplier for repairs Note If pilot goes out repeat steps 4 through 8 beginning on page 21 9 Slightly push in and turn control knob coun terclockwise to the ON posit...

Страница 23: ...ireplace could pro duce increased levels of carbon monoxide Follow instructions below Yellow flame on rear burner is normal NOTICE Do not mistake orange flames with yellow tipping Dirt or other fine p...

Страница 24: ...amage BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount of air to mix with the gas This provides a clean burning flame Keep these holes clear of dust...

Страница 25: ...in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing...

Страница 26: ...enance page24 or replace burner orifice s 1 Clean burner see Cleaning and Maintenance page 24 or replace burner orifice s 2 Replace damaged burner 3 Replace gas regulator 1 Check burner for dirt and d...

Страница 27: ...1 Replace 9 volt batteries in receiver and remote control 1 Read EMBER PLACE MENT and correct per in structions 2 Replace orifice Call techni cal service 3 Check burner s for dirt and debris If found...

Страница 28: ...nance page 24 1 Locate and correct all leaks see Checking Gas Con nections page 15 2 Replace control valve or gas control 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all lea...

Страница 29: ...PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty When ordering repair parts always give the following information 1 The model...

Страница 30: ...01A 30 PARTS LOG BASE ASSEMBLY MODELS SVFS32NRK SVFS32PRK SVFS36NRK AND SVFS36PRK See page 32 for part numbers 1 2 3 5 29 30 4 7 40 13 21 27 11 10 14 16 15 24 12 36 18 37 38 17 39 35 31 20 32 33 19 2...

Страница 31: ...06 Valve Gas LP 0 820 642 1 15 103784 01 Knob Short Extension Pilot 1 16 103784 02 Knob Short Extension HI LO 1 17 107634 01SA Plate NG Conversion 1 18 111435 04 Ignitor Electronic 1 19 112465 01 Burn...

Страница 32: ...01004 10 Orifice 0453 1 15MM Middle 1 37 111819 10 Orifice Elbow P53 95 110 Pan 1 099056 45 Orifice 0 028 0 711MM Pan 1 111819 11 Orifice Elbow P53 95 300 Pan 1 38 124933 01 Orifice Holder 90 Degree E...

Страница 33: ...Panel Closure Smooth 2 106651 01 Panel Closure Smooth 2 2 108423 02 Panel Face Top 32 Stamped 2 106684 01 Panel Closure Top Louvered 36 2 3 110037 01 Electrical Duct Assembly 1 4 20280 Spacer Top 4 5...

Страница 34: ...Middle 1 7 125851 07 125852 07 Log Right Middle 1 8 125851 08 125852 08 Log Rear Middle 1 9 125851 09 125852 09 Log Rear 1 10 125851 10 125851 10 Log Left Top 1 11 125851 11 125852 11 Log Middle Cros...

Страница 35: ...r unfinished mantel or wall open ing edges etc BRICK LINER KITS SBLQ32SVF 32 Brick Liner Kit SBLQ36SVF 36 Brick Liner Kit NOTICE All accessories may not be available for all fireplace models Purchase...

Страница 36: ...126543 01 Rev A 07 13 1508 Elm Hill Pike Suite 108 Nashville TN 37210 www lennoxhearthproducts com fire parts com...

Отзывы: