NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

SUPERIOR

®

  •  DIRECT-VENT GAS FIREPLACES (SDV35-N-2)  •  INSTALLATION INSTRUCTIONS

Note:  Trim Thimble/ 

Extension To Desired Length 

And Pitch At The Roof Line 

14 in. Min.

Pitched Roof 

Pitched Roof 

Bow Roof 

14 in. Min.

Outer Pipe Of 

Chimney 

Outer Pipe Of 

Chimney 

Outer Pipe Of 

Chimney 

14 in. Min.

Firestop 

Thimble 

Extension 

13 in.

Firestop 

Thimble 

Firestop 

Thimble 

Thimble 

SV-FSTFE 

Figure 22: Roof Penetration

Min. 10-1/2"

(267 mm)

Min. 10-1/2"

     (267 mm)

Figure 20: Frame Ceiling Opening

Route the vent sections through the framed 

opening and secure the firestop/spacer with 

8d nails or other appropriate fasteners at 

each corner. 

Remember to maintain 1 in. (25 mm) 

clearance to combustibles, framing 

members, and attic or ceiling insulation 

when running vertical chimney sections. 

Attic insulation shield (96K94) may be used 

to obtain the required clearances indicated 

here. See installation accessories table on 

Pages 33 and 34

. The gap between the vent 

pipe and a vertical firestop can be sealed 

with non-combustible caulking.
D2. Install firestop thimble at the ceiling to 

roof location—

Position appropriate firestop 

thimble  at the bottom side of ceiling and secure  

temporarily with two appropriate fasteners. 

Attach permanently, using at least two more 

fasteners, after vent sections have been as-

sembled through the firestop thimble and after 

any necessary adjustments have been made.
Ensure the thimble penetrates the roof opening. 

The thimble must extend completely through the 

ceiling or roof cavity to the outermost plane of 

the roof. Use thimble extension SVTE26 when 

the distance between the outside of the roof and 

the inside of the ceiling exceeds the height of the 

firestop thimble. The thimble provides for zero 

clearances to combustibles and must be used 

at the ceiling/roof in manufactured homes with 

Secure Vent

 double wall vent sections. Maintain 

1 in. (25.4 mm) clearance between the thimble 

and the outer pipe of the secure vent chimney 

system. See 

Figure 22

 for pitched roofs or flat 

roofs with flat ceilings or 

Figure 23

 for pitched 

roofs with cathedral ceilings. 

Vertical (Offset) Installation

Analyze the vent routing and determine the 

quantities of vent sections and number of 

elbows required. Refer to 

Vertical Vent 

Figures and Tables on 

Page 14

 to select 

the type of vertical installation desired. 

Vent sections are available in net lengths of 

4 1/2 in. (114 mm), 10 1/2 in. (267 mm), 

22 1/2 in. (572 mm), 34 1/2 in. (876 mm) 

and 46 1/2 in. (1181 mm). Refer to the 

Vent 

Section Length Chart on 

Page 14

 for an aid 

in selecting length combinations. Elbows are 

available in 90° and 45° configurations. Refer 

to 

Figure 25

 

for the SV4.5E45 and SV4.5E90 

elbow dimensional specifications. 
Where required, a 

telescopic vent section 

(SV4.5LA)

 may be used to provide the 

installer with an option in installing in tight 

and confined spaces or where the vent run 

made up of fixed length pieces develops a 

joint in a undesirable location, or will not 

build up to the required length. The SV4.5LA 

Telescopic Vent Section has an effective 

length of from 1 1/2 in. (38 mm) to 7 1/2 in. 

(191 mm). The SV4.5LA is fitted with a 

locking inclined channel end (identical to a 

normal vent section component) and a plain 

end with 3 pilot holes. Slip the plain end over 

the locking channel end of a standard SV4.5 

vent component the required distance and 

secure with three screws.

Maintain a minimum 1 in. (25 mm) 

clearance to combustible materials for 

all vertical elements. Clearances for all 

horizontal elements are 3 in. (76 mm) 

on top, 1 in. (25 mm) on sides and 1 in. 

(25 mm) on the bottom.
A.

 

Frame ceiling opening—

Use a plumb line 

from the ceiling above the appliance to locate 

center of the vertical run. Cut and/or frame 

an opening, 10 1/2 in. x 10 1/2 in. (267 mm 

x 267 mm) inside dimensions, about this 

center mark (

Figure 20

).

B.

 

Attach vent components to appliance—

Secure Vent

®

 SV4.5 direct vent system 

components are unitized concentric pipe 

components featuring positive twist lock 

connections (see 

Figure 21

). All of the 

appliances covered in this document are 

fitted with collars having locking inclined 

channels. 

The dimpled end of the vent components fit over 

the appliance collar to create the positive twist 

lock connection.To attach a vent component to 

the appliance collar, align the dimpled end over 

the collar, adjusting the radial alignment until the 

four locking dimples are aligned with the inlet of 

the four inclined channels on the collar (refer to 

Figure 21

). Push the vent component against 

the collar until it fully engages, then twist the 

component clockwise, running the dimples down 

and along the incline channels until they seat at 

the end of the channels. The unitized design of the 

Secure Vent

®

 components will engage and seal 

both the inner and outer pipe without the need for 

sealant or screws. If desired a #6 x 1/2 in. screw 

may be used at the joint, but it is not required as 

the pipe will securely lock when twisted. 
Note: An elbow may also be attached to the 

appliance collar. Attach in the same manner 

as you would a vent section. 

C. Attach vent components to each other—

Other vent sections may be added to the 

previously installed section in accordance 

with the requirements of the vertical vent 

figures and tables. To add another vent 

component to a length of vent run, align the 

dimpled end over the inclined channel end 

of the previously installed section, adjusting 

the radial alignment until the four locking 

dimples are aligned with the inlets of the four 

incline channels of the previous section. 
Push the vent component against the 

previous section until it fully engages, then 

twist the component clockwise running the 

dimples down and along the incline channels 

until they seat at the end of the channels.

This seating position is indicated by the 

alignment of the arrow and dimple as 

shown in

 

Figure 21.

D1.

 

Install firestop/spacer at ceiling—

When using Secure Vent, use SV4.5VF 

firestop/spacer at ceiling joists; when using 

Secure Flex

®

, use SF4.5VF firestop/spacer. If 

there is living space above the ceiling level, 

the firestop/spacer must be installed on the 

bottom side of the ceiling. If attic space is 

above the ceiling, the firestop/spacer must be 

installed on the top side of the joist. 

Figure 21: Connecting Vent 

Components

Arrow

Arrow

Align the dimple (four places) of 

the upper vent section with the 

opening of the locking incline 

channel on the lower vent sec-

tion or appliance collar. Twist 

vent component clockwise to 

engage and seal until arrow and 

dimple align.

Dimple

Locking 

Incline 

Channel

Connected Vent 

Sections

Appliance Collar or 

Vent Section

f i r e - p a r t s . c o m

Содержание SDV35-2

Страница 1: ...xactly a fire or explosion may result causing property damage personal injury or death HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS UNE SURFACE VITR E...

Страница 2: ...paring Appliance Vent Collar 13 Step 4 Installing Vent System 13 Vertical Termination Systems 14 Vent Section Length Chart 14 Vertical Vent Tables and Figures 17 Horizontal Termination System 19 Horiz...

Страница 3: ...sed in the installation of this appliance Seules les trousses de garniture fournies par le fabricant doivent tre utilis es pour l installation de cet appareil This appliance complies with National Saf...

Страница 4: ...OVINCIAL OR TERRITORIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN CGA B149 1 OR CAN CGA B149 2 INSTALLATION CODES REQUIREMENTS FOR THE COMMONWEALTHOFMASSACHUSE...

Страница 5: ...om It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests if floor is above ground level Gas line holes and other openings should be caulked...

Страница 6: ...ion Storm Collar Concentric Vent Pipe Flashing 1 inch 25 4 mm Minimum Clearance to Combustibles Figure 4 Termination Heights for Vents Above Flat or Sloped Roofs Vertical Vent Termination Clearances T...

Страница 7: ...c e m n o n o t e c n a r a e l C J e c n a i l p p a r e h t o y n a o t t e l n i r i a n o i t s u b m o c e h t s e c n a i l p p a r o f m c 5 1 s e h c n i 6 m c 0 3 s e h c n i 2 1 W k 3 h u t...

Страница 8: ...minimize obstructions to the space above the appliance Do not insulate the space between the appliance and the area above it see Figure 7 The minimum height from the base of the appliance to the unde...

Страница 9: ...materials must not be allowed to encroach the area defined by the appliance front face black sheet metal Never allow combustible materials to be positioned in front of or overlapping the appliance fa...

Страница 10: ...EMPT from the 1 2 in clearance to combustible requirements for the firebox outer wrapper Combustible framing may be in direct contact with the nailing flanges and may be located closer than 1 2 in fro...

Страница 11: ...51 Right Side View 14 43 1092 12 7 16 9 16 316 Inches Millimeters 5 29 1 2 749 19 406 35 1 8 892 37 5 32 944 Overall unit height Note J box can be relocated in either the right front or left front cor...

Страница 12: ...ition Canada Step 2 ROUTING GAS LINE Route a 1 2 in 13 mm gas line to the left side of the appliance as shown in Figure 14 Gas lines must be routed constructed and made of materials that are in strict...

Страница 13: ...USA or the current standards of CAN CGA B149 1 in Canada Ensure clearances are in accordance with local installation codes and the requirements of the gas supplier D gagement conforme aux codes d inst...

Страница 14: ...1 0 1 0 5 0 6 6 8 1 5 5 1 0 0 0 0 4 4 5 0 9 1 5 7 8 5 1 1 0 0 0 4 5 5 6 9 1 5 7 3 6 1 0 1 0 0 4 5 5 5 0 2 5 2 1 7 1 0 1 1 5 0 7 7 0 2 5 2 7 1 0 0 0 6 0 6 5 1 1 2 5 2 6 7 1 1 0 0 6 0 7 5 7 1 2 5 2 1 8...

Страница 15: ...h 3 pilot holes Slip the plain end over the locking channel end of a standard SV4 5 vent component the required distance and secure with three screws Maintain a minimum 1 in 25 mm clearance to combust...

Страница 16: ...he required clearances to combustibles 1 in 25 mm at all sides for all vertical runs and 3 in 76 mm at the top 1 in 25 mm at sides and 1 in 25 mm at the bottom for all horizontal inclined runs H Frame...

Страница 17: ...Spacer SF4 5VF Ceiling Firestop Spacer SV4 5VF Figure 30 Rear Vent ONE 90 DEGREE ELBOW This table shows a 1 V to 2 H ratio For every 1 foot of V vertical you are allowed 2 feet of H horizontal run up...

Страница 18: ...feet 6 096 m Max V V1 H H1 40 ft 12 192 m Max meters meters Example If 20 feet of H horizontal vent run is needed then 4 feet minimum of V vertical vent will be required This table shows a 1 V to 5 H...

Страница 19: ...outer pipe elements with the same procedure Sealant and securing screws are not required Note An elbow may also be attached to the appliance collar Attach in the same manner as you would a vent secti...

Страница 20: ...ll or siding by more than the 1 1 4 in 32 mm as shown in Figure 36 SVHRK Snorkel Cap The snorkel cap is designed to be fitted into a basement window box The SVHRK cap is for use with flex vent The ver...

Страница 21: ...ing SV4 5HT 2 termination kit HORIZONTAL VENT FIGURES TABLES Note Two 45 degree elbows may be used in place of one 90 degree elbow The same rise to run ratios as shown in the venting figures for 90 el...

Страница 22: ...then 4 feet minimum of V vertical vent will be required This table shows a 1 V to 5 H ratio For every 1 foot of V vertical you are allowed 5 feet of H horizontal run up to a maximum horizontal run of...

Страница 23: ...5 1 524 Elbow Only 5 1 524 1 0 305 10 3 048 2 0 610 15 4 572 3 0 914 20 6 096 4 1 219 meters TABLE L meters H Maximum 1 1 H H1 20 feet 6 096 m Max V V H H 40 ft 12 192 m Max Example If 20 feet of H h...

Страница 24: ...inner adaptor collar approximately 1 2 inch from the end 3 Pull and extend the inner flexible vent pipe 4 Slide the inner flex pipe over the adaptor collar Ensure the flexible vent pipe completely eng...

Страница 25: ...The gas valve is set in place and pre wired at the factory on both models Wiring see Figure 46 This unit is not provided with factory installed controls therefore one of the optional control switches...

Страница 26: ...oor by sliding the hinge pin located at the door s left side to the right until it disengages from the left corner post hole Pull the door diagonally to the left away from the fireplace The control va...

Страница 27: ...e pipes fittings can result in corrosion over time A Light the appliance refer to the lighting instructions label in the control compartment or in the Care and Operation Instructions manual B Brush al...

Страница 28: ...e logs until the appliance installa tion has been completed the gas lineconnectedandtestedforleaks and the initial burner operation has been checked out Thesizeandpositionofthelogset was engineered to...

Страница 29: ...wn Position the rear log on the brackets at the rear of the firebox with the log s notches directly over the brackets Position the right log log no 3 by inserting the pin from the rear log into the ho...

Страница 30: ...is provided to aid you in achieving the correct air shutter adjustment for your installation Figure 54 Door Removal Removing the Glass Enclosure Panel see Figure 54 Remove the top radiant panel To acc...

Страница 31: ...gures 65 and 66 All models must have hoods installed prior to operating Slide the hood into the slots on the lower edge of the radiant panel Figure 57 FINISHING REQUIREMENTS Wall Details Complete fini...

Страница 32: ...raisse ou d huile Collez l tiquette sur la surface de la plaque de l interrupteur mural qui contr le le foyer Figure A ou du thermostat mural Figure B Choisissez la langue qui est principalement parl...

Страница 33: ...246 SV4 5HF 10 Firestop Spacer Hori zontal rigid 3 1 1 spac ing 10 Pack H2247 SV4 5VF 10 Firestop Spacer Verti cal rigid 1 1 1 spac ing 10 Pack 96K92 SV4 5SP Support Plate INSTALLATION ACCESSORIES Lis...

Страница 34: ...Small Square Termination for flex without flex vent Ref Instr 750204M INSTALLATION ACCESSORIES CONTINUED All compressed flex vents can be expanded up to two times Listed Secure Flex Components Cat Mod...

Страница 35: ...the appliance see Page 30 WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes andrequirementsofthea...

Страница 36: ...crews as shown in Figure 59 Tighten the screws to 25 in lb Step 8 Install the enclosed identification label to the valve body where it can be easily seen Step 9 Refer to Figure 60 and replace the pilo...

Отзывы: