background image

2

REPLACEMENT PARTS LIST

MISC. COMPONENTS

Item Cat.No Description

Qty.

Where Used

1a

98K95

Hood, Black - 2 in.

1

SSDVPF

1b

97K52

Hood, Black - 0 in.

2

All Models

2a

H337

Upper Louver Panel, Black  

- 2 in.

1

SSDVPF

2b

H3377

Upper Louver Panel, Black 

- 0 in.

2

All Models

3a

H3725

Glass Enclosure Assembly 

- 2 in.

1

SSDVPF

3b

H372

Glass Enclosure Assembly 

- 0 in.

2

All Models

a

H338

Lower Louver Panel, Black 

- 2 in.

1

SSDVPF

b

H3380

* Lower Louver Panel, Black 

- 0 in.

2

All Models

5

56L93

Nameplate Logo (Brand)

2

All Models

6

69L62

Log Set 

1

All Models

7

88L53

Bag of Glowing Gas Embers 

1

All Models

8

80L2

Bag of Decorative Volcanic 

Stone

2

All Models

10a

H865

Main Burner Set, Rear

1

All Models

10b

H866

Main Burner Set, Front

1

All Models

11

19L51

Gasket, Burner Tray Mounting

1

All Models

12

3K85

Gasket, Venturi Tube Mounting 

(per burner)

1

All Models

13a

7L92

Venturi Tube / Air Shutter, 

Rear

1

All Models

13b

60L0

Venturi Tube / Air Shutter, 

Front

1

All Models

1

69L21

Latch, Glass Enclosure Panel

(ST) & 

6 (PF)

All Models

16

H897

Burner Adjustment Rod

1

All Models

17

93L32

Flex Gas Line Connector, FFGC

1

All Models

* Superior Nameplate Logo, 56L93, is sold separately.

(MV) MILLIVOLT - GAS COMPONENTS

Item Cat.No Description

Qty.

Where Used

30

H6209

Gas Valve - SIT, Natural Gas

1

SSDVST-NM

30

88J53

Gas Valve - SIT, Propane

1

SSDVST-PM

31

10K86

Piezo Igniter

1

SSDVST-NM 

& SSDVST-PM

32

69L17

Pilot Assembly, Natural Gas

1

SSDVST-NM

32

69L18

Pilot Assembly, Propane

1

SSDVST-PM

33

60J79

Pilot Generator

1

SSDVST-NM 

& SSDVST-PM

3

7L57

Thermocouple

1

SSDVST-NM 

& SSDVST-PM

35

7L56

Pilot Tube

1

SSDVST-NM 

& SSDVST-PM

36

7L58

Electrode And Cable

1

SSDVST-NM 

& SSDVST-PM

37

60J80

Orifice, Burner, Natural Gas, # 

(.086”) 

2

All NG Models

37

19L52

Orifice, Propane, #55 (.052”)

2

All LP Models

       WARNING 

Failure to position the parts in accordance with these 

diagrams  or  failure  to  use  only  parts  specifically 

approved with this appliance may result in property 

damage or personal injury.

       AVERTISSEMENT 

Risque de dommages ou de blessures si les pièces 

ne sont pas installées conformément à ces schémas 

et ou si des pièces autres que celles spécifiquement 

approuvées avec cet appareil sont utilisées.

Contact an Authorized LHP dealer to obtain any of these parts. Never 

use substitute materials. Use of non-approved parts can result in poor 

performance and safety hazards.

(E) ELECTRONIC - GAS COMPONENTS

0

62L18

Gas Valve - Honeywell, Electronic, 

Natural Gas

1

SSDVST-NE

0

62L19

Gas Valve - Honeywell, Electronic, 

Propane

1

SSDVST-PE

1

62L1

Pilot Assembly, Electronic, Natural 

Gas

1

SSDVST-NE

1

62L15

Pilot Assembly, Electronic, 

Propane

1

SSDVST-PE

2

2J32

Transformer, Electronic

1

SSDVST-NE 

(& PE)

3

87L5

Igniter Assembly (Kit)

1

SSDVST-NE 

(& PE)

5

H867

Pilot Tube, Electronic

1

SSDVST-NE 

(& PE)

37

60J80

Orifice, Burner, Natural Gas, # 

(.086”) 

2

All NG Models

37

19L52

Orifice, Propane, #55 (.052”)

2

All LP Models

Содержание Millivolt SSDVPF-CNM-B

Страница 1: ...phones se trouvant dans le b timent o vous trouvez Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournis seur Si vous ne pouvez rejoindre le fournisseur d...

Страница 2: ...e Embers and Logs Page 9 Burner Flame Appearance Sooting Page 11 Burner Air Shutter Adjustments Page 12 Millivolt Appliance Checkout Page 12 Electronic Appliance Checkout Page 12 Warranty Page 13 Prod...

Страница 3: ...ion is hot while in operation and for a period of time fol lowing the use of the fireplace Young children should be carefully supervised when they are in the same area as a hot termination To prevent...

Страница 4: ...e Sizes Sea Level to High Altitude All Models These appliances are tested and approved for installation at elevations of 0 4500 feet 0 1372 meters above sea level using the standard burnerorificesizes...

Страница 5: ...er may be turned ON and OFF using a wall switch remote control optionalonunitrockerswitch FRS or wall thermostat To operate Toggle the switch between its ON and OFF positions If your millivolt applian...

Страница 6: ...located on the front of the valve refer to Figure 3 H I LO W H T P T H T P T P I L O T P I L O T O N i t OFF IN OUT Manifold Pressure Tap Inlet Pressure Tap Pilot Adjustment Screw HI LO Variable Flame...

Страница 7: ...para controlar la chimenea encuentre el transmisor y l mpielo bien para quitar el polvo y aceite Pegue la etiqueta en la superficie del transmisor Figura C Seleccione el idioma que m s se habla en la...

Страница 8: ...ch heating season depending on the circumstances present The following cleaning solutions are approved for use to clean glass Non ammonia based household cleaner 50 50 mix of white vinegar and water G...

Страница 9: ...he control compartment To disengage the two latches from the bottom vee flange of the glass enclosure panel reach for the handles located towards the back of the latches and pull the handles down towa...

Страница 10: ...he top of the pile of decorative volcanic stone Place a few quar ter sized pieces of the glowing ember material on the pan burner in front of the burned out area on both sides of the log set The glowi...

Страница 11: ...urfaces adjacent to the vent termination Sooting is caused by incomplete combustion in the flames and lack of combustion air entering the air shutter opening To achieve a warm yellowish orange flame w...

Страница 12: ...k or sooty adjust theairshutter incrementally toamore open position until the proper flame appearance is achieved If flame stays lowered blue adjust the air shutter incrementally to a more closed posi...

Страница 13: ...s Wiringdiagramsareprovidedhereforreference purposesonly Thisinformationisalsoprovided onschematicsattacheddirectlytotheappliance on a pullout panel located within the control compartment CAUTION Labe...

Страница 14: ...tes briefly to verify that a signal has been sent The Model RCL is designed to operate with all mil livolt ignition systems as well as electronic ignition systems It may be installed with use for eith...

Страница 15: ...glass enclosure panel resulting in the appearance of a picture frame ref Form 750 098M 4 Piece Door Trim Kits Polished Brass Brushed Stainless Where Used Cat Model Cat Model 26M83 4DFK40PB 26M86 4DFK...

Страница 16: ...e with these appliances Order kits as part of the periodic maintenance of the appliance Decorative Firebox Accessories all models Cat No ModelNo Description 88L53 FGE Bag of Glowing Embers 1 oz rockwo...

Страница 17: ...ot touch any electric switch do not use any phone in your building TO TURN OFF GAS TO APPLIANCE 1 Turn remote wall switch OFF The pilot will remain lit for normal service 2 For complete shutdown turn...

Страница 18: ...rer appelez un technicien qualifi Quiconque tente de forcer la manette ou de la r parer peut provoquer une explosion ou un incendie D N utilisez pas cet appareil s il a t plong dans l eau m me partiel...

Страница 19: ...Electronic 1 For complete shut down turn remote wall switch to OFF 2 Open lower control compartment door 3 Turn the OFF ON switch to OFF Do not force 4 Close the main line shut off valve 5 Close lowe...

Страница 20: ...que ON qui alimente l appareil interrupteur mural ou l appareil 9 Fermez la porte du compartiment de contr le du bas 10 Si l appareil ne fonctionne pas suivre les instructions intitul es Pour fermer l...

Страница 21: ...s of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform the appropriate ap...

Страница 22: ...ch if burner comeson replacedefectivewallswitch Ifokay jumper wiresacrosswallswitchwiresatvalve ifburnercomes on wires are faulty or connections are bad B Thermopile may not be generating suf ficient...

Страница 23: ...24V common leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identifyproperlead thischeckmust be done with the valve control con nected and igniter powered NO Check...

Страница 24: ...0K86 Piezo Igniter 1 SSDVST NM SSDVST PM 32 69L17 Pilot Assembly Natural Gas 1 SSDVST NM 32 69L18 Pilot Assembly Propane 1 SSDVST PM 33 60J79 Pilot Generator 1 SSDVST NM SSDVST PM 34 74L57 Thermocoupl...

Страница 25: ...USTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS DIAGRAMS Firebox Cabinet 1a 2a 3a a 8 10a 10b 37 13a 31 30 13b 16 12 12 7 17 1 1b 3b b 5 2b 11 32 33 3 36 35 0 30 3 1 5 2 6 Note Cabinet and Firebox shown...

Страница 26: ...26 NOTES...

Страница 27: ...27 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE NOTES...

Страница 28: ...rves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code...

Отзывы: