NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

25

       

CAUTION

Ensure that wires are positioned 
away from  hot surfaces and sharp 
edges.

       

CAUTION

Do not connect the optional wall 
switch for burner operation  to a 
120 Volt AC power supply.

     

CAUTION

Label all wires prior to disconnection 
when servicing controls.  Wiring 
errors can cause improper and dan-
gerous appliance operation.

Step 4. FIELD WIRING 

Refer to Section A for millivolt appliances and 
Section B for electronic appliances. The gas 
valve is set in place and pre-wired at the factory 
on both models.

A. SIT and Honeywell Millivolt Wiring 

(See Figure 43) 

 

1

.  Select  any of the following optional controls: 

appliance-mounted (rocker switch) or wall-
mounted  switch, wall thermostat, or the 
standard or deluxe remote control kits. If ap-
pliance-mounted ON/OFF control is selected 
mount it in the gas valve mounting bracket. 

2

. If wall-mounted ON/OFF control or ther-

mostat is selected mount it in a convenient 
location on a wall near the fi replace.

Figure 43 -

 SIT & HONEYWELL Millivolt Wiring Diagram

3. 

Connect the power supply wires  (including 
the ground supply wire) as shown in 

Figures 

44 & 45

.  (If the fi eld-provided J-box/outlet 

box is being used, all of the outlet box wiring 
must be fi eld-provided). 

4.

 Locate and install a low voltage (24V) wall-

mounted switch or thermostat (both fi eld-
provided)in the desired location. 

5. 

Connect the low voltage wire, located inside 
the control compartment, to the wall-mounted 
switch or thermostat.

 Note: 

The supplied 15 feet of 2 conductor wire 

has one end of each conductor connected to 
the gas valve circuit and the other end of each 
conductor  placed loose inside the control 
compartment. 

6.

 Insert the control circuit plug into the un-

switched receptacle of the outlet box.

7. 

After wiring is complete, mount the outlet box 

to the J-Box.

Note: 

The gas valve-mounted ON/OFF switch  is 

shown in 

Figure 45

. It is integral with the gas 

valve and should be set to the ON position.

 

Step 5.

 

WIRING - OPTIONAL FORCED AIR 

BLOWER KIT

 

FBK-100, FBK-200 and FBK250 Kits 

(See Figure 45) - 

An electrical outlet box (receptacle) is factory 
-provided for the installation of the 

FBK-100

FBK-200 and FBK-250

 forced air blower kits. 

(An optional fi eld-provided outletbox/J-Box 
may also be used.  Electrical power must be 
connected to either of these receptacles in order 
to operate these blowers. Install the blower 
kits according to the installation instructions 
provided with the kits.

3

. Wire the control within the millivolt control 

circuit  using the 15 feet of 2 conductor wire 
supplied with the unit .

 Caution:  do not 

connect the optional wall switch to a 120V 
power supply.

4.

  Alternatively, the appliance may be operated 

without the use of the controls indicated in 

Step 1

, solely  by manipulating the gas valve 

control knob. In order to use this method, 
twist the free ends of the two conductor wire 
(which would otherwise go to the standard 
ON/OFF switch or Optional Switch) together 
as shown in 

Figure 43

.

 

Note:

 Wire is located inside the control 

compartment  

Note:

 The supplied 15 feet of 2 conductor wire 

has one end of each conductor connected to 
the gas valve circuit and the other end of each 
conductor  placed loose inside the control 
compartment. 

B. Electronic Wiring 

(See Figure 45)

 – 

Note: 

The electronic appliance must be con-

nected to the main power supply.

The junction box is located on the right side of 
the appliance. It contains a factory installed and 
wired outlet box (duplex receptacle). Also, an 
optional fi eld-provided junction box with recep-
tacle may be installed at the front of the control 
compartment on either side of the cabinet.

 See 

Figure 44. 

It will be held in place by a conduit 

fi tting and locknut (fi eld-provided).

1.

  Route a 3-wire 120Vac 60Hz 1ph power supply 

to the appliance junction box.

2. 

If the factory-provided outlet/junction box at 
the right rear of the fi replace is being used, 
remove the outlet box from the junction box 
by removing two screws.

Figure 44

See

 Figure 14

 on 

Page 

11

for Optional Electrical
Inlet Knockout Location

*Field-Provided 

Junction Box 

and Duplex 
Receptacle

*Narrow (2 1/8" Wide) 
J-Box Required

Optional J-Box/Outlet 
Box (Left Side Shown)

Field Wired

Factory 
Wired

TH

TP

TH

TP

 

 

 

 

* Optional 
Control Switch

Thermopile

Schematic
Representation
Only

•  If any of the original wire as supplied must 
be replaced, it must be replaced with Type AWM 
105 C - 18 gage wire.
*  Optional Kits Installed - ON/OFF  wall switch, unit mounted burner ON/OFF switch, wall thermostat or 
remote control.receiver. 

P

T

*

* Twist wires together to operate unit 
solely by manipulating the gas valve 
control knob; or connect wires to 
optional control switch (wall switch, 
remote control or wall thermostat to 
operate unit.

Содержание SSDVR-3530CNE

Страница 1: ...T light any appliance DO NOT touch any electrical switches Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow your gas suppliers instructions If yo...

Страница 2: ...oms and Manufactured Homes Manufactured Homes See Manufactured Home Requirements on Page 7 for additional information PACKAGING The assembled vented gas fireplace heater is packaged with 1 One log set...

Страница 3: ...kPa 10 5 WC 2 61 kPa Propane 11 0 WC 2 74 kPa 13 0 WC 3 23 kPa Table 4 Gas Pressure All Models Tables 4 5 and 6 show the appliances gas pressure requirements Manifold Gas Supply Pressure millivolt mod...

Страница 4: ...zontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS Inspection The...

Страница 5: ...ionsin Homeowner s Manual WARNING Carbon monoxide poisoning early signs of carbon monoxide poisoning are similar to the flu withheadaches dizzinessand or nausea If you have these signs obtainfreshairi...

Страница 6: ...elveslikethesearecommonlyusedforlocat ing television sets and decorative plants Be awarethatthisisaheatproducingappliance Objects placed above the unit are exposed to elevated temperatures To provide...

Страница 7: ...mm or less See Figure 6 For projections exceeding 2 1 2 64 mm see Figure 6 For additional vent location restrictions refer to Figure 7 on Page 8 Figure 6 Side Elevation View Note See Figure 33 on Pag...

Страница 8: ...e meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly I Clearance to service...

Страница 9: ...w of Fireplace 45 o At 14 minimum side wall clearance a combustible wall can project to any length Protected wall shown in white Inches millimeters Figure 10 At 8 1 4 side wall clearance a combustible...

Страница 10: ...ot factory provided and bringinelectricalservicelineforforcedair circulating blower optional equipment b ElectronicAppliances Fieldwireandinstall operating control switch Step 5 Page 25 Install blower...

Страница 11: ...re top vent only Louvered Front Model Shown Rear vent models only Electrical Inlet 2 3 4 x 2 70 x 51 Cover Plate W Knockout Right Side View 9 229 E B D C Front View 3 76 A 1 3 8 35 Optional ELECTRICAL...

Страница 12: ...be aware that if tank size is too small i e under 100 lbs if this is the only gas appliance in the dwelling Ref NPFA 58 there may be loss of pressure resulting in insufficient fuel delivery which can...

Страница 13: ...appliance The vent pipe is tested to be run inside an enclosing wall such as a chase There is no requirement for inspection openings in the enclosing wall at any of the joints in the vent pipe WARNIN...

Страница 14: ...0 3 9 6 5 7 5 0 0 0 2 0 2 2 7 6 1 0 3 0 0 4 5 3 7 5 2 1 6 1 0 0 2 0 3 5 9 7 5 2 6 6 0 1 0 2 0 3 1 8 5 7 6 0 0 0 1 1 2 0 9 5 7 0 2 1 0 1 4 5 1 9 5 2 6 7 0 0 2 0 1 3 3 9 5 7 7 0 0 0 0 2 2 6 9 8 1 0 1 2...

Страница 15: ...ectinglengthcombinations Elbowsare available in 90 and 45 configurations Refer to Figure 22 on Page 16 for the SV4 5E45 and SV4 5E90 elbow dimensional specifications Where required a telescopic vent s...

Страница 16: ...the center axis of their initial collar section to align with the required direction of the next vent run element Twist elbow sections in a clockwise direction only so as to avoid the possiblity of un...

Страница 17: ...usingSecureFlex useFirestop Spacer SF4 5VF Ceiling Firestop Spacer SV4 5VF Ceiling Firestop Spacer SV4 5VF Wall Firestop Spacer SV4 5HF When using Secure Flex use Firestop Spacer SF4 5VF When using Se...

Страница 18: ...restop Spacer SF4 5HF Figure 29 Rear Vent THREE ELBOWS Figure 30 Top Vent THREE ELBOWS VERTICAL VENT FIGURES TABLES CONTINUED HORIZONTAL OUTSIDE WALL TERMINATION SYSTEM Figure 31 and Figures 34 to 40...

Страница 19: ...ush the vent component against the previous section until it fully engages then twist the componentclockwiserunningthedimplesdown and along the incline channels until they seat at the end of the chann...

Страница 20: ...Termination J Assemble vent run to exterior wall If not previously measured locate the center of the vent at the exterior wall Prepare an opening as described in Step B Assemble the vent system topoin...

Страница 21: ...CCEPTABLE AS 1 FOOT OF VERTICAL RISE EXCEPT WHERE AN ELBOW IS THE ONLY VERTICAL COMPONENT IN THE SYSTEM See Figure 35 See Table 12 as an aid in venting component selection for a particular range of ex...

Страница 22: ...ee Table 12 on Page 21 as an aid in venting component selection for a particular range of exterior wall thicknesses HORIZONTAL VENT FIGURES TABLES CONTINUED Table H H H1 Maximum HMaximum V Minimum fee...

Страница 23: ...of horizontal run up to a maximum total H H1 H2 horizontal run of 20 feet Figure 40 Top Vent THREE 90 DEGREE ELBOWS Figure 39 Rear Vent THREE 90 DEGREE ELBOWS See Table 12 on Page 21 as an aid in ven...

Страница 24: ...sely around the inner flexible vent pipe push it back out of the way 2 ApplyabeadofMill PacBlack 700 F high temperature sealant Catalog No 10K81 to the inner adapter collar approximately 1 2 inch from...

Страница 25: ...ed Electrical power must be connectedtoeitherofthesereceptaclesinorder to operate these blowers Install the blower kits according to the installation instructions provided with the kits 3 Wire the con...

Страница 26: ...s the National Electrical Code ANSI NFPA 70 latest edition In Canada the current CSA C22 1 Canadian Electrical Code Step 6 CONNECTING GAS LINE Make gas line connections All codes require a shut offval...

Страница 27: ...er HI LO flame adjustment knob and pilot and main gas OFF ON control knob are located below the glass panel enclosure The gas valve for electronic systems is also located below the glass enclosure pan...

Страница 28: ...sts on the subfloor 5 Placethetoprightlog D asshown Thetop fork on log D fits into notch on log A as shown The bottom fork on log D rests on subfloor flange identified in photo 1 SSDV 4035 Install as...

Страница 29: ...Item letters above correspond to photos B C D A A Notch Notch 2 C 3 Notchesonbottomoflog C fitsover2locatingbrackets Topforkonlog B fitsintonotchonlog A B A 4 D A 5 Topforkonlog D fitsintonotchonlog A...

Страница 30: ...MODEL SSDV 4035 Log Placement Instructions D A 4 A Bottomoflog B restsonsubfloor B Topforkonlog D fitsintonotchonlog A asshown Topforkonlog B fitsintonotchonlog A as shown 1 Place Embers and Volcanic...

Страница 31: ...glass door of this appli ance must only be replaced as a complete unit as provided by themanufacturer Donotattempt to replace broken cracked or chipped glass separately WARNING Do not attempt to touch...

Страница 32: ...ll Figure 58 See Page 6 for Cold Climate Insulation and Page 9 for Clearances Burner Air Shutter Adjustment Procedure CAUTION Theairshutterdoorandnearbyappliancesurfacesare hot Exercise caution to avo...

Страница 33: ...L76 SV4 5E45 45 Degree Elbow 5 77L77 SV4 5E90 90 Degree Elbow 3 4 5 6 7 10 1 8 9 11 INSTALLATION ACCESSORIES The following flashings come packaged with a storm collar 6 77L78 SV4 5F Flat Roof Flashing...

Страница 34: ...Sealant Bulk 12 pack 23 91L66 SF GC4 6 Gear Clamp 4 5 in 114 mm for flex 6 pieces 23 91L67 SF GC7 6 Gear Clamp 7 5 in 190 5 mm for flex 6 pieces 24 99L02 SV4 5HRK14 Horizontal Riser Kit 14 24 99L03 SV...

Страница 35: ...qualified service agency performing thisinstallationassumesresponsibil ity for this conversion AVERTISSEMENT Cet quipement de conversion sera install par une agence qualifi e de service conform ment a...

Страница 36: ...ning it clockwise Replace the plastic protecting cap Pilot for Honeywell Millivolt Gas Valve Loosening of Hex Fitting For Orifice Strip Tab Positioning Figure 63 7 16 in Open End Wrench Hood Hood Alig...

Страница 37: ...emove the slotted cap screw o ring pressure regulating adjusting screw and spring Retain all parts for possible later use Install new components from the kit Black cap and red spring for propane gas u...

Страница 38: ...NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE 38 NOTES...

Страница 39: ...NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE 39 NOTES...

Страница 40: ...CA 92865 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your...

Отзывы: