Printed in U.S.A. © 2013  Innovative Hearth Products LLC

P/N 900223-00, Rev. NC  12/2013

Innovative Hearth Products

1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210

Innovative Hearth Products

Superior™ Brand Gas Fireplaces, Stoves and Inserts

20 Year Limited Warranty

THE WARRANTY

Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior™ Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials 

and workmanship at the time of manufacture. The Product body and firebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against 

thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 20 Year Limited 

Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or replacement 

is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also pay IHP prevail-

ing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to five years. THERE ARE EXCLUSIONS AND LIMITATIONS 

to this 20 Year Limited Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of installation. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following 

the date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This 20 Year Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 

instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.

This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 

provided. The Product body and firebox carry the 20 Year Limited Warranty from the date of installation. Vent components, trim components and paint are excluded from 

this 20 Year Limited Warranty. The following do not carry the 20 Year Limited Warranty but are warranted as follows:

Burner

 – Repair or replacement for one year from the date of installation

Gas components

 – Repair or replacement for one year from the date of installation

Gaskets

 – Repair or replacement for one year from the date of installation

Logs

 – Replacement for one year from the date of installation against thermal breakage only

Optional blowers & remote controls

 – Repair or replacement for one year from the date of installation

Optional glass doors 

– Repair or replacement for 90 days from the date of installation

Tempered glass

 - Replacement for one year from the date of installation

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component

Parts not otherwise listed carry a 90 day warranty from the date of installation.

Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either 

natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures 

and could result in a fire hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; 

(d) damages, repairs or inefficiency resulting from faulty installation or application of the Product.

IHP is not responsible for inadequate fireplace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction condi-

tions which may generate negative pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for drafting conditions caused by 

venting configurations, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions that affect the operation of the unit.

This 20 Year Limited Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction, which are not 

manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to 

any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 

or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.

In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or 

after repair or replacement, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a 

particular use or purpose, and there is no implied condition of fitness for a particular use or purpose.

IHP makes no expressed warranties except as stated in this 20 Year Limited Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.

No one is authorized to change this 20 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 

do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this 20 Year 

Limited Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this 20 Year Limited Warranty and to decide, in its sole discretion, upon the method of settlement.

To receive the benefits and advantages described in this 20 Year Limited Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors.

 IHP shall in no event be responsible for any warranty work done by a 

contractor that is not approved without first obtaining IHP's prior written consent.

 

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/

distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 

IHP Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.SUPERIORFIREPLACES.US.COM.

Содержание DRT40CL40DEN

Страница 1: ...urnisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installationetl entretiendoivent treassur spar un installateur ou un service d entretien qualifi ou par l...

Страница 2: ...DE TOUCHER LA VITRE EL VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de...

Страница 3: ...uede causar quemaduras graves si se toca Mantenga a los ni os alejados de la chimenea en funcionamiento Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando p...

Страница 4: ...ic stone and one bag of vermiculate is located in the bottom compartment 5 oneventrestrictortobeappliedasshownon page14 restrictoristapedtotheenvelope 6 barriers 7 front face assemblies NOTE If the ba...

Страница 5: ...e absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition or the Natural Gas and Propane Instal lation Code CSA B149 1 The appliance when installed must be electri ca...

Страница 6: ...Vent Requirements IntheCommonwealthofMassachusetts hori zontal terminations installed less than seven 7 feet above the finished grade must comply with the following additional requirements A hard wir...

Страница 7: ...ir tightness and caulk firestops MANUFACTURED HOME REQUIREMENTS Thisappliancemaybeinstalledinanaftermarket permanently located manufactured home and must be installed in accordance with the manu factu...

Страница 8: ...ada Vertical Vent Termination Clearances Terminatemultipleventterminationsaccordingto the installation codes listed above and Figures 4 and 5 Note See Figure 42 on Page 22 for the exterior wall recess...

Страница 9: ...m 5 127 mm minimum G Clearance to inside corner 6 152 mm minimum 6 152 mm minimum H Clearance to each inside of center line extended above meter regulator assembly 36 910 mm within a height of 15 ft a...

Страница 10: ...ible materials such as surrounds and other appliance trim may be installed on the appliance face with these exceptions they must not cover any portion of the removable glass panel or control compartme...

Страница 11: ...Bottom SERVICE CLEARANCES Feet meters Front Back Sides 3 feet 0 9 meters Table 5 Figure 10 Unit Parts Identification Detailed Installation Steps The appliance is shipped with all gas controls and com...

Страница 12: ...s and or rear of the unit using the factory providednailingflanges Installthenailing flanges 8 DRT40ST 4 DRT40PF DRT40CL and DRT40CR as shown in Figure 12 using the existing screws Position the firepl...

Страница 13: ...drywall For 1 2 drywall use 23 Provide Additional Space For Side Vent Seal Cap If Installing Against A Solid Wall LibraPF Peninsula Gas Line Center of gas line is 3 in 76 mm up from floor 41 1 2 1054...

Страница 14: ...1 4 1200 37 3 4 959 40 3 16 1021 41 1041 37 940 34 1 8 867 23 7 16 595 27 3 4 705 23 7 8 607 41 1041 2 51 FRAMING SPACERS Top and both sides FINISHED WALL BRACKET Front and back edge of unit top Step...

Страница 15: ...ner Right 10 5 16 262 12 303 3 76 6 7 8 174 41 1041 34 1 8 867 1 26 25 9 16 649 23 7 8 607 21 3 8 543 37 11 16 957 45 7 16 1154 11 3 8 289 10 254 21 3 8 543 TOP VIEW FRAMING SPACERS Top and both sides...

Страница 16: ...hutoff valve See Step 7 on Page 30 Installingagassupplylinefromthefuelsupplyto theapplianceinvolvesnumerousconsiderations of materials protection sizing locations con trols pressure sediment andmore C...

Страница 17: ...wall such as a chase There is no requirement for inspection openings in the enclosing wall at any of the joints in the vent pipe Installation of Vent Restrictor A vent restrictor may be needed with th...

Страница 18: ...5 2 1 9 1 0 0 1 6 0 7 5 2 3 2 5 7 3 9 1 0 0 0 0 5 5 7 3 2 5 7 9 1 1 0 0 0 5 6 5 1 4 2 5 2 1 0 2 0 0 0 7 0 7 6 4 2 5 0 2 1 0 0 7 0 8 2 5 2 1 2 0 1 0 7 0 8 4 6 2 2 2 0 0 1 7 0 8 6 7 2 3 2 0 0 0 8 0 8 9...

Страница 19: ...the Effective Vent Length Chart Table 7 on page 18 for an aid in selecting length combinations Elbows are available in 90 and 45 configura tions Refer to Figure 30 for the SV4 5E45 and SV4 5E90 elbow...

Страница 20: ...e vent outlet One method of support is by utiliz ing field provided support straps conventional plumber s tape Secure the plumber s tape to theframingmemberswithnailsorscrews Loop the tape around the...

Страница 21: ...Top Vent STRAIGHT Figure 37 Top Vent TWO 90 DEGREE ELBOWS 40 feet 12 2 meters Maximum uCeiling Firestop Spacer SV4 5VF uWhenusingSecureFlex use Firestop Spacer SF4 5VF uCeiling Firestop Spacer SV4 5V...

Страница 22: ...using Secure Flex use Firestop Spacer SF4 5VF vWhen using Secure Flex use Firestop Spacer SF4 5HF uCeiling Firestop Spacer SV4 5VF uCeiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF Table...

Страница 23: ...a joint does not occurintheceilingorroofjoists Allowforelbows as indicated in Figure 30 on page 18 Maintain a minimum 1 25 mm clearance to combustiblesontheverticalsections Clearances for the horizont...

Страница 24: ...adaptor for a particular range of wall thicknesses L Install Firestop Spacer at exterior wall When using the square termination install SV4 5HF Secure Vent SF4 5HF Secure Flex Firestop Spacer over the...

Страница 25: ...anytime vent pipe passes through a combustible floor or ceiling SV4 5HF Secure Vent SF4 5HF Secure Flex firestop spacer must be used anytime vent pipe passes through a combustible wall Note Secure Ven...

Страница 26: ...ical vent will be required Thistableshowsa1 V to5 H ratio Forevery1 foot of V vertical you are allowed 5 feet of H H1 horizontal run up to a maximum horizontal run of 20 feet Table H H H1 Maximum V Mi...

Страница 27: ...ft 12 192 m Max V H H1 V1 v Wall Firestop Spacer SV4 5HF uCeiling Firestop Spacer SV4 5VF uCeiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF vWall Firestop Spacer SV4 5HF Figure 47 Side Ve...

Страница 28: ...dofMill PacBlack 700 F high temperature sealant Catalog No 10K81 to the inner adaptor collar approximately 1 2 inch from the end 3 Pull and extend the inner flexible vent pipe 4 Slide the inner flex p...

Страница 29: ...0VAC power supply 2 Install the junction box and receptacle outlet to the left of the valve in the front for optional blower kit See junction box and receptacle outlet as explained in steps 1 11 for B...

Страница 30: ...d in the gas piping within the home to prevent moisture and debris in the line from damaging the valve These appliances are equipped with a gas flex lineforuse wherepermitted inconnectingthe unit to t...

Страница 31: ...sly the left and right top corners of the door The door is hinged at the bottom Removethebottomcompartmentdoor by sliding the hinge pin located at the door s left side to the right until it disengages...

Страница 32: ...Replace logs if removed for pilot inspection To light the burner turn ON the remote wall switch and rotate the gas valve control knob counterclockwise to the ON position ON will be at the top side of...

Страница 33: ...BURNER Note This appliance is provided with enough Glowing Embers for several applications do not use all that is in a new bag at one time For best glowingeffect replacetheembermaterialannually Replac...

Страница 34: ...he Grate And Slide It Forward Against The Grate Here Position Log 2 Over The Grate Bar And Slide It Against The Back Of The Grate Here Position Groove At The Bottom Of Log 2 Over The Grate Here And Sl...

Страница 35: ...ire log set 55M04 2 6 5 4 1 3 Figure 62 3 Grate Assembly 5 Position Small End Of Log 6 On The Notch Of Log 3 Here 6 4 Position The Round End Of Log 6 Against The Notch Of Log 4 Here Two Charred Spots...

Страница 36: ...the top flange of thedoorframeoverthetopofthefireboxframe Let the bottom of the door frame swing gently intowardsthefireplaceensuringthatthegasket seats evenly as the door frame draws shut Fasten the...

Страница 37: ...ly to ensure that the proper flame appearance has been achieved If the following conditions are present adjust accordingly If flame appears weak or sooty adjust the air shutter incrementally to a more...

Страница 38: ...Figure 65 Air Shutter Adjusting Rod Orifice Increase Shutter Opening In This Direction Decrease Shutter Opening In This Direction Note Burners are omitted in this view for clarity MAIN BURNER FACTORY...

Страница 39: ...z que l interrupteur contr le le fonctionnement du foyer en le faisant basculerdeMarche Arr t etvice versa Nettoyez soigneusement la plaque murale de l interrupteur ou le thermostat mural pour liminer...

Страница 40: ...lashings come packaged with a storm collar 77L78 SV4 5F Flat Roof Flashing 77L79 SV4 5FA 1 12 to 7 12 Adjustable Flashing 77L80 SV4 5FB 7 12 to 12 12 Adjustable Flashing 77L81 SV4 5SC6 Storm Collar 6...

Страница 41: ...Cat Model Description 17M52 SV4 5HGS 1 Termination Guard Square 1 pack Ref instr 750 109M 17M53 SV4 5HGS 12 Termination Guard Hori zontal Square 12 pack Ref instr 750 109M 87L02 SV4 5HGS Termination G...

Страница 42: ...nel by the tab on the panel s right end pull the right end of the panel away from the cabinet and then pull the panel diagonally out of the left side cabinet panel slots In the above procedure reverse...

Страница 43: ...models Figure 72 illustrates the orifice Always check and verify correct orifice size B Install the burner as shown in Figure 73 When reinstalling the igniter assembly use extreme care to prevent dam...

Страница 44: ...il ni proximit WARNING Children and adults should be alerted to the hazards of high surfacetemperatureandshould stay away to avoid burns or clothing ignition CARE AND OPERATIONS WARNINGS Burn in Perio...

Страница 45: ...euvent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer...

Страница 46: ...burning pilot flame Exercise caution when using products with combustible vapors H I LO W TPTH TP TH P I L O T P I L O T O N i t OFF Variable Flame Height Adjustment Manifold Pressure Port Inlet Press...

Страница 47: ...nea verifiquequeelinterruptor opera la chimenea encendi ndola y apag ndola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterr...

Страница 48: ...tion should include ensuring that exhaust or intake passages are unobstructed and vent components are properly assembled and not damaged Homeowner must contact a qualified service technician at once i...

Страница 49: ...front glass enclosure panel should not be re moved except to gain access to the components within the firebox Removing Glass Enclosure Panels see Figure 76 To access the glass door securing latches fi...

Страница 50: ...is provided with enough Glowing Embers for several applications do not use all that is in a new bag at one time For best glowingeffect replacetheembermaterialannually ReplacementGlowing Embers are ava...

Страница 51: ...he Grate And Slide It Forward Against The Grate Here Position Log 2 Over The Grate Bar And Slide It Against The Back Of The Grate Here Position Groove At The Bottom Of Log 2 Over The Grate Here And Sl...

Страница 52: ...ire log set 55M04 2 6 5 4 1 3 Figure 80 3 Grate Assembly 5 Position Small End Of Log 6 On The Notch Of Log 3 Here 6 4 Position The Round End Of Log 6 Against The Notch Of Log 4 Here Two Charred Spots...

Страница 53: ...ot soot the shutter opening must be adjusted between these two extremes Air Shutter Adjustment Guidelines Amount of Primary Air Flame Color Air Shutter Adjustment If air shutter is closed too far Flam...

Страница 54: ...ance is achieved If flame remains blue adjust the air shutter incrementally to a more closed position until the proper flame appearance is achieved 4 Leave the control knob off pilot on in the ON posi...

Страница 55: ...he appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions concerning the install...

Страница 56: ...n Timer Includes batteries Child lock Low battery indicator Receiver may be wall mounted or placed in the valve compartment Cost Effective Solution Simple On Off operation Workswithmillivoltandlowvolt...

Страница 57: ...of the fireplace burner Install the OFF ON wallswitchinaconvenientlocationnearthefireplace WhiteWallSwitchKit Cat No ModelNo Description 85L87 FWSK OFF ONWallSwitchKit Accessory Components CONTINUED...

Страница 58: ...gs excessive condensation can be caused by long lateral runs too many elbows and or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure...

Страница 59: ...released stop and immediately call your service technician or gas supplier LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE If the pilot will not stay lit after several tries turn the gas control kn...

Страница 60: ...arr ter et appeler imm diatement un technicien qualifi ou le fournisseur de gaz Si la veilleuse ne reste pas allum e apr s plusieurs tentatives r glez la manette d admission du gaz la position OFF et...

Страница 61: ...appliance 10 If applicable Set thermostat to desired setting Turn wall on off switch unit mounted on off switch or remote control switch ON 11 Close control compartment OPERATING INSTRUCTIONS 1 If ap...

Страница 62: ...applicable R glez le thermostat la temp rature la plus basse Tournez e c n a t s i d e l r t n o c e l u o t i n u l r u s r u e t p u r r e t n i l e l a r u m r u e t p u r r e t n i l OFF 2 Coupez...

Страница 63: ...lve system troubleshooting should only be accomplished by a qualified service technician Clean and or adjust pilot flame for maximum flame impinge ment on thermocouple Figure 11 on page 14 Check burne...

Страница 64: ...Voltage Transformer Limit Controller Thermostat Wiring 2 CHECK START NO Plug Control Harness Into Valve Wait For Internal Check Delay YES Igniter Warms Up And Glows Red With Pilot Burner Cable Connec...

Страница 65: ...Assembly 55M42 1 1 1 1 9 Gasket Venturi Tube Mounting 43K85 1 1 1 1 10 Venturi Tube Arm 42M80 1 1 1 1 11 Switch Rocker 80L41 1 1 1 1 12 Air Shutter Adjustment Rod H3707 1 1 1 1 13 Flexline Gas Conduc...

Страница 66: ...LACEMENT PARTS LIST continued GAS CONTROLS HONEYWELL Electronic GAS CONTROLS SIT Millivolt No DESCRIPTION Natural Propane Part No Qty Part No Qty 30 Gas Valve SIT H6209 1 88J53 1 31 Piezo Igniter 10K8...

Страница 67: ...ural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c d...

Страница 68: ...ial number Date fireplace was Installed Type of gas fireplace uses Dealer name Innovative Hearth Products reserves the right to make changes at any time with out notice in design materials specificati...