background image

46

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Installation and Operation Instructions

900299-00, 08/2015

Innovative Hearth Products
DRT40 Multi View Series Direct Vent Gas Fireplace

Figure 75

Honeywell Electronic

 Gas Valve

Figure 74

Note: The piezo igniter is located on the modesty panel - refer to Figure 1.

Variable Flame Height Adjustment 

( Millivolt Appliances only) 

1.

 All Millivolt appliances are equipped with 

a variable gas control valve. Flame height for 

these models may be adjusted through a range 

between fixed low and high settings, alternately, 

while the appliance is in operation. 

Adjust the flame height as desired after lighting 

the appliance by rotating the variable adjustment 

control knob located on the front of the valve 

(refer to Figure 74)

.

 

(An extension is provided 

to this knob so that the adjustment may be made 

at the modesty panel.)

2.

 When lit for the first time, this appliance will 

emit a slight odor for an hour or two. This is due 

to the “burn-in” of internal paints and lubricants 

used in the manufacturing process.

3. 

Keep lower control compartment clean by 

vacuuming or brushing at least twice a year. 

More frequent cleaning may be required due to 

excessive lint from carpeting, bedding materials, 

etc. It is important that control compartments, 

burners and circulating air passageways of the 

appliance be kept clean and clear of obstruction 

of venting and combustion air.

4.

 Always turn off gas to the pilot (millivolt 

appliances) before cleaning. Before re-lighting, 

refer to the lighting instructions in this manual. 

Instructions are also found on a pull-out panel 

located on the floor of the appliance.

5.

 Always keep the appliance area clear and 

free from combustible materials, gasoline and 

other flammable liquids.

6.

 Remember, Millivolt appliances have a con-

tinuous burning pilot flame. Exercise caution 

when using products with combustible vapors.

HI

LO W

TPTH

TP

TH

PILO

T

PIL

OT

ON

i

t

OFF

Variable Flame Height Adjustment

Manifold Pressure Port

Inlet Pressure Port

Main Gas

Control Knob

IN

OUT

SIT Millivolt Gas Valve

ON/OFF Switch

Electronic

Gas Control

Valve

Inlet

Pressure

Port

Manifold Pressure Port

OFF

IN

P

S

I

ON

CONTROL

IG

N

IT

ER

Millivolt Appliances -

To light millivolt appliances refer to the detailed 

lighting instructions found on 

page  59 

(English)

 

and page 60

 

(French)

.  

Millivolt appliance 

lighting instructions may also be found on the 

pull out lighting instruction labels attached to 

the gas control valve

.

Millivolt appliances are fitted with an ON/OFF 

Rocker Switch for appliance ON/OFF control.  

Refer to 

Figure 1

 for its location. Once the 

pilot is lighted, the ON/OFF rocker switch will 

control the appliance ON/OFF operation.  To 

operate:  Toggle the switch between its ON and 

OFF positions.

If your millivolt appliance is equipped with an 

optional remote wall switch or remote control 

kit and the pilot is lit, the appliance main burner 

may be turned on and off with the wall switch 

or remote control.  

Electronic Appliances -

To light electronic appliances refer to the 

detailed lighting instructions found in both 

English and French on

 pages 61 and 62

 of 

these instructions respectively.  

Electronic 

appliance lighting instructions may also be 

found on the pull out lighting instruction labels 

attached to the gas control valve

.  Electronic 

appliances are fitted with an ON/OFF Rocker 

Switch for appliance ON/OFF control.  Refer to 

Figure 73

 for its location. 

Once the pilot is lighted, the ON/OFF rocker 

switch will control the appliance ON/OFF opera-

tion. To operate:  Toggle the switch between its 

ON and OFF positions.

If your electronic appliance is equipped with an 

optional remote wall switch or remote control 

kit the appliance main burner may be turned on 

and off with the wall switch or remote control.

Содержание DRT40CL40DEN

Страница 1: ...urnisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installationetl entretiendoivent treassur spar un installateur ou un service d entretien qualifi ou par l...

Страница 2: ...DE TOUCHER LA VITRE EL VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de...

Страница 3: ...uede causar quemaduras graves si se toca Mantenga a los ni os alejados de la chimenea en funcionamiento Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando p...

Страница 4: ...ic stone and one bag of vermiculate is located in the bottom compartment 5 oneventrestrictortobeappliedasshownon page14 restrictoristapedtotheenvelope 6 barriers 7 front face assemblies NOTE If the ba...

Страница 5: ...e absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition or the Natural Gas and Propane Instal lation Code CSA B149 1 The appliance when installed must be electri ca...

Страница 6: ...Vent Requirements IntheCommonwealthofMassachusetts hori zontal terminations installed less than seven 7 feet above the finished grade must comply with the following additional requirements A hard wir...

Страница 7: ...ir tightness and caulk firestops MANUFACTURED HOME REQUIREMENTS Thisappliancemaybeinstalledinanaftermarket permanently located manufactured home and must be installed in accordance with the manu factu...

Страница 8: ...ada Vertical Vent Termination Clearances Terminatemultipleventterminationsaccordingto the installation codes listed above and Figures 4 and 5 Note See Figure 42 on Page 22 for the exterior wall recess...

Страница 9: ...m 5 127 mm minimum G Clearance to inside corner 6 152 mm minimum 6 152 mm minimum H Clearance to each inside of center line extended above meter regulator assembly 36 910 mm within a height of 15 ft a...

Страница 10: ...ible materials such as surrounds and other appliance trim may be installed on the appliance face with these exceptions they must not cover any portion of the removable glass panel or control compartme...

Страница 11: ...Bottom SERVICE CLEARANCES Feet meters Front Back Sides 3 feet 0 9 meters Table 5 Figure 10 Unit Parts Identification Detailed Installation Steps The appliance is shipped with all gas controls and com...

Страница 12: ...s and or rear of the unit using the factory providednailingflanges Installthenailing flanges 8 DRT40ST 4 DRT40PF DRT40CL and DRT40CR as shown in Figure 12 using the existing screws Position the firepl...

Страница 13: ...drywall For 1 2 drywall use 23 Provide Additional Space For Side Vent Seal Cap If Installing Against A Solid Wall LibraPF Peninsula Gas Line Center of gas line is 3 in 76 mm up from floor 41 1 2 1054...

Страница 14: ...1 4 1200 37 3 4 959 40 3 16 1021 41 1041 37 940 34 1 8 867 23 7 16 595 27 3 4 705 23 7 8 607 41 1041 2 51 FRAMING SPACERS Top and both sides FINISHED WALL BRACKET Front and back edge of unit top Step...

Страница 15: ...ner Right 10 5 16 262 12 303 3 76 6 7 8 174 41 1041 34 1 8 867 1 26 25 9 16 649 23 7 8 607 21 3 8 543 37 11 16 957 45 7 16 1154 11 3 8 289 10 254 21 3 8 543 TOP VIEW FRAMING SPACERS Top and both sides...

Страница 16: ...hutoff valve See Step 7 on Page 30 Installingagassupplylinefromthefuelsupplyto theapplianceinvolvesnumerousconsiderations of materials protection sizing locations con trols pressure sediment andmore C...

Страница 17: ...wall such as a chase There is no requirement for inspection openings in the enclosing wall at any of the joints in the vent pipe Installation of Vent Restrictor A vent restrictor may be needed with th...

Страница 18: ...5 2 1 9 1 0 0 1 6 0 7 5 2 3 2 5 7 3 9 1 0 0 0 0 5 5 7 3 2 5 7 9 1 1 0 0 0 5 6 5 1 4 2 5 2 1 0 2 0 0 0 7 0 7 6 4 2 5 0 2 1 0 0 7 0 8 2 5 2 1 2 0 1 0 7 0 8 4 6 2 2 2 0 0 1 7 0 8 6 7 2 3 2 0 0 0 8 0 8 9...

Страница 19: ...the Effective Vent Length Chart Table 7 on page 18 for an aid in selecting length combinations Elbows are available in 90 and 45 configura tions Refer to Figure 30 for the SV4 5E45 and SV4 5E90 elbow...

Страница 20: ...e vent outlet One method of support is by utiliz ing field provided support straps conventional plumber s tape Secure the plumber s tape to theframingmemberswithnailsorscrews Loop the tape around the...

Страница 21: ...Top Vent STRAIGHT Figure 37 Top Vent TWO 90 DEGREE ELBOWS 40 feet 12 2 meters Maximum uCeiling Firestop Spacer SV4 5VF uWhenusingSecureFlex use Firestop Spacer SF4 5VF uCeiling Firestop Spacer SV4 5V...

Страница 22: ...using Secure Flex use Firestop Spacer SF4 5VF vWhen using Secure Flex use Firestop Spacer SF4 5HF uCeiling Firestop Spacer SV4 5VF uCeiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF Table...

Страница 23: ...a joint does not occurintheceilingorroofjoists Allowforelbows as indicated in Figure 30 on page 18 Maintain a minimum 1 25 mm clearance to combustiblesontheverticalsections Clearances for the horizont...

Страница 24: ...adaptor for a particular range of wall thicknesses L Install Firestop Spacer at exterior wall When using the square termination install SV4 5HF Secure Vent SF4 5HF Secure Flex Firestop Spacer over the...

Страница 25: ...anytime vent pipe passes through a combustible floor or ceiling SV4 5HF Secure Vent SF4 5HF Secure Flex firestop spacer must be used anytime vent pipe passes through a combustible wall Note Secure Ven...

Страница 26: ...ical vent will be required Thistableshowsa1 V to5 H ratio Forevery1 foot of V vertical you are allowed 5 feet of H H1 horizontal run up to a maximum horizontal run of 20 feet Table H H H1 Maximum V Mi...

Страница 27: ...ft 12 192 m Max V H H1 V1 v Wall Firestop Spacer SV4 5HF uCeiling Firestop Spacer SV4 5VF uCeiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF vWall Firestop Spacer SV4 5HF Figure 47 Side Ve...

Страница 28: ...dofMill PacBlack 700 F high temperature sealant Catalog No 10K81 to the inner adaptor collar approximately 1 2 inch from the end 3 Pull and extend the inner flexible vent pipe 4 Slide the inner flex p...

Страница 29: ...0VAC power supply 2 Install the junction box and receptacle outlet to the left of the valve in the front for optional blower kit See junction box and receptacle outlet as explained in steps 1 11 for B...

Страница 30: ...d in the gas piping within the home to prevent moisture and debris in the line from damaging the valve These appliances are equipped with a gas flex lineforuse wherepermitted inconnectingthe unit to t...

Страница 31: ...sly the left and right top corners of the door The door is hinged at the bottom Removethebottomcompartmentdoor by sliding the hinge pin located at the door s left side to the right until it disengages...

Страница 32: ...Replace logs if removed for pilot inspection To light the burner turn ON the remote wall switch and rotate the gas valve control knob counterclockwise to the ON position ON will be at the top side of...

Страница 33: ...BURNER Note This appliance is provided with enough Glowing Embers for several applications do not use all that is in a new bag at one time For best glowingeffect replacetheembermaterialannually Replac...

Страница 34: ...he Grate And Slide It Forward Against The Grate Here Position Log 2 Over The Grate Bar And Slide It Against The Back Of The Grate Here Position Groove At The Bottom Of Log 2 Over The Grate Here And Sl...

Страница 35: ...ire log set 55M04 2 6 5 4 1 3 Figure 62 3 Grate Assembly 5 Position Small End Of Log 6 On The Notch Of Log 3 Here 6 4 Position The Round End Of Log 6 Against The Notch Of Log 4 Here Two Charred Spots...

Страница 36: ...the top flange of thedoorframeoverthetopofthefireboxframe Let the bottom of the door frame swing gently intowardsthefireplaceensuringthatthegasket seats evenly as the door frame draws shut Fasten the...

Страница 37: ...ly to ensure that the proper flame appearance has been achieved If the following conditions are present adjust accordingly If flame appears weak or sooty adjust the air shutter incrementally to a more...

Страница 38: ...Figure 65 Air Shutter Adjusting Rod Orifice Increase Shutter Opening In This Direction Decrease Shutter Opening In This Direction Note Burners are omitted in this view for clarity MAIN BURNER FACTORY...

Страница 39: ...z que l interrupteur contr le le fonctionnement du foyer en le faisant basculerdeMarche Arr t etvice versa Nettoyez soigneusement la plaque murale de l interrupteur ou le thermostat mural pour liminer...

Страница 40: ...lashings come packaged with a storm collar 77L78 SV4 5F Flat Roof Flashing 77L79 SV4 5FA 1 12 to 7 12 Adjustable Flashing 77L80 SV4 5FB 7 12 to 12 12 Adjustable Flashing 77L81 SV4 5SC6 Storm Collar 6...

Страница 41: ...Cat Model Description 17M52 SV4 5HGS 1 Termination Guard Square 1 pack Ref instr 750 109M 17M53 SV4 5HGS 12 Termination Guard Hori zontal Square 12 pack Ref instr 750 109M 87L02 SV4 5HGS Termination G...

Страница 42: ...nel by the tab on the panel s right end pull the right end of the panel away from the cabinet and then pull the panel diagonally out of the left side cabinet panel slots In the above procedure reverse...

Страница 43: ...models Figure 72 illustrates the orifice Always check and verify correct orifice size B Install the burner as shown in Figure 73 When reinstalling the igniter assembly use extreme care to prevent dam...

Страница 44: ...il ni proximit WARNING Children and adults should be alerted to the hazards of high surfacetemperatureandshould stay away to avoid burns or clothing ignition CARE AND OPERATIONS WARNINGS Burn in Perio...

Страница 45: ...euvent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer...

Страница 46: ...burning pilot flame Exercise caution when using products with combustible vapors H I LO W TPTH TP TH P I L O T P I L O T O N i t OFF Variable Flame Height Adjustment Manifold Pressure Port Inlet Press...

Страница 47: ...nea verifiquequeelinterruptor opera la chimenea encendi ndola y apag ndola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterr...

Страница 48: ...tion should include ensuring that exhaust or intake passages are unobstructed and vent components are properly assembled and not damaged Homeowner must contact a qualified service technician at once i...

Страница 49: ...front glass enclosure panel should not be re moved except to gain access to the components within the firebox Removing Glass Enclosure Panels see Figure 76 To access the glass door securing latches fi...

Страница 50: ...is provided with enough Glowing Embers for several applications do not use all that is in a new bag at one time For best glowingeffect replacetheembermaterialannually ReplacementGlowing Embers are ava...

Страница 51: ...he Grate And Slide It Forward Against The Grate Here Position Log 2 Over The Grate Bar And Slide It Against The Back Of The Grate Here Position Groove At The Bottom Of Log 2 Over The Grate Here And Sl...

Страница 52: ...ire log set 55M04 2 6 5 4 1 3 Figure 80 3 Grate Assembly 5 Position Small End Of Log 6 On The Notch Of Log 3 Here 6 4 Position The Round End Of Log 6 Against The Notch Of Log 4 Here Two Charred Spots...

Страница 53: ...ot soot the shutter opening must be adjusted between these two extremes Air Shutter Adjustment Guidelines Amount of Primary Air Flame Color Air Shutter Adjustment If air shutter is closed too far Flam...

Страница 54: ...ance is achieved If flame remains blue adjust the air shutter incrementally to a more closed position until the proper flame appearance is achieved 4 Leave the control knob off pilot on in the ON posi...

Страница 55: ...he appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions concerning the install...

Страница 56: ...n Timer Includes batteries Child lock Low battery indicator Receiver may be wall mounted or placed in the valve compartment Cost Effective Solution Simple On Off operation Workswithmillivoltandlowvolt...

Страница 57: ...of the fireplace burner Install the OFF ON wallswitchinaconvenientlocationnearthefireplace WhiteWallSwitchKit Cat No ModelNo Description 85L87 FWSK OFF ONWallSwitchKit Accessory Components CONTINUED...

Страница 58: ...gs excessive condensation can be caused by long lateral runs too many elbows and or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure...

Страница 59: ...released stop and immediately call your service technician or gas supplier LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE If the pilot will not stay lit after several tries turn the gas control kn...

Страница 60: ...arr ter et appeler imm diatement un technicien qualifi ou le fournisseur de gaz Si la veilleuse ne reste pas allum e apr s plusieurs tentatives r glez la manette d admission du gaz la position OFF et...

Страница 61: ...appliance 10 If applicable Set thermostat to desired setting Turn wall on off switch unit mounted on off switch or remote control switch ON 11 Close control compartment OPERATING INSTRUCTIONS 1 If ap...

Страница 62: ...applicable R glez le thermostat la temp rature la plus basse Tournez e c n a t s i d e l r t n o c e l u o t i n u l r u s r u e t p u r r e t n i l e l a r u m r u e t p u r r e t n i l OFF 2 Coupez...

Страница 63: ...lve system troubleshooting should only be accomplished by a qualified service technician Clean and or adjust pilot flame for maximum flame impinge ment on thermocouple Figure 11 on page 14 Check burne...

Страница 64: ...Voltage Transformer Limit Controller Thermostat Wiring 2 CHECK START NO Plug Control Harness Into Valve Wait For Internal Check Delay YES Igniter Warms Up And Glows Red With Pilot Burner Cable Connec...

Страница 65: ...Assembly 55M42 1 1 1 1 9 Gasket Venturi Tube Mounting 43K85 1 1 1 1 10 Venturi Tube Arm 42M80 1 1 1 1 11 Switch Rocker 80L41 1 1 1 1 12 Air Shutter Adjustment Rod H3707 1 1 1 1 13 Flexline Gas Conduc...

Страница 66: ...LACEMENT PARTS LIST continued GAS CONTROLS HONEYWELL Electronic GAS CONTROLS SIT Millivolt No DESCRIPTION Natural Propane Part No Qty Part No Qty 30 Gas Valve SIT H6209 1 88J53 1 31 Piezo Igniter 10K8...

Страница 67: ...ural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c d...

Страница 68: ...ial number Date fireplace was Installed Type of gas fireplace uses Dealer name Innovative Hearth Products reserves the right to make changes at any time with out notice in design materials specificati...

Отзывы: