Superior SLBV 35 Скачать руководство пользователя страница 24

24

SUPERIOR

®

 B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 •  CARE AND OPERATION INSTRUCTIONS

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

LIGHTING INSTRUCTIONS  -  ELECTRONIC

1.  Slide the switch on the receiver, wall switch or ON/OFF 

switch to "OFF.

2.  (if applicable) Press ON/OFF button on remote control 

transmitter to "OFF."

P/N 580491-01, REV. 01

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing 

property damage, personal injury or loss of life. 

A. This appliance is equipped with an ignition device which 

automatically lights the pilot. Do not try to light the pilot by 

hand.

B. BEFORE OPERATING smell all around the appliance area for 

gas. Be sure to smell next to the floor because some gas is 

heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

•  Do not try to light any appliance.

•  Do not touch any electric switch; do not use any phone in your 

building.

OPERATING INSTRUCTIONS

TO TURN OFF GAS TO APPLIANCE

WARNING

HOT GLASS WILL  CAUSE BURNS.

DO NOT TOUCH GLASS  UNTIL COOLED.

NEVER ALLOW CHILDREN TO TOUCH GLASS.

•  Immediately call your gas supplier from a neighbor’s phone. 

Follow the gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire department.

C. If any portion of this appliance does not operate as the 

instructions indicate, do not try to repair it, call a qualified 

service technician.  Do not use tools.  Force or attempted 

repair may result in a fire or explosion.

D. Do not use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect the 

appliance and to replace any part of the control system and 

any gas control which has been under water.

Electronic Gas Control 

Valve - SIT

Electronic Pilot Assembly

3.  Turn off all electric power to the appliance if service is to 

be performed. Note: The control may have a battery backup 

(remove batteries, if installed).

4.  Close the main line gas shut-off valve.

1.  STOP! Read the safety information above on this label.

2.  Read the Care and Operation manual including the section on 

"Remote Control System," (if applicable).

3.  Slide the switch on the receiver, wall switch or ON/OFF switch to 

"OFF."

4.  Turn "OFF" all electric power to the appliance. Note: The control 

may have a battery backup (remove batteries, if installed).

5.  This appliance is equipped with an ignition device which 

automatically lights the pilot.  Do not try to light the pilot by hand.

6.  Wait five (5) minutes to clear out any gas. Then smell for gas, 

including near the floor. If you smell gas, STOP! Follow “B” in the 

safety information above on this label. If you don’t smell gas, go 

to the next step.

7.  Turn on all electric power to the appliance. Note: The control may 

have a battery backup (install batteries, if applicable).

8.  Slide the switch on the receiver to REMOTE or ON/OFF switch /

wall switch to ON.

9.  (if applicable) Press ON/OFF button on remote control transmitter 

to "ON."

10. (if applicable) 

Set thermostat on remote control to desired setting.

11.  If the appliance will not operate, follow the instructions "To Turn 

Off Gas To Appliance" and call your service technician or gas 

supplier.

Содержание SLBV 35

Страница 1: ...r other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phon...

Страница 2: ...ting Flame Height 9 Controls for Optional Outside Combustion Air Kit 9 Maintenance Instructions 10 Removing and Installing the Glass Enclosure Panel 11 Installing Volcanic Stone Glowing Embers Rockwoo...

Страница 3: ...ction Informations importantes relatives la s curit page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica para evitar el con...

Страница 4: ...t subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou u...

Страница 5: ...a encendi ndola y apag ndola Limpie bien la placa del interruptor de pared para quitar el polvo y aceite Pegue la etiqueta en la superficie de la placa del interruptor que controla la chimenea Figura...

Страница 6: ...l in these appliances This appliance is only for use with the type of gas indicated on rating plate This appliance is not convertible for use with other gases unless a certified kit is used These appl...

Страница 7: ...ble 4 For elevations above 4500 feet contact your gas supplier or a qualified service technician Deration At higher elevations the amount of BTU fuel value delivered must be reduced by either using ga...

Страница 8: ...gure 1 Gas Controls Control Compartment Access Fireplace gas controls are located in the lower control compartment under the firebox see Figure 1 Remove the control compartment door to access the cont...

Страница 9: ...Valve Hi Lo Flame Control Knob Yellow Ground Wire from DFC Wire Harness Appliance Controls Operation of millivolt and electronic gas control systems differs Before lighting and operating your applianc...

Страница 10: ...fied service techni cian inspection should include ensuring that exhaust or intake passages are unobstructed and vent components are properly assembled and not damaged Homeowner must contact a qualifi...

Страница 11: ...e only when the glass enclosure panel is installed Do NOT remove the glass enclosure panel un less necessary e g to gain access to compo nents within the firebox or to clean the glass Removing the Gla...

Страница 12: ...de CO a colorless odorless toxic gas Separate the Embers rockwool into pieces about the size of a quarter Figure 8 Keep the pieces fluffed up not matted Distribute these pieces over the surface of the...

Страница 13: ...s and the right front log over the right front brackets 2 1 Step 3 1 Right Front Log Nub 2 Position on the left rear log brackets 3 Step 4 Align the hole at the bottom of log 4 over the nub of log 2 a...

Страница 14: ...ogs should be placed in the order shown Position the rear log on the brackets at the rear of the firebox with the log s notches directly over the brackets Proper log and twig placement is critical to...

Страница 15: ...warm yellowish orange flame with an orange body that does not soot the shutter opening must be adjusted between these two extremes Air Shutter Adjustment Guidelines If there is smoke or soot present f...

Страница 16: ...BLY 3 8 Min 9 mm Igniter Rod Pilot Hood Proper Pilot Flame Appearance Figure 14 1 Locateadjustmentrodandadjustairshutter to the standard setting as shown in Figure 13 adjustment rod is located in the...

Страница 17: ...ation If during appliance operation the flame goes out independently of the burner ON OFF switch the safety limit switch may have tripped Some causes for a tripped safety limit switch include the foll...

Страница 18: ...______________________________ Serial Number_________________________________________________________ Date Installed__________________________________________________________ Gas Type Used____________...

Страница 19: ...POWER ADAPTOR HOT NEUTRAL OPTIONAL GROUND BATTERY HOLDER DFC WIRE HARNESS SPARK WIRE CABLE PILOT GROUND WIRE PILOT SENSOR CABLE HOOD IGNITER ROD FLAME SENSOR PILOT TUBE OPTIONAL CPI SWITCH OFF O INTER...

Страница 20: ...temp in F or C Flame icon and low battery indicator Includes batteries Wall clip included Receiver may be wall mounted or placed in the control compartment Includes white face plate Flame icon Low ba...

Страница 21: ...aces Touch Up Paint Kit all models Cat No ModelNo Description 90L73 FTPK B Touch Up Paint Black PA I N T Firebox Liner Kits Cat No ModelNo Description H8083 BLPKB 35TB 35 Buff Traditional H8085 BLPKB...

Страница 22: ...eps 5 through 9 If knob does not pop up when released stop and immediately call your service technician or gas supplier LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE If the pilot will not stay li...

Страница 23: ...le bouton et il sortira subitement La veilleuse devrait rester allum e Si elle s teint r p tez les tapes 5 8 inclusivement Si la manette ne se soul ve pas d elle m me lorsqu on la rel che arr ter et a...

Страница 24: ...ire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and...

Страница 25: ...oir une batterie de secours installer les batteries au besoin 8 Placez l interrupteur du r cepteur en position REMOTE ou l interrupteur mural en position ON 9 Si applicable Appuyez sur le bouton ON OF...

Страница 26: ...m being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform the appropriate appliance checko...

Страница 27: ...witchisusedforburner operation if the standard burner OFF ONswitchisstillinstalledon applianceitmustbeinthe OFF position Optional remote switch kits wall switch timer or remote control A Wallswitchorw...

Страница 28: ...s call a service technician if required C Pilot flame is not engulfing the sensor Call a service technician D Obstructed vent system Call a service technician 4 Soot is present on the glass and panels...

Страница 29: ...H7718 1 7 Orifice Main Burner Natural Gas H1236 1 99K75 1 Orifice Main Burner Propane Gas 62L37 1 19L52 1 8 Bag of Glowing Embers Rockwool 88L53 1 88L53 1 Bag of Decorative Volcanic Stone 80L42 1 80L...

Страница 30: ...eplace code information LENNOX the LENNOX design DAVE LENNOX the image of DAVE LENNOX and other related LENNOXmarksareregisteredorcommonlawtrademarksofLennoxIndustriesInc andareused with permission Pr...

Отзывы: