5.2.3 Power check
Question:
The equipment doesn’t work correctly at the power set up?
Answer:
• Ensure that the
INTERLOCK
light turns off. It indicates that no external interlock
signal inhibites the delivering power from exciter.
• Ensure that the
ASI Input
is performed by 75 Ohm cables with SMA
connectors.
• Check current
RF
output setting and enable output (if not
already enabled) following menu path
SET
⇒
Power
⇒
( xxx )
.
Output power can also be set in a Pwr OFF condition; in this condition, (Fwd) output
power reading on the display will be 0 (zero), that will be delivered the moment
you switch back to Pwr ON state.
• Check output power level and set to the desired level from the
Power
Menu,
which you can call up by pressing these keys in the order:
SET
⇒
Power
⇒
Power:
xxx %
.
Set the desired ampli
er output power, whereas the forward power value shown
on the display (
Power: xxx %
) gives actual output power reading.