Superior DRT3033 Скачать руководство пользователя страница 37

Installation 

900285-00 11/2014

Innovative Hearth Products
Superior

TM 

DRT3000 Series Direct-Vent Gas Fireplaces

37

2. 

Wire the control switch within the millivolt control circuit using the 15 ft of 2-conductor wire supplied with 

the unit (

Figure 33

).

NOTE: 

The supplied 15 ft of 2-conductor wire has one end of each conductor connected to the gas valve circuit and 

the other end of each conductor placed loose inside the bottom compartment.

 CAUTION 

In millivolt systems, do NOT connect a wall switch to a 120 V power supply.

Figure 31: Wiring Diagram—Electronic Gas Valves

B   = BLACK

BR = BROWN

GY = GRAY

PU = PURPLE

R   = RED

BL  = BLUE

G  = GREEN

O  = ORANGE

W  = WHITE

Y   = YELLOW

WIRING COLOR CODE

ELECTRONIC PILOT ASSEMBLY

 

HOOD

PROFLAME VALVE

PROFLAME

DFC BOARD

 

SPLIT

FLOW

BATTERY

HOLDER

BATTERY

HOLDER

ON/OFF WALL

SWITCH

HI/LOW

SWITCH

IGNITER ROD

CPI SWITCH

OFF (O) = INTERMITTANT PILOT MODE

ON   (–) = STANDING PILOT MODE

DFS WIRE HARNESS

PILOT GROUND WIRE

SPARK WIRE CABLE

PILOT TUBE

FLAME SENSOR

PILOT

SENSOR

CABLE

AC/DC 

POWER

ADAPTOR

JUNCTION  BOX

120V  AC

HOT

NEUTRAL

GROUND

B

BL

2B 1B

2A

2

1

1A

R

O

B

1

2

G

W

BL

BL

O

O

R

R

G

W

B

B
W

G

R

W

B

Y
G
O

G

W

R

BL

B

BL

W

G

G

Y

O

Y

B

B

B

R

B

Electronic Wiring

One of the following optional controls must be used:

• 

ON/OFF Wall Switch,

• 

Thermostat, or

• 

Remote Control.

See the 

Operation

 section on 

Page 50

 for more details.

NOTE: 

Electronic models must be connected to the main power supply.

1. 

Route a 3-wire, 120 Vac, 60 Hz, 1 ph power supply to the fireplace junction box.

2. 

Remove the electrical inlet cover plate from the side of the unit by removing the plate’s securing screws 

(

Table 8

).

3. 

If unit is not supplied with a strain relief, remove the cover plate knockout. Then, feed the power supply wire 

through the knockout opening and into the unit junction box.

4. 

Connect the black power supply wire to the lower outlet’s red pigtail lead (

Figure 32

 and 

Figure 33

). Connect the 

white power supply wire to the outlet’s common terminal.

Содержание DRT3033

Страница 1: ...c le type de gaz indiqué sure la plaque signalétique Cet appareil ne peut être converti à d autres gaz sauf si une trousse de conversion est utilsée Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Le...

Страница 2: ...ISQUE DE BRÛLURES NE TOUCHEZ PAS UNE VITRE NON REFROIDIE NE LAISSEZ JAMAIS UN ENFANT DE TOUCHER LA VITRE L écran pare étincelles fourni avec ce foyer réduit le risque de brûlure en cas de contact accidentel avec la vitre chaude et doit être installé pour la protection Des enfants et Des personnes à risques PELIGRO EL VIDRIO CALIENTE CAUSARÁ QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS ...

Страница 3: ...aves si se toca Mantengaalosniñosalejadosde lachimeneaenfuncionamiento Superviseenformacercanaalos niñosencualquiercuartodondehaya unachimeneafuncionandopara impedirelcontactoconelvidrio Mantenga la ropa mobiliario gasolina y otros líquidos inflamables alejados de la chimenea Aún después de haber apagado el gas las superficies de la chimenea permanecen extremadamente calientes Asegúrese de colocar...

Страница 4: ...ng 8 Introduction 8 Installation Requirements for the Commonwealth of Massachusetts 10 Cold Climate Insulation 10 Manufactured Home Requirements 11 Location 11 Vent Termination Clearances 12 Minimum Clearances to Combustibles 14 Wall Finishes Surrounds Mantels 15 Installation Preparation 15 Installation Sequence 16 Construct the Fireplace Framing 16 Route the Gas Supply Line to the Fireplace 18 In...

Страница 5: ...te to keep toddlers young children and other at risk individuals out of the room and away from hot surfaces Les jeunes enfants devraient être surveillés étroitement lorsqu ils se trouvent dans la même pièce que l appareil Les tout petits les jeunes enfants ou les adultes peuvent subir des brûlures s ils viennent en contact avec la surface chaude Il est recommandé d installer une barrière physique ...

Страница 6: ...o this manual For assistance or additional information consult a qualified installer service agency or the gas supplier AVERTISSEMENT Une installation un réglage une modification une réparation ou un entretien mal effectué peut causer des dommages matériels ou des blessures Voir la notice de l utilisateur qui accompagne l appareil Pour de l aide ou des renseignements supplémentaires consultez un i...

Страница 7: ...OTE If the barrier becomes damaged the barrier shall be replaced with the manufacturer s barrier for this appliance For use with barrier s Part No s F1902 33 Models F1839 35 Models F1840 40 Models and F1903 45 Models Follow installation instructions These fireplaces are designed as supplemental heaters and are not to be used as the primary heat source when installed in a dwelling Provide adequate ...

Страница 8: ...é L installation et la réparation devrait être confiées à un technicien qualifié L appareil devrait faire l objet d une inspection par un technicien professionnel avant d être utilisé et au moins une fois l an par la suite Des nettoyages plus fréquents peuvent être nécessaires si les tapis la literie et cetera produisent une quantité importante de pous sière Il est essentiel que les compartiments ...

Страница 9: ...opane 11 0 WC 2 74 kPa 13 0 WC 3 23 kPa Table 4 Manifold Gas Supply Pressure Fuel Pressure Natural Gas 3 5 WC 0 87 kPa Propane 10 0 WC 2 49 kPa Test gauge connections are provided on the front of the millivolt and electronic gas control valve identified IN for the inlet and OUT for the manifold side The control valves have a 3 8 10 mm NPT thread inlet and outlet side of the valve Figure 1 and Figu...

Страница 10: ...assachusetts Rules and Regulations 248 C M R Installation and repair must be done by a plumber or gas fitter licensed in the Commonwealth of Massachusetts The flexible gas line connector used shall not exceed 36 914 mm in length The individual manual shutoff must be a T handle type valve Massachusetts Horizontal Vent Requirements In the Commonwealth of Massachusetts horizontal terminations install...

Страница 11: ...conditioning ducting These direct vent fireplaces are uniquely suited for installations requiring a utility shelf positioned directly above the fireplace Utility shelves like these are commonly used for locating television sets and decorative plants Be aware that this is a heat producing fireplace Objects placed above the unit are exposed to elevated temperatures Do not insulate the space between ...

Страница 12: ...nimum clearance to combustibles Flat to 6 12 1 0 ft 0 3 m 6 12 to 7 12 1 25 ft 0 38 m 7 12 to 8 12 1 5 ft 0 46 m 8 12 to 9 12 2 0 ft 0 61 m 9 12 to 10 12 2 5 ft 0 76 m 10 12 to 11 12 3 25 ft 0 99 m 11 12 to 12 12 4 0 ft 1 22 m 12 12 to 14 12 5 0 ft 1 52 m 14 12 to 16 12 6 0 ft 1 83 m 16 12 to 18 12 7 0 ft 2 13 m 18 12 to 20 12 7 5 ft 2 29 m 20 12 to 21 12 8 0 ft 2 44 m Horizontal Vent Termination ...

Страница 13: ...o inside corner 6 152 mm minimum 6 152 mm minimum H Clearance to each inside of center line extended above meter regulator assembly 36 910 mm within a height of 15 ft above the meter regulator assembly 36 910 mm within a height of 15 ft above the meter regulator assembly I Clearance to service regulator vent outlet 36 910 mm 36 910 mm J Clearance to nonmechanical air supply inlet to building or th...

Страница 14: ...inyl tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance Hearth Extension A hearth extension is not required with this fireplace If a hearth extension is used do not block the lower control compartment door Any hearth extension used is for appearance only and does not have to confo...

Страница 15: ...llowed to encroach the area defined by the fireplace front face black sheet metal Never allow combustible materials to be positioned in front of or overlapping the fireplace face Figure 41 Non combustible materials such as surrounds and other fireplace trim may be installed on the fireplace face but they must not cover any portion of the removable glass panel or control compartment Vertical instal...

Страница 16: ...llation in the Framing Page 38 Gas Connection 14 Connect the Gas Line Page 38 15 Verify Proper Fireplace Operation Page 39 Finishing 16 Optional Install the Firebox Liners Page 53 17 Install the Logs Volcanic Stone and Glowing Embers Page 54 18 Install the Glass Door Page 57 19 Adjust the Air Shutter to Ensure Proper Flame Appearance Page 40 20 Install the Hood Page 42 21 Reinstall the Included Ba...

Страница 17: ...ermination Model A B C D E F B A C Inches millimeters D E Back wall of chase enclosure including finishing materials 7 178 33 33 3 4 857 51 1 4 1302 36 1 4 921 25 5 8 651 12 1 8 308 5 1 2 140 35 35 3 8 899 59 1 2 1511 42 1 16 1068 30 1 4 768 14 1 4 362 6 5 8 168 40 40 3 8 1025 63 13 16 1621 45 11 32 1152 33 3 16 818 15 7 8 403 8 1 2 216 45 45 3 8 1153 70 3 8 1788 49 3 4 1264 35 1 4 895 17 1 2 445 ...

Страница 18: ... regulator to the area where the appliance is to be installed per requirements outlined in the National Fuel Gas Code NFPA 54 latest edition USA or CAN CGA B149 1 latest edition Canada The gas supply line should not be connected to the appliance until step 12 Connect the Gas Line Page 38 NOTE All fireplaces are factory equipped with a flexible gas line connector and 1 2 shutoff valve Figure 35 See...

Страница 19: ...o the buildup of heat Standoff arrives on the lower front of the unit Step 1 Remove the eight 8 screws holding the top vent cover plate and gasket Step 2 Remove the round flue cover from the top venting outlet Step 3 Remove insulation from inside flue pipe Step 4 Make sure insulation disc is still in the round cover Remove the flue plug from the top flue Step 5 Bend tabs out on round flue cover Se...

Страница 20: ...may be in direct contact with the nailing flanges and may be located within 1 2 of screw heads and the firebox wrapper in areas adjacent to the nailing flanges Frame the opening to the exact dimensions specified in the framing details in this manual 1 Bend out the appropriate nailing flanges for the drywall finish material to be used Figure 11 Nailing flanges are provided for flush framing 1 2 and...

Страница 21: ...nner Fireplace Collar Appliance Rear Vent Outlet U Shaped Vent Restrictor Intake Air Baffle Base Vent Restrictor Base Vent Restrictor Wing With break away raised Inner Fireplace Collar Appliance Rear Vent Outlet U Shaped Vent Restrictor Intake Air Baffle Figure 15 Vent restrictor assembly U Shaped Vent Restrictor Inner Fireplace Collar Appliance Top Vent Outlet U SHAPED VENT RESTRICTOR APPLIANCE R...

Страница 22: ...e 3 If desired a 6 x 1 2 screw can be used at the joint but is not required as the pipe will securely lock when twisted Figure 17 Where required a telescopic vent section SV4 5LA may be used to provide the installer with an option to install in tight and confined spaces or where the vent run made up of fixed length pieces develops a joint in a undesirable location or will not build up to the requi...

Страница 23: ...3 0 0 3 465 38 75 0 0 0 0 10 10 69 5 75 0 0 0 2 0 2 475 5 39 625 0 1 0 0 10 11 73 5 6 125 1 0 0 2 0 3 480 40 1 1 0 0 10 12 79 5 6 625 0 1 0 2 0 3 492 41 1 0 1 0 10 12 81 6 75 0 0 0 1 1 2 499 5 41 625 0 0 0 1 10 11 91 5 7 625 0 0 2 0 1 3 504 42 1 0 0 1 10 12 93 7 75 0 0 0 0 2 2 511 5 42 625 0 0 0 0 11 11 97 5 8 125 1 0 0 0 2 3 520 5 43 375 0 2 0 1 11 14 103 5 8 625 0 0 0 3 0 3 531 44 25 0 2 2 0 11 ...

Страница 24: ...alls is specified in ANSI Z223 1 In Canada the current CAN CGA B149 1 installation code by major building codes Always consult your local codes for specific requirements A general guide to follow is the gas vent rule Table 6 The following figures and their associated vertical vent tables illustrate the various configurations that are possible for use with these fireplaces Secure Vent pipe is shown...

Страница 25: ... 22 6 Install firestop spacer at ceiling When using Secure Vent use SV4 5VF firestop spacer at ceiling joists when using Secure Flex use SF4 5VF firestop spacer If there is living space above the ceiling level the firestop spacer must be installed on the bottom side of the ceiling If attic space is above the ceiling the firestop spacer must be installed on the top side of the joist Route the vent ...

Страница 26: ...at top and sides only and trim where necessary Seal the top and both sides of the flashing with waterproof caulking 12 Install the storm collar Install the storm collar supplied with the flashing over the vent flashing joint Figure 23 Loosen the storm collar screw Slide collar down until it meets the top of the flashing Tighten the adjusting screw Apply non combustible caulking or mastic around th...

Страница 27: ...sed WARNING Do NOT join separate sections of concentric flexible vent pipe Figure 25 Top Vent Straight Table 16 Rear Vent One 90 Elbow Ceiling firestop spacer SV4 5VF When using Secure Flex use ceiling firestop spacer SF4 5VF 60 ft 18 3 m maximum Ceiling firestop spacer SV4 5VF When using Secure Flex use ceiling firestop spacer SF4 5VF H V H Maximum V Minimum feet meters feet meters 2 0 610 1 0 30...

Страница 28: ...r in any vent run with more than 6 ft of vertical rise See Page 21 for more information If 20 ft of H horizontal vent run is needed then 4 ft straight section minimum of V vertical vent will be required This table shows a 1 V to 5 H ratio For every 1 ft of V vertical you are allowed 5 ft of H horizontal run up to a maximum horizontal run of 20 ft NOTE The vent system may have a maximum of three 3 ...

Страница 29: ...he minimum clearances for combustibles Page 15 2 Frame the exterior wall opening Locate the center of the vent outlet on the exterior wall Table 11 Cut and or frame an opening 10 1 2 x 12 1 8 267 x 308 mm inside dimensions about this center 3 Frame the ceiling opening If the vertical route is to penetrate a ceiling use plumb line to locate the center above the fireplace Cut and or frame an opening...

Страница 30: ... SV4 5RCH provided with the termination to the vent section or telescoping vent section elbow or fireplace collar Figure 27 13 Install the firestop spacer at the exterior wall When using the square termination install SV4 5HF Secure Vent SF4 5HF Secure Flex Firestop Spacer over the opening at the exterior side of the framing long side up with the 3 spacer clearance at the top Figure 27 and nail in...

Страница 31: ...er infiltration install the firestop spacer SV4 5HF on the exterior side of the wall The firestop may be caulked with mill base caulk such as 10K81 or high temperature silicone Figure 28 Venting Connection and Exterior Wall Recessing of the Horizontal Compact Termination 94L10 Siding Stucco 1 1 4 Maximum Recess of the Square Termination into Exterior Finishing Material Exterior Surface of Framing ...

Страница 32: ...pacer must be used any time vent pipe passes through a combustible floor or ceiling SV4 5HF Secure Vent SF4 5HF Secure Flex firestop spacer must be used any time vent pipe passes through a combustible wall WARNING Do not join separate sections of concentric flexible vent together Table 21 Rear Vent No Elbows See Table 21 as an aid in venting component selection for a particular range of exterior w...

Страница 33: ...610 15 4 572 6 1 829 3 0 914 25 7 62 10 3 048 5 1 524 V H H1 60 ft 18 288 m maximum H 8 ft 2 438 m maximum H H1 25 ft 7 62 m maximum Install the U shaped vent restrictor in any vent run with more than 4 ft of vertical rise See Page 21 for more information See Table 21 as an aid in venting component selection for a particular range of exterior wall thicknesses If 25 ft of H horizontal vent run is n...

Страница 34: ... required This table shows a 1 V to 5 H ratio For every 1 ft of V vertical you are allowed 5 ft of H horizontal run up to a maximum horizontal run of 20 ft 6 096 m Table 27 Top Vent Three 90 Elbows H Maximum V Minimum When using Secure Flex use Ceiling Firestop Spacer SF4 5VF When using Secure Flex use Wall Firestop Spacer SF4 5HF Ceiling Firestop Spacer SV4 5VF Wall Firestop Spacer SV4 5HF V H V1...

Страница 35: ...daptor Figure 30 Flexible Vent Apply ONLY MIL PAC BLACK HIGH TEMPERATURE SEALANT P N 10K81 to the outside surface of both collars of the adaptor fill the grooves of the outer collar to be covered by the flexible pipe and slide the flexible vent over the inner and outer adaptor collars NOTE Outer vent pipe is pulled away to show inner vent pipe details 1 3 4 44 mm flexible vent and adaptor outer co...

Страница 36: ...OTE Attach Secure Flex vent to Secure Flex terminations only Do NOT substitute Secure Vent terminations or Secure Vent adaptor for Secure Flex components Secure Flex termination and adaptor collars are a different circumference than Secure Vent collars Secure Flex vent has an longer center tube to improve ease of installation 11 Complete the Field Wiring CAUTION The ground supply lead must be conn...

Страница 37: ...N STANDING PILOT MODE DFS WIRE HARNESS PILOT GROUND WIRE SPARK WIRE CABLE PILOT TUBE FLAME SENSOR PILOT SENSOR CABLE AC DC POWER ADAPTOR JUNCTION BOX 120V AC HOT NEUTRAL GROUND B BL 2B 1B 2A 2 1 1A R O B 1 2 G W BL BL O O R R G W B B W G R W B Y G O G W R BL B BL W G G Y O Y B B B R B Electronic Wiring One of the following optional controls must be used ON OFF Wall Switch Thermostat or Remote Cont...

Страница 38: ...ion of the FBK 100 FBK 200 and FBK 300 forced air blower kits Electrical power must be provided to the box to operate the blower Install the blower kit according to the installation instructions provided with the kit NOTE The tab connecting the receptacles of the outlet box must be broken in FBK 100 and FBK 200 blower kit applications Figure 34 Figure 32 Junction Box Wiring 120 V 60 hz 1 phase Fig...

Страница 39: ... line holes and other openings can be caulked or stuffed with unfaced fiberglass insulation All codes require a shutoff valve mounted in the supply line The orientation of the shutoff valve should face the front Figure 35 illustrates two methods for connecting the gas supply A sediment trap is recommended to prevent moisture and debris in the gas line from damaging the valve Test Factory and Field...

Страница 40: ...7 Figure 36 Millivolt Pilot Figure 37 Electronic Pilot Thermocouple Hood Igniter rod 3 8 9 mm min Thermopile Pilot nozzels Igniter Flame Rod Pilot Hood 15 Optional Install the Firebox Liners 1 See Page 53 for instructions on Traditional Only Installing the Firebox Liners 16 Traditional Fireplaces Install the Logs Volcanic Stone and Glowing Embers 1 See Page 54 for instructions on Installing the lo...

Страница 41: ...c Propane models may exhibit flames that candle or appear stringy If this condition is present and persists adjust the air shutter to a more closed position then operate the fireplace for a few more minutes to ensure that the flame normalizes and the flames do not appear sooty The following chart is provided to help achieve the correct air shutter adjustment for your installation Table 28 Air Shut...

Страница 42: ...ial over the black surface above the fireplace opening the bottom edge of the finish material must be 5 8 above the top edge of the hood to allow clearance for installation and removal of the hood 20 Reinstall the Included Barrier WARNING Reinstall any barrier removed before operating the fireplace The barrier is designed to reduce the risk of burns from hot glass Do not operate the fireplace with...

Страница 43: ... 22 Attach the Safety in Operation Warning Labels 1 Attach the furnished safety instruction labels at all fireplace operation and control points Page 44 NOTE The installer MUST ensure these warnings are properly attached during installation The warning labels are a critical means of informing consumers of safe operation practices 23 Installing Batteries for Backup and Wall Switch 1 Locate the batt...

Страница 44: ...imarily spoken in the home If unknown affix the English language label 3 If you are unable to locate the labels please contact IHP or your nearest IHP dealer to receive additional safety instruction labels free of charge 1 Repérez l interrupteur ou le thermostat mural qui contrôle le foyer vérifiez que l interrupteur contrôle le fonctionnement du foyer en le faisant basculer de Marche à Arrêt et v...

Страница 45: ...it HT 2 with 90 elbow H2246 SV4 5HF 10 Firestop Spacer Horizontal rigid 3 1 1 spacing 10 Pack H8915 SV4 5TK90SS Horizontal Termination Kit Small Square with 90 elbow H2247 SV4 5VF 10 Firestop Spacer Vertical rigid 1 1 1 spacing 10 Pack 96K92 SV4 5SP Support Plate Vent Sections Rigid 77L70 SV4 5L6 6 152 mm 17M52 SV4 5HGS 1 Termination Guard Square 1 pack see 750109M 77L71 SV4 5L12 12 305 mm 77L72 S...

Страница 46: ...4 610 mm of compressed flex vent see 750204M H2249 SF4 5VF 10 Firestop Spacer Vertical flex 1 1 1 spacing 10 Pack 94L07 SFKIT36SS Small Square Termination for flex with 36 914 mm of compressed flex vent see 750204M H1969 SF4 5HT 2 Horizontal Square Termination for flex without flex 56L74 SFVT30 VerticalTerminationforflex flatto6 12 with flexadaptor sectionofrigidvent roofsupport collarassembly roo...

Страница 47: ...pas adéquate ni complète tant que le bon fonctionnement de l appareil converti n a pas été vérifié selon les instructions du fabricant fournies avec la trousse Le fournisseur de service qualifié ayant réalisé l installation assume les responsabilités liées à la conversion In Canada The conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdic...

Страница 48: ...em Fireplaces 7 Refer to the instructions provided with the SIT Regulator Conversion Kit and Figure 42 Using a Torx T20 driver with 1 4 shank or slotted screwdriver remove and discard the pressure regulator mounting screws two screws for electronic models three screws for millivolt models pressure regulator tower the diaphragm assembly if applicable and the spring Discard all removed components Fi...

Страница 49: ...8 Set the burner assembly into its position and secure the trapezoidal plate with the two screws previously removed 14 Reinstall the baffle with the two baffle securing screws 15 Reassemble the remaining components 16 Turn on gas supply and test for gas leaks Page 39 17 Relight the main burner The lighting instructions can be found on the lighting label in the control compartment or Page 65 Verify...

Страница 50: ...cted by carbon monoxide than others including pregnant women people with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes NOTE Do not place furniture or other combustible materials within 36 of the front of viewing area s NOTE Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or cloth...

Страница 51: ...en in the home If unknown affix the English language label 3 If you are unable to locate the labels please contact IHP or your nearest IHP dealer to receive additional safety instruction labels free of charge 1 Repérez l interrupteur ou le thermostat mural qui contrôle le foyer vérifiez que l interrupteur contrôle le fonctionnement du foyer en le faisant basculer de Marche à Arrêt et vice versa Ne...

Страница 52: ...trol compartment securing the control compartment door Retain the screw for later reinstallation 2 Position the left side door tab Figure 45 out of the tab groove and align it with the vertical slot Figure 44 Figure 44 Control compartment door slots Figure 45 Control compartment door tabs Vertical slot Screw hole Tab pivot hole Tab groove Door tabs 3 Lift the left side of the control compartment d...

Страница 53: ...ly switch to battery power In the event of a power outage this allows ON OFF operation without blower functionality Install new batteries before every burn season 1 Open the control compartment Page 52 and locate the battery holder 2 Install four 4 AA batteries in the battery holder 3 Close the control compartment door Continuous Pilot Ignition Switch Fireplaces with an electronic gas valve have a...

Страница 54: ... according to these instructions improper combustion could occur This could result in the excessive production of soot and or the colorless odorless toxic gas carbon monoxide CO NOTE If applicable install the firebox liner before placing the stone Logs can be installed after the volcanic stone Installing the volcanic stone and glowing embers 1 If necessary remove the glass door Page 57 2 Spread th...

Страница 55: ...s Log 5 Right Cross Log Catalog number for the entire set 33 F1830 35 F1884 1 If necessary remove the glass door Page Locate and bend up Burner Locating Tabs Figure 50 2 Locate the log placement brackets Figure 50 Place embers and other media see Page 51 Figure 49 Locating the log placement brackets Figure 50 Placing log 1 and 2 Left Log Bracket front rear Right Log Bracket front rear Left and Rig...

Страница 56: ...atalog number for the entire set 40 F1830 45 F1884 1 If necessary remove the glass door Page 57 2 Locate the log placement brackets Figure 54 Figure 53 Placing log 1 Figure 54 Placing logs 2 and 3 Glowing Embers Do not place glowing embers over burner slots Right Rear Log Bracket 1 Volcanic Stone Log Rack 3 2 3 Position rear log 1 on the left rear log bracket Figure 54 4 Position the left front lo...

Страница 57: ...o reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed WARNING Une barrière conçue pour réduire le risque de brûlure par le hublot chaude est fournie avec l appareil et doit être installé WARNING Do not operate appliance with the glass front removed cracked or broken AVERTISSEMENT Ne pas utiliser l appareil si le panneau frontal en verre n est ...

Страница 58: ...ket seats evenly as the door draws shut Securely fasten the two 2 latches beneath the firebox floor to the door V flange 4 Install the barrier 5 Close the control compartment door Removing the glass door 1 Open the control compartment door Page 52 NOTE If necessary remove the door and place it in a safe location for later reinstallation 2 Remove the barrier Place the barrier in a safe location for...

Страница 59: ... venting system components However more frequent periodic inspections and cleanings should be performed by the homeowner NOTE Prior to the first use of the fireplace and each burn season and periodically during the burn season inspect the horizontal termination for debris such as bird nests leaves paper or branches Remove any items from the surfaces of the termination prior to use Also be aware of...

Страница 60: ... e g paint brush Reinstalling the embers and logs Carefully follow the placement instructions Page 54 All logs should fit onto the corresponding pins and or log stoppers This will ensure proper flame and safe combustion NOTE Improper positioning of logs can create carbon build up and will alter the performance of the fireplace Replacing the logs If the logs become damaged and need replacement use ...

Страница 61: ...ion Look for any signs of dislocation of the vent components Fireplace Inspection Qualified Service Technician Perform the appropriate fireplace inspection procedure detailed in this manual Replacing Glowing Embers Homeowner Qualified Services Technician Remove the old glowing embers and vacuum the area Place new glowing embers Figure 48 Replacing Batteries Homeowner Qualified Services Technician ...

Страница 62: ...ermostatically Table 41 Forced Air Kits Catalog Model Description 80L84 FBK 100 Blower Standard single speed 80L85 FBK 200 Blower Variable Speed with wall mounted switch H7841 FBK 250 Blower Variable Speed with thermal snap switch Glowing Embers and Volcanic Stone Table 42 Glowing Embers and Volcanic Stone Catalog Model Description 88L53 FGE Bag of Glowing Embers 80L42 FDVS Bag of Volcanic Stone B...

Страница 63: ... control with touch screen operation Catalog Number Backlit LCD display Transmitter wall mounted docking station Receiver wall mounted or placed in the control compartment Thermostatic or manual ON OFF operation Programmable weekday weekend modes Flame icon Low battery indicator Batteries included H8865 WS S STAT Wall control Catalog Number Large LCD display Shows room and set temperatures in F an...

Страница 64: ... OFF operation in lieu of a wall switch Table 47 Unit Mountable Rocker Switch Catalog Model 80L41 FRS OFF ON Wall Switch Kit The OFF ON wall switch kit can be used to control the operation of the fireplace burner or blower Install the OFF ON wall switch in a convenient location near the fireplace Table 48 OFF ON Wall Switch Kit Catalog Model 85L87 FWSK Variable Speed Wall Switch Kit The variable s...

Страница 65: ... immediately call your service technician or gas supplier LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE If the pilot will not stay lit after several tries turn the gas control knob to OFF and call your service technician or gas supplier 10 Turn gas control knob counterclockwise to ON 11 Close control compartment 12 If applicable Turn on all electrical power to the appliance 13 If applicable S...

Страница 66: ...chnicien qualifié ou le fournisseur de gaz Si la veilleuse ne reste pas allumée après plusieurs tentatives réglez la manette d admission du gaz à la position OFF et appelez un technicien qualifié ou le fournisseur de gaz 10 Tournez le bouton de réglage du gaz en sens inverse des aiguilles d une montre jusqu à sa position de marche ON 11 Fermer le compartiment de contrôle 12 Si applicable Mettez l ...

Страница 67: ... control which has been under water Electronic Gas Control Valve SIT Electronic Pilot Assembly 3 Turn off all electric power to the appliance if service is to be performed Note The control may have a battery backup remove batteries if installed 4 Close the main line gas shut off valve 1 STOP Read the safety information above on this label 2 Read the Care and Operation manual including the section ...

Страница 68: ...batterie de secours installer les batteries au besoin 8 Placez l interrupteur du récepteur en position REMOTE ou l interrupteur mural en position ON 9 Si applicable Appuyez sur le bouton ON OFF pour sélectionner ON 10 Si applicable Ajustez le thermostat sur la télécommande à l ajustement désiré 11 Si l appareil ne se met pas en marche suivez les instructions intitulées Comment couper l admission d...

Страница 69: ...structions a Defective pilot generator thermocouple Check pilot flame it must impinge on thermocouple Clean and or adjust pilot for maximum flame impingement on thermocouple Ensure that the connection between the valve and thermocouple are tight and secure 3 Pilot burning no gas to burner Valve knob ON and the standard burner OFF ON switch is ON NOTE If an optional remote switch is used for burner...

Страница 70: ...alves b Loose wires to the valve or ignition module Check control compartment for any obviously loose wiring call a service technician if necessary c Pilot flame is not engulfing the sensor Call a service technician d Obstructed vent system Call a service technician 4 Soot is present on the logs and glass a Excessive flame impingement on the logs Properly position the logs as detailed on Page 54 b...

Страница 71: ...ivolt Thermocouple 74L57 1 74L57 1 74L57 1 74L57 1 15 Millivolt Pilot Tube 74L56 1 74L56 1 74L56 1 74L56 1 16 MIllivolt Electrode and Cable H6212 1 H6212 1 H6212 1 H6212 1 17 Orifice Holder H7257 1 H7257 1 H7257 1 H7257 1 18 Gas Flex Line Connector 93L32 1 93L32 1 93L32 1 93L32 1 19 Gas Valve Electronic Natural Gas H6209 1 H6209 1 H6209 1 H6209 1 20 Gas Valve Electronic Liquid Propane 88J53 1 88J5...

Страница 72: ...s conformément à ces schémas et ou si des pièces autres que celles spécifiquement approuvées avec cet appareil sont utilisées Table 53 Homeowner Replacement Parts Description 33 Models 35 Models 40 Models 45 Models Catalog Number Catalog Number Catalog Number Qty Catalog Number Qty Catalog Number Qty 38 Hood F1900 1 F1837 1 F1838 1 F1901 1 39 Barrier F1902 1 F1839 1 F1840 1 F1903 1 40 Glass Door F...

Страница 73: ...jected to normal use The Product is designed to burn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damage...

Страница 74: ...s and products Consult your local distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products LLC P N 900285 00 Rev B 11 2014 1508 Elm Hill Pike Suite 108 Nashville TN 37210 Contact an IHP dealer to obtain any of these parts Please contact IHP for the phone number of your nearest IHP dealer SuperiorFireplaces us com Record the following important information about y...

Отзывы: