Superior SDV35-2 Скачать руководство пользователя страница 20

20

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

SUPERIOR

®

  •  DIRECT-VENT GAS FIREPLACES (SDV35-N-2)  •  INSTALLATION INSTRUCTIONS

Figure 35: 

Installing the Square Horizontal Termination (SV4.5HT-2) 

Figure 36: 

Venting Connection and Exterior Wall Recessing of the Horizontal 

Square Termination (SV4.5HT-2)

J.

 

Assemble vent run to exterior wall—

If 

not previously measured, locate the center 

of the vent at the exterior wall. Prepare an 

opening as described in 

Step B

. Assemble 

the vent system to point where the terminus 

of the last section is within 7 in. (178 mm) to 

11 1/4 in. (286 mm) inboard of the exterior 

surface to which the SV4.5 HT termination is 

to be attached, see 

Figure 36

. If the terminus 

of the last section is not within this distance, 

use the 

telescopic vent section SV4.5LA, 

as the last vent section. For wall thicknesses 

greater than that shown in 

Figure 36

, refer 

to Table 9 on Page 21. This table lists the 

additional venting components needed (in 

addition to the termination and adaptor) for a 

particular range of wall thicknesses.

K.

 

Attach termination adaptor—

Attach 

the adaptor (SV4.5RCH, provided with 

the termination) to the vent section or 

telescoping vent section), elbow or appliance 

collar as shown in 

Figure 35

 in the same 

manner as any SV4.5 vent component (refer 

to 

Step E

).

L.

 

Install Firestop/Spacer at exterior wall—

When using the 

square 

termination, install 

SV4.5HF (Secure Vent

®

), SF4.5HF (Secure 

Flex

®

) Firestop/Spacer over the opening at 

the exterior side of the framing, long side up, 

with the 3 inch spacer clearance at the top as 

shown in 

Figure 35

, and nail into place (the 

Firestop/Spacer may also be installed over the 

opening at the interior side of the framing). 

The gap between the vent pipe and a firestop 

can be sealed with noncombustible caulking.

M. Install the desired termination
1. Install the square termination 

(SV4.5HT-2 or SV4.5HTSS)—

For the last 

step , from outside the exterior wall, slide 

the collars of the termination onto the 

adaptor (the outer over the outer and the 

inner inside the inner) until the termination 

seats against the exterior wall surface to 

which it will be attached. Orient the housing 

of the termination with the arrow pointed 

upwards. Secure the termination to the 

exterior wall. 

The horizontal termination 

must not be recessed into the exterior wall 

or siding

 by more than the 1 1/4 in. (32 mm) 

as shown in 

Figure 36

.

SVHRK Snorkel Cap

—The snorkel cap 

is designed to be fitted into a basement 

window box. The SVHRK cap is for use with 

flex vent. The vertical distance between 

the inlet and outlet of the cap is 28 in. 

(711 mm). 

IMPORTANT: The vent termination 

is hot while in operation and for a 

period of time following the use of the 

fireplace. To prevent contact with hot 

surfaces, we recommend the use of a 

Termination Guard

. See

 Page 36.

 This 

can be purchased at your local dealer.

Siding

Stucco

1 1/4 in. Maximum  Recess  of

the  Square  Termination  into

Exterior  Finishing  Material

Exterior Surface of

Framing

6 in. to 9-1/4 in.

(152 to 235 mm)**

Exterior Surface of Siding

Interior Surface of

Finished Wall

Maximum  wall thickness

10 in.(254 mm)**

SV4.5HT-2

Square Termination

Maximum  Extent  of

Vent  Run  Sections

Relative  to  Exterior

Surface  of  Framing

Last Vent Section. Use

T e l e s c o p i c   V e n t

Section (SV4.5LA), If

Necessary

Adaptor

SV4.5RCH

SV4.5HT-2

Square Termination

Venting Connection and Exterior Wall Recessing of the

Horizontal Square Termination (SV4.5HT-2).

*Use silicone caulking to seal

the  top  and  sides  of  the

termination,  up  to  the

underlayment,  stucco,  or

masonry  wall  surface.

**For thicknesses greater

than 10 inches, see Table 8.

*Caulk

*Caulk

SV4.5HT-2

Termination

10-1/2 in.

(267mm)

7 in.

(178)

5-1/8 in.

(130 mm)

12-1/8 in.

(308 mm)

Note: Centerline of Vent Piping is

NOT the Same as the Centerline of

the Framed Opening.

6 to 48 in. Vent Section,

Telescopic vent section,

Elbow or Appliance Collar

See Figure 13 on Page 11

for Min. Distance to Base

of Appliance.

Base of Appliance

3 in.

(76 mm)

1 in.

(25.4 mm)

Adaptor

SV4.5RCH

To help minimize water 

infiltration it is recommended that 

the Firestop/Spacer (SV4.5HF) 

be installed on the exterior 

side of the wall.

Horizontal terminations have been designed to perform in a wide range of weather 

conditions. Our terminations meet or exceed industry standards.
When selecting the locations of your horizontal terminations, do not place the 

termination where water from eaves and adjoining rooflines may create a heavy flow 

of cascading water onto the termination cap. If the cap must be placed where the 

possibility of cascading water exists, it is the responsibility of the builder to direct the 

water away from the termination cap by using gutters or other means.
Take care to carefully follow the installation instructions for the termination, including 

the use of silicone caulking where required.

f i r e - p a r t s . c o m

Содержание SDV35-2

Страница 1: ...xactly a fire or explosion may result causing property damage personal injury or death HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS UNE SURFACE VITR E...

Страница 2: ...paring Appliance Vent Collar 13 Step 4 Installing Vent System 13 Vertical Termination Systems 14 Vent Section Length Chart 14 Vertical Vent Tables and Figures 17 Horizontal Termination System 19 Horiz...

Страница 3: ...sed in the installation of this appliance Seules les trousses de garniture fournies par le fabricant doivent tre utilis es pour l installation de cet appareil This appliance complies with National Saf...

Страница 4: ...OVINCIAL OR TERRITORIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN CGA B149 1 OR CAN CGA B149 2 INSTALLATION CODES REQUIREMENTS FOR THE COMMONWEALTHOFMASSACHUSE...

Страница 5: ...om It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests if floor is above ground level Gas line holes and other openings should be caulked...

Страница 6: ...ion Storm Collar Concentric Vent Pipe Flashing 1 inch 25 4 mm Minimum Clearance to Combustibles Figure 4 Termination Heights for Vents Above Flat or Sloped Roofs Vertical Vent Termination Clearances T...

Страница 7: ...c e m n o n o t e c n a r a e l C J e c n a i l p p a r e h t o y n a o t t e l n i r i a n o i t s u b m o c e h t s e c n a i l p p a r o f m c 5 1 s e h c n i 6 m c 0 3 s e h c n i 2 1 W k 3 h u t...

Страница 8: ...minimize obstructions to the space above the appliance Do not insulate the space between the appliance and the area above it see Figure 7 The minimum height from the base of the appliance to the unde...

Страница 9: ...materials must not be allowed to encroach the area defined by the appliance front face black sheet metal Never allow combustible materials to be positioned in front of or overlapping the appliance fa...

Страница 10: ...EMPT from the 1 2 in clearance to combustible requirements for the firebox outer wrapper Combustible framing may be in direct contact with the nailing flanges and may be located closer than 1 2 in fro...

Страница 11: ...51 Right Side View 14 43 1092 12 7 16 9 16 316 Inches Millimeters 5 29 1 2 749 19 406 35 1 8 892 37 5 32 944 Overall unit height Note J box can be relocated in either the right front or left front cor...

Страница 12: ...ition Canada Step 2 ROUTING GAS LINE Route a 1 2 in 13 mm gas line to the left side of the appliance as shown in Figure 14 Gas lines must be routed constructed and made of materials that are in strict...

Страница 13: ...USA or the current standards of CAN CGA B149 1 in Canada Ensure clearances are in accordance with local installation codes and the requirements of the gas supplier D gagement conforme aux codes d inst...

Страница 14: ...1 0 1 0 5 0 6 6 8 1 5 5 1 0 0 0 0 4 4 5 0 9 1 5 7 8 5 1 1 0 0 0 4 5 5 6 9 1 5 7 3 6 1 0 1 0 0 4 5 5 5 0 2 5 2 1 7 1 0 1 1 5 0 7 7 0 2 5 2 7 1 0 0 0 6 0 6 5 1 1 2 5 2 6 7 1 1 0 0 6 0 7 5 7 1 2 5 2 1 8...

Страница 15: ...h 3 pilot holes Slip the plain end over the locking channel end of a standard SV4 5 vent component the required distance and secure with three screws Maintain a minimum 1 in 25 mm clearance to combust...

Страница 16: ...he required clearances to combustibles 1 in 25 mm at all sides for all vertical runs and 3 in 76 mm at the top 1 in 25 mm at sides and 1 in 25 mm at the bottom for all horizontal inclined runs H Frame...

Страница 17: ...Spacer SF4 5VF Ceiling Firestop Spacer SV4 5VF Figure 30 Rear Vent ONE 90 DEGREE ELBOW This table shows a 1 V to 2 H ratio For every 1 foot of V vertical you are allowed 2 feet of H horizontal run up...

Страница 18: ...feet 6 096 m Max V V1 H H1 40 ft 12 192 m Max meters meters Example If 20 feet of H horizontal vent run is needed then 4 feet minimum of V vertical vent will be required This table shows a 1 V to 5 H...

Страница 19: ...outer pipe elements with the same procedure Sealant and securing screws are not required Note An elbow may also be attached to the appliance collar Attach in the same manner as you would a vent secti...

Страница 20: ...ll or siding by more than the 1 1 4 in 32 mm as shown in Figure 36 SVHRK Snorkel Cap The snorkel cap is designed to be fitted into a basement window box The SVHRK cap is for use with flex vent The ver...

Страница 21: ...ing SV4 5HT 2 termination kit HORIZONTAL VENT FIGURES TABLES Note Two 45 degree elbows may be used in place of one 90 degree elbow The same rise to run ratios as shown in the venting figures for 90 el...

Страница 22: ...then 4 feet minimum of V vertical vent will be required This table shows a 1 V to 5 H ratio For every 1 foot of V vertical you are allowed 5 feet of H horizontal run up to a maximum horizontal run of...

Страница 23: ...5 1 524 Elbow Only 5 1 524 1 0 305 10 3 048 2 0 610 15 4 572 3 0 914 20 6 096 4 1 219 meters TABLE L meters H Maximum 1 1 H H1 20 feet 6 096 m Max V V H H 40 ft 12 192 m Max Example If 20 feet of H h...

Страница 24: ...inner adaptor collar approximately 1 2 inch from the end 3 Pull and extend the inner flexible vent pipe 4 Slide the inner flex pipe over the adaptor collar Ensure the flexible vent pipe completely eng...

Страница 25: ...The gas valve is set in place and pre wired at the factory on both models Wiring see Figure 46 This unit is not provided with factory installed controls therefore one of the optional control switches...

Страница 26: ...oor by sliding the hinge pin located at the door s left side to the right until it disengages from the left corner post hole Pull the door diagonally to the left away from the fireplace The control va...

Страница 27: ...e pipes fittings can result in corrosion over time A Light the appliance refer to the lighting instructions label in the control compartment or in the Care and Operation Instructions manual B Brush al...

Страница 28: ...e logs until the appliance installa tion has been completed the gas lineconnectedandtestedforleaks and the initial burner operation has been checked out Thesizeandpositionofthelogset was engineered to...

Страница 29: ...wn Position the rear log on the brackets at the rear of the firebox with the log s notches directly over the brackets Position the right log log no 3 by inserting the pin from the rear log into the ho...

Страница 30: ...is provided to aid you in achieving the correct air shutter adjustment for your installation Figure 54 Door Removal Removing the Glass Enclosure Panel see Figure 54 Remove the top radiant panel To acc...

Страница 31: ...gures 65 and 66 All models must have hoods installed prior to operating Slide the hood into the slots on the lower edge of the radiant panel Figure 57 FINISHING REQUIREMENTS Wall Details Complete fini...

Страница 32: ...raisse ou d huile Collez l tiquette sur la surface de la plaque de l interrupteur mural qui contr le le foyer Figure A ou du thermostat mural Figure B Choisissez la langue qui est principalement parl...

Страница 33: ...246 SV4 5HF 10 Firestop Spacer Hori zontal rigid 3 1 1 spac ing 10 Pack H2247 SV4 5VF 10 Firestop Spacer Verti cal rigid 1 1 1 spac ing 10 Pack 96K92 SV4 5SP Support Plate INSTALLATION ACCESSORIES Lis...

Страница 34: ...Small Square Termination for flex without flex vent Ref Instr 750204M INSTALLATION ACCESSORIES CONTINUED All compressed flex vents can be expanded up to two times Listed Secure Flex Components Cat Mod...

Страница 35: ...the appliance see Page 30 WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes andrequirementsofthea...

Страница 36: ...crews as shown in Figure 59 Tighten the screws to 25 in lb Step 8 Install the enclosed identification label to the valve body where it can be easily seen Step 9 Refer to Figure 60 and replace the pilo...