background image

Superiorfireplaces.US.com

126718-01_D

4

Important Safety Informa-

tion

1. WARNING: Do not operate appliance 

with the glass front removed, cracked, 
or broken. 

2. Do not use this appliance if any part 

has been under water. Immediately 
call a qualified service technician to 
inspect the appliance and to replace 
any part of the control system and 
any gas control which has been under 
water.

3. Due to high temperatures, the appli-

ance should be located out of traffic 
and away from furniture and draperies.

4. Children and adults should be alerted 

to the hazards of high surface tem-
perature and should stay away to avoid 
burns or clothing ignition. 

5. Clothing or other flammable material 

should not be placed on or near the 
appliance.

6. Young children should be carefully 

supervised when they are in the same 
room as the appliance. Toddlers, 
young children, and others may be sus-
ceptible to accidental contact burns. 
A physical barrier is recommended 
if there are at-risk individuals in the 
house. To restrict access to a fireplace 
or stove, install an adjustable safety 
gate to keep toddlers, young children, 
and other at-risk individuals out of the 
room and away from hot surfaces.

7. Any safety screen, guard or barrier 

removed for servicing an appliance 
must be replaced prior to operating 
the appliance.

8. Installation and repair should be done 

by a qualified service person. The 
appliance should be inspected before 
use and at least annually by a profes-
sional service person. More frequent 
cleaning may be required due to 
excessive lint from carpeting, bedding 
material, et cetera. It is imperative 
that control compartments, burners, 
and circulating air passageways of the 
appliance be kept clean. See mainte-
nance instructions on 

Page 35

.

L’information de sûreté 

importante

1.  AVERTISSEMENT. Ne pas utiliser l’appareil 

si le panneau frontal en verre n’est pas en 

place, est craqué ou brisé. 

2.  Ne pas se servir de cet appareil s’il a été 

plongé dans l’eau, même partiellement. 

Faire inspecter l'appareil par un technicien 

qualifié et remplacer toute partie du systéme 

de contrôle et toute commande qui ont été 

plongées dans l'eau.

3.  En raison des températures élevées, 

l’appareil devrait être installé dans un 

endroit où il y a peu de circulation et loin 

du mobilier et des tentures.

4.  Les enfants et les adultes devraient être 

informés des dangers que posent les tem-

pératures de surface élevées et se tenir à 

distance afin d’éviter des brûlures ou que 

leurs vêtements ne s’enflamment.

5.  On ne devrait pas placer de vêtements 

ni d’autres matières inflammables sur 

l’appareil ni à proximité.

6.  Les jeunes enfants devraient être surveillés 

étroitement lorsqu’ils se trouvent dans la 

même pièce que l’appareil. Les tout petits, 

les jeunes enfants ou les adultes peuvent 

subir des brûlures s’ils viennent en contact 

avec la surface chaude. Il est recommandé 

d’installer une barrière physique si des 

personnes à risques habitent la maison. 

Pour empêcher l’accès à un foyer ou à un 

poêle, installez une barrière de sécurité 

;  cette  mesure  empêchera  les  tout  petits, 

les jeunes enfants et toute autre personne 

à risque d’avoir accès à la pièce et aux 

surfaces chaudes.

7.  Tout écran ou protecteur retiré pour per-

mettre l’entretien de l’appareil doit être 

remis en place avant de mettre l’appareil 

en marche.

8.  L’installation et la réparation devrait être 

confiées à un technicien qualifié. L’appareil 

devrait faire l’objet d’une inspection par un 

technicien professionnel avant d’être utilisé 

et au moins une fois l’an par la suite. Des 

nettoyages plus fréquents peuvent être 

nécessaires si les tapis, la literie, et cetera 

produisent une quantité importante de pous-

sière. Il est essentiel que les compartiments 

abritant les commandes, les brûleurs et les 

conduits de circulation d’air de l’appareil 

soient tenus propres. Voyez les instructions 

d’entretien à la 

Page 35

.

Información importante de 

seguridad

1.  ADVERTENCIA: No opere el artefacto con el 

frente de vidrio quitado, agrietado o roto.  

2.  No use este artefacto si alguna de sus partes 

ha estado bajo agua. Llame de inmediato 
a un técnico de servicio calificado para 
que inspeccione el artefacto y reemplace 
cualquier parte del sistema de control y 
cualquier control de gas que haya estado 
bajo agua.

3.  Debido a las altas temperaturas, el artefacto 

debe situarse fuera de las áreas de tráfico y 
lejos del mobiliario y cortinas.

4.  Se debe alertar a los niños y adultos sobre 

los peligros de las altas temperaturas en la 
superficie y que se mantengan alejados para 
evitar quemaduras o ignición de la ropa. 

5.  No debe colocarse ropa u otros materiales 

inflamables sobre y cerca del artefacto.

6.  Se debe supervisar de cerca a los niños 

cuando estén en el mismo cuarto que el 
artefacto. Los niños pequeños, los jóvenes 
y otras personas pueden ser susceptibles 
a quemaduras por contacto accidental. Se 
recomienda instalar una barrera física si hay 
personas en riesgo en la casa. Para restringir 
el acceso a una chimenea o estufa, instale 
una puerta de seguridad ajustable para 
mantener a los niños pequeños, jóvenes y 
otras personas en riesgo fuera del cuarto y 
lejos de las superficies calientes.

7.  Cualquier malla o resguardo de seguridad 

quitado para dar servicio a un artefacto, debe 
reinstalarse antes de operar el artefacto.

8.  Una persona de servicio competente debe 

realizar la instalación y reparación. Una 
persona de servicio profesional debe 
inspeccionar el artefacto antes de usar al 
menos una vez por año. Se puede requerir 
limpieza más frecuente debido a la pelusa 
excesiva del alfombrado, del material de 
cobijas, etc. Es imprescindible mantener 
limpios los compartimientos de control, los 
quemadores y los pasajes de circulación del 
aire del artefacto. Ver las instrucciones de 
mantenimiento en la 

página 35

.

IMPORTANT SAFETY INFORMATION

Содержание DRL4543TEN

Страница 1: ...icinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immedia...

Страница 2: ...MADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas de contact accidentel avec la vitr...

Страница 3: ...famille soient conscients du danger de br lure encouru Les surfaces de votre foyer deviennent EXTR MEMENT CHAUDES La vitre situ e l avant du foyer atteint des temp ratures EXTR MEMENT LEV ES et peut...

Страница 4: ...s viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une bar...

Страница 5: ...young children and other at risk individuals out of the room and away from hot surfaces This vented gas fireplace is a sealed combustion gas fireplace de signed for residential applications This firep...

Страница 6: ...uard or barrier removed for servicing an appliance must be replaced prior to operating the appliance SAFETY Continued Installation and repair should be done by a qualified service person The appliance...

Страница 7: ...NFPA 54 USA or the current CSA B149 1 Installation Code Canada Available from American National Standards Institute Inc 25 West 43rd Street 4th floor New York NY 10036 National Fire Protection Associa...

Страница 8: ...MONWEALTH OF MASSACHUSETTS Massachusetts Horizontal Vent Requirements In the Commonwealth of Massachusetts horizontal terminations installed less than seven 7 feet above the finished grade must comply...

Страница 9: ...t Do not locate termination cap and outside air vent where excessive snow or ice build up may occur Be sure to clear vent termination area after snow falls to prevent accidental blockage of venting sy...

Страница 10: ...tible Material May Be Used TOP VIEW SAFE ZONE Perpendicular Wall 33 4 to Face Opening 5 53 1 4 1353 mm 53 1 4 1353 mm 38 965 mm 38 965 mm STUDS MOUNTED FLAT INSIDE OF NAILING FLANGE 15 1 4 387 mm MOUN...

Страница 11: ...m 16 1 2 419 mm 8 1 4 210 mm 29 7 8 759 mm 29 7 8 759 mm 3 1 2 89 mm 16 3 8 416 mm 7 1 8 181 mm 1 7 8 48 mm 8 1 4 210 mm 4 1 8 105 mm 44 1 8 1121 mm 55 1 8 1400 mm 47 1194 mm 1 25 mm 1 25 mm 52 1321 m...

Страница 12: ...en 10 000 and 50 000 12 30 cm in Canada if between 10 000 and 100 000 12 30 cm in US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In C...

Страница 13: ...estops when penetrating ceilings or attic spaces For installation of fireplace at elevations of 4000 feet or greater pay special attention to venting requirement recommendations WARNING Read all instr...

Страница 14: ...rate a ceiling use plumb line to locate the center above the fireplace Cut and or frame an opening 10 1 2 x 10 1 2 267 x 267 mm inside dimensions about this center Figure 17 page 19 4 Attach the vent...

Страница 15: ...he firestop spacer may also be installed over the opening at the interior side of the framing 13 Install the termination SV4 5HTKCT From outside the exterior wall slide the collars of the termination...

Страница 16: ...silicone caulking to seal the top and sides of the termination up to the underlayment stucco or masonry wall surface Caulk Caulk NOTE See table 1 for wall thickness ranges when using SV4 5HTKCT termin...

Страница 17: ...seal both the inner and outer vent pipe 3 If desired a 6 x 1 2 screw can be used at the joint but is not required as the pipe will securely lock when twisted Figure 12 Figure 11 Connecting vent compon...

Страница 18: ...op spacer SF4 5VF When using Secure Flex use wall firestop spacer SF4 5HF Wall firestop spacer SV4 5HF Ceiling firestop spacer SV4 5VF H V H1 V1 VENTING INSTALLATION Continued V Vertical Minimum Requi...

Страница 19: ...Frame the ceiling opening Use a plumb line from the ceil ing above the fireplace to locate the center of the vertical run Cut and or frame an opening 10 1 2 x 10 1 2 267 x 267 mm inside dimensions abo...

Страница 20: ...oof flashing over the vent sec tion and position such that the vent column rises vertically use carpenters level Nail along perimeter to secure flashing or adjust roofing to overlap the flashing edges...

Страница 21: ...west discharge opening H H minimum height from roof to lowest discharge opening of vent Horizontal overhang Vertical wall Vent termination Storm collar Concentric vent pipe Flashing 1 26 mm minimum cl...

Страница 22: ...OR VENTING KITS AND COMPONENTS Table 3 Listed Components Listed Secure Flex Components Continued F1801 SFKIT36CT Compact Termination for flex with 36 914 mm compressed flex F1802 SFKIT48CT Compact Ter...

Страница 23: ...vent 4 Slide the inner flex vent over the adaptor collar at least 1 3 4 5 NOTE Ensure the flex vent is free from damage or tears 6 Slide the gear clamp down and tighten it fully to secure the flexible...

Страница 24: ...ified service person must con nect fireplace to gas supply Follow all local codes CAUTION For propane LP units never connect fireplace directly to the propane LP supply This heater requires an externa...

Страница 25: ...ply line as shown in Figure 28 Locate sediment trap drip leg where it is within reach for cleaning Install in piping system between fuel supply and fireplace Locate sediment trap drip leg where trappe...

Страница 26: ...eplace or using compressed air 3 Check all joints from propane LP supply tank or gas meter to equipment shutoff valve see Figure 31 or Figure 32 Apply noncorrosive leak detection fluid to all joints B...

Страница 27: ...x using your fingers or the latch opener provided 3 Hook opener over latch as shown in Figure 34 Swing the bot tom of the opener down toward the door You will not need to pull down 4 Tilt open glass d...

Страница 28: ...embers to refresh the ember bed during annual maintenance Reinstall the included barrier J7457 WARNING Reinstall any barrier removed before operating the fireplace The barrier is designed to reduce th...

Страница 29: ...g Replacing Glass Door page 27 of this manual Installing Access Door Retaining Brackets 1 Screw access door retaining brackets into the inner side face using 2 screws on both the left and right side a...

Страница 30: ...use only non combustible materials You may extend up to the edge of the exterior door covering up the screws used for installation Installing Outdoor Barrier F2253 1 Using a flat head screwdriver pop...

Страница 31: ...nterrupteur mural qui contr le le foyer Figure A ou du thermostat mural Figure B Choisissez la langue qui est principalement parl e dans la r sidence du propri taire En cas de doute collez l tiquette...

Страница 32: ...nge flamewillalsobepresent Openwindowtoventsmell This will only last a few hours 1 STOP Read the safety information in column 1 2 Turn off all electric power to fireplace 3 Turn safety shutoff switch...

Страница 33: ...a Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrola la chimenea Figura A o en el termostato de pared Figura...

Страница 34: ...e entire flame may be blue and will gradually turn yellow orange during the first 15 minutes of operation If the flame remains blue or if the flame is orange with evidence of sooting black tip the air...

Страница 35: ...rom glass If glass has been broken carefully remove glass door see Remov ing Replacing Glass Door page 27 Vacuum all glass pieces with a shop vacuum CAUTION Do not vacuum if pieces are hot Use only gl...

Страница 36: ...rammed to the Remote Control transmitter To program the module make sure the system has power locate the learn button on left side as shown in Figure 50 Press and release the learn button There will b...

Страница 37: ...order above by pressing the MODE Zone or the MODE SET Button MANUAL OFF MODE Transmits flame OFF command LCD Displays MODE Zone OFF is displaye ROOM TEMP Zone Measured temperature is displayed SET TEM...

Страница 38: ...OCK icon will appear in the MODE Zone If any touch zone or button is pressed when activated the LCD backlight will illuminate and the LOCK icon will flash for 5 seconds in the MODE Zone SENSOR SAFETY...

Страница 39: ...tor 110V MAX 15 AMPS 110V MAX 15 AMPS To Rocker Switch To J Box Pilot Main HI LO DC Motor Drive J7860 Light Module J7865 J7864 J7868 Black Brown Red Orange Orange Green To Ground BATTERY PACK Black Bl...

Страница 40: ...y other possible obstructions 4 Contact your gas supplier to check pres sure 5 Have a qualified technician replace pilot line 6 Replace control valve Refer to Parts page 43 7 Checkthatmainpowerisonand...

Страница 41: ...nfiguration 1 Air holes at burner inlet blocked 2 Burner flame holes blocked 3 Improper venting or excessive blockage OBSERVED PROBLEM Gas odor even when gas control valve is off Gas odor during combu...

Страница 42: ...2 3 1 4 4 5 7 8 9 10 12 13 14 15 16 18 17 19 20 11 6 4 4 PARTS BURNER ASSEMBLY This list contains replaceable parts used in your fireplace When ordering parts follow the instructions listed under Rep...

Страница 43: ...11 J7852 Flextube 1 12 J7853 Burner Gasket 2 13 J7854 Power Module 1 14 J7855 Battery Backup 1 15 J7856 Battery Backup Bracket 1 16 J7857 Valve Bracket 1 17 J7858 Valve NG 1 J7859 Valve LP 1 18 J7860...

Страница 44: ...Superiorfireplaces US com 126718 01_D 44 1 2 3 6 7 7 9 4 12 11 14 13 10 15 8 5 16 17 18 19 21 20 PARTS MODELS DRL4543TEN AND DRL4543TEP...

Страница 45: ...ng Bracket 2 11 J7883 Ceramic Door Assembly 1 12 J7884 Cover Assembly Mesh Linear DV 1 13 J7885 Corner Bracket 4 14 J7886 Side Walls 2 15 J7887 Pebble Pan 1 16 J7888 Rear Wall 1 17 J7889 Rail Barrier...

Страница 46: ...ville TN 37210 Visit us at Superiorfireplaces US com SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition fireplace will not produce specified heat pro...

Страница 47: ...urn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a f...

Страница 48: ...ealer name P126718 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and produ...

Отзывы: