background image

General Information
900344-00 01/2015

Innovative Hearth Products
Superior

TM 

DRT/DRC6300 Powervent Series Direct-Vent Gas Fireplaces

57

12

/02

/20

13

Printed in U.S.A. © 2013  Innovative Hearth Products LLC

P/N 900223-00, Rev. NC  12/2013

Innovative Hearth Products

1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210

Innovative Hearth Products

Superior™ Brand Gas Fireplaces, Stoves and Inserts

20 Year Limited Warranty

THE WARRANTY

Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior™ Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials 

and workmanship at the time of manufacture. The Product body and firebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against 

thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 20 Year Limited 

Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or replacement 

is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also pay IHP prevail-

ing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to five years. THERE ARE EXCLUSIONS AND LIMITATIONS 

to this 20 Year Limited Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of installation. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following 

the date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This 20 Year Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 

instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.

This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 

provided. The Product body and firebox carry the 20 Year Limited Warranty from the date of installation. Vent components, trim components and paint are excluded from 

this 20 Year Limited Warranty. The following do not carry the 20 Year Limited Warranty but are warranted as follows:

Burner

 – Repair or replacement for one year from the date of installation

Gas components

 – Repair or replacement for one year from the date of installation

Gaskets

 – Repair or replacement for one year from the date of installation

Logs

 – Replacement for one year from the date of installation against thermal breakage only

Optional blowers & remote controls

 – Repair or replacement for one year from the date of installation

Optional glass doors 

– Repair or replacement for 90 days from the date of installation

Tempered glass

 - Replacement for one year from the date of installation

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component

Parts not otherwise listed carry a 90 day warranty from the date of installation.

Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either 

natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures 

and could result in a fire hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; 

(d) damages, repairs or inefficiency resulting from faulty installation or application of the Product.

IHP is not responsible for inadequate fireplace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction condi-

tions which may generate negative pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for drafting conditions caused by 

venting configurations, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions that affect the operation of the unit.

This 20 Year Limited Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction, which are not 

manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to 

any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 

or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.

In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or 

after repair or replacement, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a 

particular use or purpose, and there is no implied condition of fitness for a particular use or purpose.

IHP makes no expressed warranties except as stated in this 20 Year Limited Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.

No one is authorized to change this 20 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 

do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this 20 Year 

Limited Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this 20 Year Limited Warranty and to decide, in its sole discretion, upon the method of settlement.

To receive the benefits and advantages described in this 20 Year Limited Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors.

 IHP shall in no event be responsible for any warranty work done by a 

contractor that is not approved without first obtaining IHP's prior written consent.

 

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/

distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 

IHP Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.SUPERIORFIREPLACES.US.COM.

Содержание Signature DRC6340TYN

Страница 1: ...tique Cet appareil ne peut tre converti d autres gaz sauf si une trousse de conversion est utils e Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any ot...

Страница 2: ...EZ PAS UNE VITRE NON REFROIDIE NE LAISSEZ JAMAIS UN ENFANT DE TOUCHER LA VITRE L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas de contact accidentel avec la vitre chaude...

Страница 3: ...se toca Mantengaalosni osalejadosdela chimeneaenfuncionamiento Supervise enformacercanaalosni osencualquier cuartodondehayaunachimenea funcionandoparaimpedirelcontactocon elvidrio Mantenga la ropa mob...

Страница 4: ...Page 43 Electronic Appliance Inspection Page 44 Ordering Replacement Parts Page 45 Accessory Components Page 46 Lighting Instructions Page 48 Maintenance Schedule Page 50 Troubleshooting Page 51 Repl...

Страница 5: ...TH PRODUCTS POWER VENT DV GAS FIREPLACES DRT6340 45TYN INSTALLATION INSTRUCTIONS WARNING Improper installation adjust ment alteration service or maintenance can cause injury or property damage Refer t...

Страница 6: ...370 m above sea level using the standard burner orifice sizes marked with an in Table 4 For elevations above 4500 ft contact your gas supplier or qualified service technician Deration At higher elevat...

Страница 7: ...ng the location the aesthetic and functional use of the appliance are primary concerns However vent system routing to the exterior and access to the fuel supply are also important Due to high temperat...

Страница 8: ...12 12 4 0 1 22 12 12 to 14 12 5 0 1 52 14 12 to 16 12 6 0 1 83 16 12 to 18 12 7 0 2 13 18 12 to 20 12 7 5 2 29 20 12 to 21 12 8 0 2 44 The vent air intake termination clearances above the high side of...

Страница 9: ...or assembly 36 910 mm within a height of 15 ft above the meter regulator assembly I Clearance to service regulator vent outlet 36 910 mm 36 910 mm J Clearance to nonmechanical air supply inlet to buil...

Страница 10: ...rated 175 F or higher on the underside of the mantel MINIMUM CLEARANCES TO COMBUSTIBLES Appliance And Vent Clearances The appliance is approved with zero clearance to combustible materials on all sid...

Страница 11: ...bed See the page numbers references in the follow ing steps for detailed procedures Step 1 Page 11 Construct the appliance framing Position the appliance within the framing and secure with nailing bra...

Страница 12: ...ow Model No A B C D E F G H J 40 in in 50 5 8 39 1 4 45 25 5 16 34 37 5 8 33 3 32 29 9 32 34 3 4 mm 1286 997 1143 643 864 956 840 744 883 45 in in 56 11 16 44 1 4 47 7 8 28 3 8 40 1 8 43 5 8 38 3 32 3...

Страница 13: ...83 5 8 59 1 8 41 7 8 mm 1286 2124 1502 1064 45 in in 56 3 4 89 7 8 63 1 2 44 7 8 mm 1441 2283 1613 1140 C Back wall of chase enclosure including any finishing materials D A B Figure 9 Corner Framing w...

Страница 14: ...onal Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition or Canada CAN CGA B149 1 latest edition These fireplaces are designed tested and listed for operation and installation only with Secure Vent SV4 5...

Страница 15: ...1 1 1 0 8 4 0 4 1 1 0 0 0 1 1 1 2 9 4 1 4 1 0 1 0 0 1 2 1 5 9 9 4 5 2 6 1 4 0 0 0 1 0 1 1 1 4 0 5 2 4 1 0 0 1 0 1 2 1 5 1 1 5 5 2 6 2 4 0 0 0 0 1 1 1 1 5 0 2 5 5 7 3 3 4 0 2 0 1 1 1 4 1 1 3 5 5 2 4 4...

Страница 16: ...otrequiredasthepipewillsecurely lock when twisted C Attachventcomponentstoeachother Other vent sections may be added to the previously installedsectioninaccordancewiththerequire mentsshowninFigures16a...

Страница 17: ...5HF Secure Vent firestop spacer must be used anytime vent pipe passes through a combustible wall Maintain the horizontal inclined run in a straight slightly elevated plane approximately 1 4 per foot 2...

Страница 18: ...sections in horizontal inclined run as described in Step E Install support straps every three feet 1914 mm along horizontal inclined vent runs using conventional plumber s tape see Figure 16 on Page...

Страница 19: ...m NOTE Centerline of Vent Piping is NOT the Same as the Centerline of the Frame Opening 6 to 48 Vent Section Telescopic vent section Elbow or Appliance Collar Base of Appliance 3 76 mm 1 25 4 mm Adapt...

Страница 20: ...the fireplace to the newly installed junction box near the termination Ensure the cable is safety plated to prevent damage from framing nails and finish drywall screws Route it into the lower control...

Страница 21: ...orten it to fit within the junction box cover WARNING Crimp connectors may be used on stranded cables such as SJOT cable only Solid wire Romex must be connected per the National Electric Code NEC 70 l...

Страница 22: ...this door or replace cracked or broken glass with any materials other than those provided by the appliance manufacturer Theglassdoorofthisappliance must only be replaced as a complete unit as provided...

Страница 23: ...e C When the gas lines are tested and leak free be sure to rinse off the leak testing solution D Re install the access plate making certain the gasket has not been damaged Step 7 INSTALL FIREBOX LINER...

Страница 24: ...and attractive flame pattern Any attempt to use a different log set in the fireplace will void the warranty and will result in incomplete combustion sooting and poor flame quality Logs get very hot a...

Страница 25: ...d Push It Towards The Rear 3 2 4 1 6 5 7 Log Number Description 1 Log Center 2 Log Rear 3 Log Center Left 4 Log Center Right 5 Log Rear Top 6 Log Front Left 7 Log Front Center Table 6 Log Set Align Ho...

Страница 26: ...and seated firmly 2 Positionthedoorframeinfrontofthefirebox openingandengagethebottomflangeover therailatthebottomofthefireboxopening 3 Swing the door up and back Ensure the gasketseatsevenlyasthedoo...

Страница 27: ...finish the installation Leave the ON REMOTE OFF wall switch in the REMOTE position and turn the remote switch OFF Use the remote to adjust the flame height as desired CAUTION Soot will be produced if...

Страница 28: ...WED in the clearance zones around vent compo nents Keep this area free from combustible materials Figure 44 Finished Wall Insulation is NOT ALLOWED in the clearance zones around vent components Keep t...

Страница 29: ...ement parl e dans la r sidence du propri taire En cas de doute collez l tiquette en anglais 2 Rep rezlat l commandeetnettoyez lasoigneuse ment pour liminer la poussi re et les traces degraisseoud huil...

Страница 30: ...lex 6 pieces 91L67 SF GC7 6 Gear Clamp 7 5 190 5 mm for flex 6 pieces Listed Secure Vent Components Cat No Model No Description 77L70 SV4 5L6 6 152mm Vent Section 77L71 SV4 5L12 12 305mm Vent Section...

Страница 31: ...enfants ou les adultes peuvent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour e...

Страница 32: ...contr le le foyer Figure A Choisissez la langue qui est principalement parl e dans la r sidence du propri taire 2 Rep rezlat l commandeetnettoyez lasoigneuse ment pour liminer la poussi re et les trac...

Страница 33: ...area heaters They must not be equipped with wall thermostats or remote controls with thermostat functions CAUTION Hotwhileinoperation Donot touch Severe Burns may result Keep children clothing furnitu...

Страница 34: ...me breadth height and width will diminish 4 for every 1 000 feet of altitude INNOVATIVE HEARTH PRODUCTS POWER VENT DV GAS FIREPLACES DRT6340 45TYN INSTALLATION INSTRUCTIONS Input BTU HR Natural Gas Mo...

Страница 35: ...ldren and others may be susceptible to accidental contact burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to a fireplace or stove install an ad...

Страница 36: ...ction The life span of the receiver batteries depends on various factors Quality of the batteries used Number of ignitions of the appliance etc When the receiver batteries are low no beep willbeemitte...

Страница 37: ...receiver or transmitter are low or depleted the appliance can be turned on manually by sliding the ON REMOTE OFF slider switch to the ON position This will bypass the remote control feature of the sy...

Страница 38: ...lsofoundonapull outpanellocated in the control compartment Always keep the appliance area clear and free from combustible materials gasoline and other flammable liquids Before re lighting the fireplac...

Страница 39: ...the contemporary burner floor kit skip this step and instead refer to the instructions provided with the kit Inspect Wiring Refer to wiring diagram on Page 48 CAUTION Label all wires prior to disconn...

Страница 40: ...gage the nut insert and fasten with two screws to secure the door 4 Installthedoormodestyshieldontopflange glassdoorasfollows grabthedoormodesty shield with both hands with the open hem going down and...

Страница 41: ...not impinge any flames WARNING DO NOT attempt to install the logs until the appliance installation has been completed the gas line connected and tested for leaks and the initial burner operation has b...

Страница 42: ...ter Left 4 Log Center Right 5 Log Rear Top 6 Log Front Left 7 Log Front Center Table 16 Log Set Align Hole At Bottom Of Log 5 Over The Pin On Log 2 6 5 7 2 Figure 61 Placing Logs 5 6 and 7 Engage Log...

Страница 43: ...tion Sooting is caused by incomplete combustionintheflamesandlackofcombustion air entering the air shutter opening To achieve a warm yellow orange flame with an orange body that does not soot the shut...

Страница 44: ...the flame move the adjustment air shutter located on the lower venturi back or forward to increase or reduce the air shutter opening respectively Position the air shut ter to the factory setting as s...

Страница 45: ...e 108 Nashville TN 37210 Visit us at SuperiorFireplaces US com PRODUCT REFERENCE INFORMATION We recommend that you record the important reference information about your fireplace in the space provided...

Страница 46: ...Kits The andiron kits attach to the grate assembly without the use of hardware Firebox Accessories Cat No Model Description 88L53 FGE Bag of Glowing Embers 80L42 FDVS Bag of Volcanic Stone H8312 PGE B...

Страница 47: ...ce Barrier Kits These screen panel kits create a barrier to prevent direct contact with the hot glass The screen panel affixes directly to the front glass enclosure panel Oak Log Set Cat No Model H867...

Страница 48: ...tat on remote control to desired setting 12 If the appliance will not operate follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier OPERATING INSTRUCTIO...

Страница 49: ...on REMOTE 10 Appuyez sur le bouton ON OFF pour s lectionner ON 11 Ajustez le thermostat sur la t l commande l ajustement d sir 12 Si l appareil ne se met pas en marche suivez les instructions intitul...

Страница 50: ...the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform the appropriate applian...

Страница 51: ...ner lights then immediately goes out Gas is not reaching the fireplace Check the gas supply and gas shutoff valves call a service technician if required Loose wires to the valve or ignition module Che...

Страница 52: ...Does the Pilot Flame Cover the Flame Rod Is the Sensor Wire in Good Condition Is There Continuity to Ground from the Pilot Burner No Replace Control Module Does Pressure Switch Open During Operation...

Страница 53: ...e Tubing H2283 1 H2284 1 13 Connector Male H2285 1 H2285 1 14 Orifice Natural Gas H7924 1 H8141 1 15 Bag of Glowing Embers 88L53 1 88L53 1 16 Grate Assembly H4907 1 H4907 1 17 Gas Line Flexible Connec...

Страница 54: ...AMS ILLUSTRATIONS ARE NOT TO SCALE 29 15 21 22 7 17 13 12 6 8 11 9 5 1 4 16 3 20 19 18 31 30 14 REPLACEMENT PARTS INNOVATIVE HEARTH PRODUCTS POWER VENT DV GAS FIREPLACES DRT6340 45TYN INSTALLATION INS...

Страница 55: ...lamp 7 5 190 5 mm for flex 6 pieces INSTALLATION ACCESSORIES Listed Secure Vent Components Cat No Model No Description 77L70 SV4 5L6 6 152mm Vent Section 77L71 SV4 5L12 12 305mm Vent Section 77L72 SV4...

Страница 56: ...General Information 900344 00 01 2015 Innovative Hearth Products SuperiorTM DRT DRC6300 Powervent Series Direct Vent Gas Fireplaces 56 NOTES...

Страница 57: ...e subjected to normal use The Product is designed to burn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will...

Страница 58: ...styles and products Consult your local distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products LLC P N 900344 00 Rev NC 01 2015 1508 Elm Hill Pike Suite 108 Nashvi...

Отзывы: