NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.

10

ACCESSORIES AND COMPONENTS

Brass

AC-SPB

Adjustable Canopy

Black

AC-BK

40HTK-SPB

Horizontal Trim Kits

45HTK-SPB

Forced Air Kit
(Includes Variable
Speed Wall Switch)

FAB-1600

Grounded

to Appliance

Blower Motor

Motor Plug

Receptacle

120V

Appliance Junction Box

NOTE:  If any of the original wire as supplied
must be replaced, it must be replaced with type
AWM 105

°

c  – 18Ga. wire

Figure 18

Trim Kits

The UVFCE fireboxes can be enhanced with
stylish trim kits, Models 40 HTK-SPB and
45HTK-SPB. Refer to the installation instruc-
tions provided with the trim kits for installation
details.

Forced Air Kit

If you are installing the forced air kit, Model
FAB-1600, see the installation instructions pro-
vided with the kit for electrical wiring require-
ments (

Figure 18 ). The firebox must be con-

nected to main power supply at time of instal-
lation if a forced air kit is to be installed later.
The electrical connections must be made be-
fore the firebox is framed and enclosed in the
finished walls.

This appliance must be electrically grounded in
accordance with local codes or, in the absence
of local codes, the national electrical code,
ANSI/NFPA 70 - (Latest Edition).

CAUTION: ELECTRICAL CONNECTIONS
SHOULD ONLY BE PERFORMED BY A QUALI-
FIED, LICENSED ELECTRICIAN. MAIN POWER
MUST BE OFF WHEN CONNECTING TO MAIN
ELECTRICAL POWER SUPPLY OR PERFORM-
ING SERVICE.

FIREBOX FINISHES

There are a wide variety of “finished looks” for
your UVFCE built-in unvented fireboxes from
formal wall decor with elaborate mantels to
rustic wood paneling or warm brick facings.

Only noncombustible materials like marble,
stone, tile, brick, etc. may overlap the black
front facing but be sure not to block the upper
or lower grilles.  Seal all joints between the
black facing and wall surrounds to prevent air
intrusion. Use noncombustible caulking mate-
rial only to seal the black metal facing to the
surround material on the finished wall.

REPLACEMENT PARTS

An exploded view of the firebox with num-
bered parts and a replacement parts list can be
found on page 11. Normally, all parts should
be ordered through your distributor or dealer.
Parts will be shipped at prevailing prices at
time of order.

When ordering repair parts, always give the
following information:

1. The model number of the firebox.
2. The serial number of the firebox.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the firebox.

If you encounter any problems or have any
questions concerning the installation of a un-
vented heater in this system, please contact
your distributor. For the name of your nearest
distributor contact:

Lennox Hearth Products
1110 West Taft Avenue
Orange, California 92865

Содержание STANDARD UVFCE Series

Страница 1: ... LIFE WARNING IMPROPER INSTALLATION ADJUSTMENT AL TERATION SERVICE OR MAINTENANCE CAN CAUSE IN JURY OR PROPERTY DAMAGE REFER TO THIS MANUAL FOR ASSISTANCE OR ADDITIONAL INFORMATION CON SULT A QUALIFIED INSTALLER SERVICE AGENCY OR THE GAS SUPPLIER WARNING DO NOT BURN WOOD OR OTHER MATERIAL IN THESE APPLIANCES CAREFULLY REVIEW THE INSTRUCTIONS SUPPLIED WITH THE DECORATIVE TYPE UNVENTED ROOM HEATER F...

Страница 2: ...LTING IN SERIOUS IN JURY AND OR PROPERTY DAMAGE WARNING ANY CHANGE TO THIS UN VENTED ROOM HEATER CAN BE DAN GEROUS IMPROPER INSTALLATION OR USE OF THIS HEATER CAN CAUSE SERI OUS INJURY OR DEATH FROM FIRE BURNS EXPLOSION OR CARBON MON OXIDE POISONING The UVFCE Series are unvented fireboxes They feature a self contained heat circulating system This installation manual will enable you to obtain a saf...

Страница 3: ...nt Free heater _______ BTU Hr Gas appliance 1 _______ BTU Hr Gas appliance 2 _______ BTU Hr Total _______ BTU Hr Example Vent free heater 26 000 BTU Hr Gas appliance 1 40 000 BTU Hr water heater Total 66 000 BTU Hr Do not include direct vent gas appliances Direct vent is sealed combustion and draws combustion air from the outdoors 4 ComparethemaximumBTU Hrthespacecan support with the actual amount...

Страница 4: ...CURRENTS MOVE HEAT TO WALLSURFACESNEXTTOHEATER INSTALL INGHEATERNEXTTOVINYLORCLOTHWALL COVERINGS OR OPERATING HEATER WHERE IMPURITIES IN THE AIR SUCH AS TOBACCO SMOKE EXISTS MAY DISCOLOR WALLS WARNING DO NOT ALLOW FANS TO BLOW DIRECTLY INTO THE FIREPLACE AVOID ANY DRAFTS THAT ALTER BURNER FLAME PATTERNS WARNING DO NOT USE A BLOWER IN SERT HEAT EXCHANGER INSERT OR OTHER ACCESSORY NOT APPROVED FOR U...

Страница 5: ...side of the firebox Connect the gas line before the firebox is enclosed in the fin ished wall The gas knockout is determined by a 1 round indentation located at the bottom and slightly off center in the side refractories THE KNOCK OUT IS ALWAYS REMOVED FROM INSIDE THE FIREBOX If removal is attempted from the outer wrapper side re fractory damage may occur With a medium sized hammer lightly tap the...

Страница 6: ...dmaterialssuchasmarble brick stone etc to be installed 2 Measure the square footage of the floor space to be occupied by the system and sur rounds 3 Note the floor construction i e 2 x 6 s 2 x 8 s or 2 x 10 s single or double joists type and thickness of floor boards 4 Use this information and consult your local building code to determine if you need addi tional support CAUTION DO NOT BLOCK THE HE...

Страница 7: ...NOT TO SCALE 7 FIREBOX SPECIFICATIONS Figure 8 40 40 45 45 7 21 40 38 45 42 1 1 1 4 6 34 34 21 38 21 40 29 45 33 40 40 45 45 UVFCE Front View Left Side View Top View 34 Gas Line Knockout J Box Cover 3 8 21 38 8 3 Right Side View ...

Страница 8: ...ing Face Unfinished Shown A G C Back Wall Of Chase Enclosure Including Finishing Materials If Any Rough Framing Face Unfinished Shown C A G H H Back Wall Of Chase Enclosure Including Finishing Materials If Any Rough Framing Face Unfinished Shown Figure 9 Figure 10 Figure 11 Figure 12 Opening 40 45 A 40 45 B 39 39 C 29 33 D 14 16 E 71 76 F 35 38 G 21 21 H 8 8 J 50 54 Framing Dimensions ...

Страница 9: ...nventedfireboxes Refertotheinstal lation instructions provided with the canopy for installation details Space Maintain Air Space at Back and Sides Combustible Wall Space Floor Optional Hearth Extension Platform Maintain Air Space at Back and Sides Combustible Wall 3 Screws for 40 Models 4 Screws for 45 Models Canopy Firebox Opening Step 4 Firebox may be anchored to floor Bend downfour 4 anchortabs...

Страница 10: ...QUALI FIED LICENSEDELECTRICIAN MAINPOWER MUST BE OFF WHEN CONNECTING TO MAIN ELECTRICAL POWER SUPPLY OR PERFORM ING SERVICE FIREBOX FINISHES There are a wide variety of finished looks for your UVFCE built in unvented fireboxes from formal wall decor with elaborate mantels to rustic wood paneling or warm brick facings Only noncombustible materials like marble stone tile brick etc may overlap the bl...

Страница 11: ...5 No Description Part No Part No 1 Side Refractory Right 026042 026042 2 Side Refractory Left 026041 026041 3 Bottom Refractory 044991 044992 4 Rear Refractory 026021 026022 5 Screen Panel 099648 099649 6 Screen Rod 2 011382 010234 7 Canopy 054291 054300 8 Gas Line 096908 096908 9 Nipple 000802 000802 ...

Страница 12: ...amage to the Unvented Gas Room Heater will produce unsafe levels of carbon monoxide and will result in a fire hazard LIMITATION ON LIABILITY It is expressly agreed and understood that LHP s sole obligation and purchaser s exclusive remedy under this warranty under any other warranty expressed or implied or in contract tort or otherwise shall be limited to replacement repair or refund as specified ...

Отзывы: