background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

3

New York City, New York (MEA)

Installation of these fi replaces are approved 
for installation in New York City in the US state 
of New York.

These appliances and their individual shut-off 
valves 

must be disconnected

 from the gas 

supply piping system during any pressure 
testing of that system at pressures 

greater 

than

 1/2 psig (3.5 kPa)

.

These appliances must be isolated from the 
gas supply piping system (

by closing their 

individual manual shut-off valve

) during any 

pressure testing of the gas supply piping 
system at test pressures equal to or 

less than 

1/2 psig (3.5 kPa).

Orifi ce Sizes -  Sea Level to High Altitude
(All Models)

These appliances are tested and approved for 
installation at elevations of 0-4500 feet (0-1372 
meters) above sea level using the standard 
burner orifice sizes (marked with an "*" in 

Table 7

)

.  For elevations above 4500 feet, 

contact your gas supplier or qualifi ed service 
technician . Install the appliance according to 
the regulations of the local authorities having 
jurisdiction and, in the USA, the National Fuel 
Gas Code NFPA 54 / ANSI Z223.1 - latest edition 
or, in Canada, the CAN1-B149.1 and .2 codes 
- latest edition.

 Input (BTU) Manually-Modulated Gas 

Valves (millivolt models)

* PROPANE GAS

Models

Input Rate (BTU / HR)

SSDV-3530CPM

23,000 high

17,500 low

SSDV-4035CPM

29,000 high

22,500 low

Table 2

Electronic Models 

Electronic models have a fi xed rate gas valve.
Input of electronic models is shown in 

Table 3.

Electronic Models with Fixed Rate Gas Valve

Natural and Propane Gas

Model Series

Input Rate (BTU / HR)

SSDV-3530

23,000 

SSDV-4035

29,000 

Table 3

Inlet Gas Supply Pressure 

(all models)

Fuel #

Minimum

Maximum

Natural Gas

5.0" WC

(1.24 kPa)

10.5" WC

(2.61 kPa)

Propane

11.0" WC

(2.74 kPa)

13.0" WC

(3.23 kPa)

Table 4

Gas Pressure - All Models

Tables 4, 5 and 6  

show the appliances'  gas 

pressure requirements:

Manifold Gas Supply Pressure

(millivolt models)

Fuel #

Low

High

Natural 

Gas

(Lo) 2.2" WC

(.55 kPa)

(Hi) 3.5" WC

(.87 kPa)

Propane

(Lo) 6.3" WC

(1.57 kPa)

(Hi) 10.0" WC

(2.49 kPa)

Table 5

Test gauge connections are provided on the 
front of the millivolt gas control valve, identi-
fi ed IN for the inlet and OUT for the manifold 
side.  A 1/8" NPT Test gauge connection 
is provided at the inlet and outlet side of 

 

the electronic gas control valve.

Burner Orifi ce Sizes 

Elevation 0-4500 feet ( 0-1372 meters)

Model
Series

Natural

Gas

drill size 

(inches)

Propane

Gas

drill size (inches)

SSDV-3530

2.3 mm (.090") 

*

37L70 •

#54 (.055") 

*

99K79 •

SSDV-4035

#36 (.1065") 

*

18L4001 •

#52 (.0635")

*

LB-55874D •

* Standard size installed at factory
•  Part /Cat. Number

Table 7

Manifold Gas Supply Pressure

(electronic models)

Fuel #

Max. Manifold Pressure

Natural Gas

(Hi) 3.5" WC (.87 kPa)

Propane

(Hi) 10.0" WC (2.49 kPa)

Table 6

* If fi eld converted - see 

Page

s 35-37

 Input (BTU) Manually-Modulated Gas 

Valves (millivolt models)

NATURAL GAS

Models

Input Rate (BTU / HR)

SSDV-3530CNM

23,000 high

17,500 low

SSDV-4035CNM

29,000 high

21,500 low

Table 1

HI

LO W

HT

PT

HT

PT

PILO

T

PIL

O

T

ON

it

OFF

IN

OUT

Manifold Pressure Tap

Inlet Pressure Tap

SIT Millivolt  Gas Valve

Pilot Adjustment
Screw

HI/LO Variable 
Flame Height 
Adjustment

Main Gas 

Control Knob

OFF/PILOT/ON

Figure 1

Figure 3

Honeywell Electronic  Gas Valve

F

F

O

NI

P

S

I

N

O

L

O

R

T

N

O

C

GI

N
TI

ER

Manifold Pressure 
Port

ON / OFF Switch

Inlet 
Pressure
Port

Electronic Gas 
Control Valve

O

N

OF

F

PI

LOT

L

O

H

I

Figure 2

GAS CONTROL
KNOB

CONVERTIBLE
HI/LO REGULATOR
(adjusts fl ame height
and heat output)

INLET
PRESSURE
TAP

PILOT
ADJUSTMENT 
SCREW

WIRING
TERM-
INALS

OUTLET
PRESSURE
TAP

TP/TH

PIEZO 
IGNITER

TH

TP

Honeywell Millivolt  Gas Valve

Содержание SSDVR-3530CNE

Страница 1: ...T light any appliance DO NOT touch any electrical switches Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow your gas suppliers instructions If yo...

Страница 2: ...oms and Manufactured Homes Manufactured Homes See Manufactured Home Requirements on Page 7 for additional information PACKAGING The assembled vented gas fireplace heater is packaged with 1 One log set...

Страница 3: ...kPa 10 5 WC 2 61 kPa Propane 11 0 WC 2 74 kPa 13 0 WC 3 23 kPa Table 4 Gas Pressure All Models Tables 4 5 and 6 show the appliances gas pressure requirements Manifold Gas Supply Pressure millivolt mod...

Страница 4: ...zontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS Inspection The...

Страница 5: ...ionsin Homeowner s Manual WARNING Carbon monoxide poisoning early signs of carbon monoxide poisoning are similar to the flu withheadaches dizzinessand or nausea If you have these signs obtainfreshairi...

Страница 6: ...elveslikethesearecommonlyusedforlocat ing television sets and decorative plants Be awarethatthisisaheatproducingappliance Objects placed above the unit are exposed to elevated temperatures To provide...

Страница 7: ...mm or less See Figure 6 For projections exceeding 2 1 2 64 mm see Figure 6 For additional vent location restrictions refer to Figure 7 on Page 8 Figure 6 Side Elevation View Note See Figure 33 on Pag...

Страница 8: ...e meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly I Clearance to service...

Страница 9: ...w of Fireplace 45 o At 14 minimum side wall clearance a combustible wall can project to any length Protected wall shown in white Inches millimeters Figure 10 At 8 1 4 side wall clearance a combustible...

Страница 10: ...ot factory provided and bringinelectricalservicelineforforcedair circulating blower optional equipment b ElectronicAppliances Fieldwireandinstall operating control switch Step 5 Page 25 Install blower...

Страница 11: ...re top vent only Louvered Front Model Shown Rear vent models only Electrical Inlet 2 3 4 x 2 70 x 51 Cover Plate W Knockout Right Side View 9 229 E B D C Front View 3 76 A 1 3 8 35 Optional ELECTRICAL...

Страница 12: ...be aware that if tank size is too small i e under 100 lbs if this is the only gas appliance in the dwelling Ref NPFA 58 there may be loss of pressure resulting in insufficient fuel delivery which can...

Страница 13: ...appliance The vent pipe is tested to be run inside an enclosing wall such as a chase There is no requirement for inspection openings in the enclosing wall at any of the joints in the vent pipe WARNIN...

Страница 14: ...0 3 9 6 5 7 5 0 0 0 2 0 2 2 7 6 1 0 3 0 0 4 5 3 7 5 2 1 6 1 0 0 2 0 3 5 9 7 5 2 6 6 0 1 0 2 0 3 1 8 5 7 6 0 0 0 1 1 2 0 9 5 7 0 2 1 0 1 4 5 1 9 5 2 6 7 0 0 2 0 1 3 3 9 5 7 7 0 0 0 0 2 2 6 9 8 1 0 1 2...

Страница 15: ...ectinglengthcombinations Elbowsare available in 90 and 45 configurations Refer to Figure 22 on Page 16 for the SV4 5E45 and SV4 5E90 elbow dimensional specifications Where required a telescopic vent s...

Страница 16: ...the center axis of their initial collar section to align with the required direction of the next vent run element Twist elbow sections in a clockwise direction only so as to avoid the possiblity of un...

Страница 17: ...usingSecureFlex useFirestop Spacer SF4 5VF Ceiling Firestop Spacer SV4 5VF Ceiling Firestop Spacer SV4 5VF Wall Firestop Spacer SV4 5HF When using Secure Flex use Firestop Spacer SF4 5VF When using Se...

Страница 18: ...restop Spacer SF4 5HF Figure 29 Rear Vent THREE ELBOWS Figure 30 Top Vent THREE ELBOWS VERTICAL VENT FIGURES TABLES CONTINUED HORIZONTAL OUTSIDE WALL TERMINATION SYSTEM Figure 31 and Figures 34 to 40...

Страница 19: ...ush the vent component against the previous section until it fully engages then twist the componentclockwiserunningthedimplesdown and along the incline channels until they seat at the end of the chann...

Страница 20: ...Termination J Assemble vent run to exterior wall If not previously measured locate the center of the vent at the exterior wall Prepare an opening as described in Step B Assemble the vent system topoin...

Страница 21: ...CCEPTABLE AS 1 FOOT OF VERTICAL RISE EXCEPT WHERE AN ELBOW IS THE ONLY VERTICAL COMPONENT IN THE SYSTEM See Figure 35 See Table 12 as an aid in venting component selection for a particular range of ex...

Страница 22: ...ee Table 12 on Page 21 as an aid in venting component selection for a particular range of exterior wall thicknesses HORIZONTAL VENT FIGURES TABLES CONTINUED Table H H H1 Maximum HMaximum V Minimum fee...

Страница 23: ...of horizontal run up to a maximum total H H1 H2 horizontal run of 20 feet Figure 40 Top Vent THREE 90 DEGREE ELBOWS Figure 39 Rear Vent THREE 90 DEGREE ELBOWS See Table 12 on Page 21 as an aid in ven...

Страница 24: ...sely around the inner flexible vent pipe push it back out of the way 2 ApplyabeadofMill PacBlack 700 F high temperature sealant Catalog No 10K81 to the inner adapter collar approximately 1 2 inch from...

Страница 25: ...ed Electrical power must be connectedtoeitherofthesereceptaclesinorder to operate these blowers Install the blower kits according to the installation instructions provided with the kits 3 Wire the con...

Страница 26: ...s the National Electrical Code ANSI NFPA 70 latest edition In Canada the current CSA C22 1 Canadian Electrical Code Step 6 CONNECTING GAS LINE Make gas line connections All codes require a shut offval...

Страница 27: ...er HI LO flame adjustment knob and pilot and main gas OFF ON control knob are located below the glass panel enclosure The gas valve for electronic systems is also located below the glass enclosure pan...

Страница 28: ...sts on the subfloor 5 Placethetoprightlog D asshown Thetop fork on log D fits into notch on log A as shown The bottom fork on log D rests on subfloor flange identified in photo 1 SSDV 4035 Install as...

Страница 29: ...Item letters above correspond to photos B C D A A Notch Notch 2 C 3 Notchesonbottomoflog C fitsover2locatingbrackets Topforkonlog B fitsintonotchonlog A B A 4 D A 5 Topforkonlog D fitsintonotchonlog A...

Страница 30: ...MODEL SSDV 4035 Log Placement Instructions D A 4 A Bottomoflog B restsonsubfloor B Topforkonlog D fitsintonotchonlog A asshown Topforkonlog B fitsintonotchonlog A as shown 1 Place Embers and Volcanic...

Страница 31: ...glass door of this appli ance must only be replaced as a complete unit as provided by themanufacturer Donotattempt to replace broken cracked or chipped glass separately WARNING Do not attempt to touch...

Страница 32: ...ll Figure 58 See Page 6 for Cold Climate Insulation and Page 9 for Clearances Burner Air Shutter Adjustment Procedure CAUTION Theairshutterdoorandnearbyappliancesurfacesare hot Exercise caution to avo...

Страница 33: ...L76 SV4 5E45 45 Degree Elbow 5 77L77 SV4 5E90 90 Degree Elbow 3 4 5 6 7 10 1 8 9 11 INSTALLATION ACCESSORIES The following flashings come packaged with a storm collar 6 77L78 SV4 5F Flat Roof Flashing...

Страница 34: ...Sealant Bulk 12 pack 23 91L66 SF GC4 6 Gear Clamp 4 5 in 114 mm for flex 6 pieces 23 91L67 SF GC7 6 Gear Clamp 7 5 in 190 5 mm for flex 6 pieces 24 99L02 SV4 5HRK14 Horizontal Riser Kit 14 24 99L03 SV...

Страница 35: ...qualified service agency performing thisinstallationassumesresponsibil ity for this conversion AVERTISSEMENT Cet quipement de conversion sera install par une agence qualifi e de service conform ment a...

Страница 36: ...ning it clockwise Replace the plastic protecting cap Pilot for Honeywell Millivolt Gas Valve Loosening of Hex Fitting For Orifice Strip Tab Positioning Figure 63 7 16 in Open End Wrench Hood Hood Alig...

Страница 37: ...emove the slotted cap screw o ring pressure regulating adjusting screw and spring Retain all parts for possible later use Install new components from the kit Black cap and red spring for propane gas u...

Страница 38: ...NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE 38 NOTES...

Страница 39: ...NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE 39 NOTES...

Страница 40: ...CA 92865 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your...

Отзывы: